IEEE8021-PB-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE FROM SNMPv2-SMI TruthValue, RowStatus FROM SNMPv2-TC ieee802dot1mibs, IEEE8021PbbComponentIdentifierOrZero, IEEE8021PbbComponentIdentifier, IEEE8021BridgePortNumber, IEEE8021PortAcceptableFrameTypes, IEEE8021PriorityValue, IEEE8021BridgePortNumberOrZero, IEEE8021BridgePortType FROM IEEE8021-TC-MIB ieee8021BridgeBasePortComponentId, ieee8021BridgeBasePort FROM IEEE8021-BRIDGE-MIB VlanId, VlanIdOrNone FROM Q-BRIDGE-MIB MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF; ieee8021PbMib MODULE-IDENTITY LAST-UPDATED "201202100000Z" -- February 10, 2012 ORGANIZATION "IEEE 802.1 Working Group" CONTACT-INFO " WG-URL: http://grouper.ieee.org/groups/802/1/index.html WG-EMail: stds-802-1@ieee.org Contact: David Levi Postal: C/O IEEE 802.1 Working Group IEEE Standards Association 445 Hoes Lane P.O. Box 1331 Piscataway NJ 08855-1331 USA E-mail: STDS-802-1-L@LISTSERV.IEEE.ORG" DESCRIPTION "Provider Bridge MIB module. Unless otherwise indicated, the references in this MIB module are to IEEE 802.1Q-2011. Copyright (C) IEEE. This version of this MIB module is part of IEEE802.1Q; see the draft itself for full legal notices." REVISION "201202100000Z" -- February 10, 2012" DESCRIPTION "Deprecated ieee8021PbVidTranslationTable moved the new object to the Q Bridge as part of VID translation for 802.1aq." REVISION "201104060000Z" -- April 6, 2011 DESCRIPTION "Additions to support Remote Customer Service Interfaces." REVISION "201102270000Z" -- February 27, 2011 DESCRIPTION "Change to ieee8021PbEdgePortAcceptableFrameTypes permissible values, addition of IEEE8021BridgePortNumberOrZero to IMPORTS, as part of 2011 revision of IEEE Std 802.1Q." REVISION "201008260000Z" -- August 26, 2010 DESCRIPTION "Minor edits to contact information etc. as part of revision of Std 802.1Q." REVISION "200810150000Z" -- October 15, 2008 DESCRIPTION "Initial version." ::= { ieee802dot1mibs 5 } ieee8021PbNotifications OBJECT IDENTIFIER ::= { ieee8021PbMib 0 } ieee8021PbObjects OBJECT IDENTIFIER ::= { ieee8021PbMib 1 } ieee8021PbConformance OBJECT IDENTIFIER ::= { ieee8021PbMib 2 } -- =========================================================== -- ieee8021PbVidTranslationTable: -- Deprecated and moved VID translation to Q Bridge MIB. -- =========================================================== ieee8021PbVidTranslationTable OBJECT-TYPE SYNTAX SEQUENCE OF Ieee8021PbVidTranslationEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "This table is used to configure the VID Translation Table defined in 12.13.2 a) of 802.1Q-2006. The VID Translation Table is used to implement a bi-directional mapping between a local S-VID, used in data and protocol frames transmitted and received through a CNP or PNP, and a relay S-VID, used by the filtering and forwarding process. Each row in this table is indexed by component, port, and local S-VID value and indicates the relay S-VID value to be used for the specified S-VID. If no entry for a component, port, and local-svid is present in this table is present then the relay S-VID used for a frame received on that port with the local S-VID value will be the S-VID that has the same numeric value as the local S-VID of the received frame. Entries in this table must be persistent over power up restart/reboot." REFERENCE "12.13.2 a), 12.13.2.1, 12.13.2.2" ::= { ieee8021PbObjects 1 } ieee8021PbVidTranslationEntry OBJECT-TYPE SYNTAX Ieee8021PbVidTranslationEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "An entry for the S-VID translation table which includes both the Local and Relay S-VIDs between which the PNP or CNP translates. Note that the component ID of entries in this table must refer to the S-VLAN Component of a Provider Bridge." INDEX { ieee8021BridgeBasePortComponentId, ieee8021BridgeBasePort, ieee8021PbVidTranslationLocalVid } ::= { ieee8021PbVidTranslationTable 1 } Ieee8021PbVidTranslationEntry ::= SEQUENCE { ieee8021PbVidTranslationLocalVid VlanId, ieee8021PbVidTranslationRelayVid VlanId, ieee8021PbVidTranslationRowStatus RowStatus } ieee8021PbVidTranslationLocalVid OBJECT-TYPE SYNTAX VlanId MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "The S-VID on received(transmitted) at the ISS of a CNP or PNP." ::= { ieee8021PbVidTranslationEntry 1 } ieee8021PbVidTranslationRelayVid OBJECT-TYPE SYNTAX VlanId MAX-ACCESS read-create STATUS deprecated DESCRIPTION "The translated S-VID delivered(received) over the EISS from a CNP or PNP. The default value of this object on creation will be the value of the corresponding instance of ieee8021PbVidTranslationLocalVid." ::= { ieee8021PbVidTranslationEntry 2 } ieee8021PbVidTranslationRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS deprecated DESCRIPTION "This indicates the status of an entry in this table, and is used to create/delete entries. It is an implementation specific decision as to whether any column in this table may be set while the corresponding instance of this object is valid(1)." ::= { ieee8021PbVidTranslationEntry 3 } -- =========================================================== -- ieee8021PbCVidRegistrationTable: -- =========================================================== ieee8021PbCVidRegistrationTable OBJECT-TYPE SYNTAX SEQUENCE OF Ieee8021PbCVidRegistrationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table used in a CEP to create the mapping between a C-VID and a service represented by an S-VID. Note that the component ID of entries in this table must refer to the S-VLAN component of a Provider Edge Bridge and the Port Number must refer to the port number of the Customer Edge Port associated with that Provider Edge Bridge. Entries in this table must be persistent over power up restart/reboot." REFERENCE "12.13.3.1, 12.13.3.2" ::= { ieee8021PbObjects 2 } ieee8021PbCVidRegistrationEntry OBJECT-TYPE SYNTAX Ieee8021PbCVidRegistrationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An element of the C-VID registration table accessed by PB C-VLAN component, Customer Edge Port bridge port number, and C-VID. Each element contains the mapping between a C-VID and the S-VID which carries the service and booleans for handling untagged frames at the PEP and CEP." INDEX { ieee8021BridgeBasePortComponentId, ieee8021BridgeBasePort, ieee8021PbCVidRegistrationCVid } ::= { ieee8021PbCVidRegistrationTable 1 } Ieee8021PbCVidRegistrationEntry ::= SEQUENCE { ieee8021PbCVidRegistrationCVid VlanId, ieee8021PbCVidRegistrationSVid VlanId, ieee8021PbCVidRegistrationUntaggedPep TruthValue, ieee8021PbCVidRegistrationUntaggedCep TruthValue, ieee8021PbCVidRegistrationRowStatus RowStatus } ieee8021PbCVidRegistrationCVid OBJECT-TYPE SYNTAX VlanId MAX-ACCESS not-accessible STATUS current DESCRIPTION "C-VID of this C-VID registration entry." ::= { ieee8021PbCVidRegistrationEntry 1 } ieee8021PbCVidRegistrationSVid OBJECT-TYPE SYNTAX VlanId MAX-ACCESS read-create STATUS current DESCRIPTION "S-VID for this C-VID registration entry." ::= { ieee8021PbCVidRegistrationEntry 2 } ieee8021PbCVidRegistrationUntaggedPep OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "A flag indicating if this C-VID should be carried untagged at the PEP. A value of true(1) means untagged." DEFVAL { true } ::= { ieee8021PbCVidRegistrationEntry 3 } ieee8021PbCVidRegistrationUntaggedCep OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "A flag indicating if this C-VID should be carried untagged at the CEP. A value of true(1) means untagged." DEFVAL { true } ::= { ieee8021PbCVidRegistrationEntry 4 } ieee8021PbCVidRegistrationRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This indicates the status of an entry in this table, and is used to create/delete entries. The value of ieee8021PbCVidRegistrationSVid must be set before an entry in this table can be made valid. It is an implementation specific decision as to whether any column in this table may be set while the corresponding instance of this object is valid(1)." ::= { ieee8021PbCVidRegistrationEntry 5 } -- =========================================================== -- ieee8021PbEdgePortTable: -- =========================================================== ieee8021PbEdgePortTable OBJECT-TYPE SYNTAX SEQUENCE OF Ieee8021PbEdgePortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A Provider Edge Port (PEP) table which indicate the subset of parameters needed for each PEP." REFERENCE "12.13.3.3, 12.13.3.4" ::= { ieee8021PbObjects 3 } ieee8021PbEdgePortEntry OBJECT-TYPE SYNTAX Ieee8021PbEdgePortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the PEP table indexed by ComponentID and S-VID and containing parameters used to configure ingress filtering on the PEP, thus affecting traffic transiting from the provider network to the customer edge port. The columns allow the default C-VID value and default User Priority to be specified and PEP's ingress filtering operation to be controlled. Note that the component ID of entries in this table must refer to an S-VLAN component of a provider edge bridge and the Bridge Port number must refer to the port number of a Customer Edge Port associated with that Provider Edge Bridge." INDEX { ieee8021BridgeBasePortComponentId, ieee8021BridgeBasePort, ieee8021PbEdgePortSVid } ::= { ieee8021PbEdgePortTable 1 } Ieee8021PbEdgePortEntry ::= SEQUENCE { ieee8021PbEdgePortSVid VlanId, ieee8021PbEdgePortPVID VlanId, ieee8021PbEdgePortDefaultUserPriority IEEE8021PriorityValue, ieee8021PbEdgePortAcceptableFrameTypes IEEE8021PortAcceptableFrameTypes, ieee8021PbEdgePortEnableIngressFiltering TruthValue } ieee8021PbEdgePortSVid OBJECT-TYPE SYNTAX VlanId MAX-ACCESS not-accessible STATUS current DESCRIPTION "The 12 bit S-VID associated with the PEP." ::= { ieee8021PbEdgePortEntry 1 } ieee8021PbEdgePortPVID OBJECT-TYPE SYNTAX VlanId MAX-ACCESS read-write STATUS current DESCRIPTION "A 12-bit C-VID to be used for untagged frames received at the Provider Edge Port." ::= { ieee8021PbEdgePortEntry 2 } ieee8021PbEdgePortDefaultUserPriority OBJECT-TYPE SYNTAX IEEE8021PriorityValue MAX-ACCESS read-write STATUS current DESCRIPTION "An integer range 0-7 to be used for untagged frames received at the Provider Edge Port." ::= { ieee8021PbEdgePortEntry 3 } ieee8021PbEdgePortAcceptableFrameTypes OBJECT-TYPE SYNTAX IEEE8021PortAcceptableFrameTypes MAX-ACCESS read-write STATUS current DESCRIPTION "the Acceptable Frame Types for frames received at the PEP. The permissible values for the parameter are: 1) Admit all frames; 2) Admit only Untagged and Priority-Tagged frames; 3) Admit only VLAN-Tagged frames." DEFVAL { admitAll } ::= { ieee8021PbEdgePortEntry 4 } ieee8021PbEdgePortEnableIngressFiltering OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Filtering parameter for frames received at the PEP. The permissible values for the parameter are: true(1) Enabled; false(2) Disabled." DEFVAL { true } ::= { ieee8021PbEdgePortEntry 5 } -- =========================================================== -- ieee8021PbServicePriorityRegenerationTable: -- =========================================================== ieee8021PbServicePriorityRegenerationTable OBJECT-TYPE SYNTAX SEQUENCE OF Ieee8021PbServicePriorityRegenerationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The priority regeneration table for this PEP." REFERENCE "12.13.3.5, 12.13.3.6" ::= { ieee8021PbObjects 4 } ieee8021PbServicePriorityRegenerationEntry OBJECT-TYPE SYNTAX Ieee8021PbServicePriorityRegenerationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An element of the PEP priority regeneration table indexed by Component ID, bridge port number, S-VID, and received priority. Each element contains the regenerated priority. Note that the component ID of entries in this table must refer to the S-VLAN component of a Provider Edge Bridge and the Port Number must refer to the port number of the Customer Edge Port associated with that S-VLAN component." INDEX { ieee8021BridgeBasePortComponentId, ieee8021BridgeBasePort, ieee8021PbServicePriorityRegenerationSVid, ieee8021PbServicePriorityRegenerationReceivedPriority } ::= { ieee8021PbServicePriorityRegenerationTable 1 } Ieee8021PbServicePriorityRegenerationEntry ::= SEQUENCE { ieee8021PbServicePriorityRegenerationSVid VlanId, ieee8021PbServicePriorityRegenerationReceivedPriority IEEE8021PriorityValue, ieee8021PbServicePriorityRegenerationRegeneratedPriority IEEE8021PriorityValue } ieee8021PbServicePriorityRegenerationSVid OBJECT-TYPE SYNTAX VlanId MAX-ACCESS not-accessible STATUS current DESCRIPTION "S-VID for this regeneration table entry." ::= { ieee8021PbServicePriorityRegenerationEntry 1 } ieee8021PbServicePriorityRegenerationReceivedPriority OBJECT-TYPE SYNTAX IEEE8021PriorityValue MAX-ACCESS not-accessible STATUS current DESCRIPTION "Received priority for this regeneration table entry." ::= { ieee8021PbServicePriorityRegenerationEntry 2 } ieee8021PbServicePriorityRegenerationRegeneratedPriority OBJECT-TYPE SYNTAX IEEE8021PriorityValue MAX-ACCESS read-write STATUS current DESCRIPTION "The regenerated priority contained in this regeneration table entry." ::= { ieee8021PbServicePriorityRegenerationEntry 3 } -- =========================================================== -- ieee8021PbCnpTable -- =========================================================== ieee8021PbCnpTable OBJECT-TYPE SYNTAX SEQUENCE OF Ieee8021PbCnpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is used for dynamic creation and deletion of Customer Network Ports on S-VLAN components or I-components. Creation of an entry in this table will implicitly also create a corresponding entry in the ieee8021BridgeBasePortTable. Entries in this table must be persistent across reinitializations of the management system." REFERENCE "12.3.3" ::= { ieee8021PbObjects 5 } ieee8021PbCnpEntry OBJECT-TYPE SYNTAX Ieee8021PbCnpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Represents a dynamically created Customer Network Port." INDEX { ieee8021BridgeBasePortComponentId, ieee8021BridgeBasePort } ::= { ieee8021PbCnpTable 1 } Ieee8021PbCnpEntry ::= SEQUENCE { ieee8021PbCnpCComponentId IEEE8021PbbComponentIdentifierOrZero, ieee8021PbCnpSVid VlanIdOrNone, ieee8021PbCnpRowStatus RowStatus } ieee8021PbCnpCComponentId OBJECT-TYPE SYNTAX IEEE8021PbbComponentIdentifierOrZero MAX-ACCESS read-create STATUS current DESCRIPTION "The component ID of the C-Vlan component if this is an internal customer network port. The value must be 0 for an external customer network port. This value must be consistent with the value of the corresponding instance of ieee8021PbCnpSVid. Both must be non-zero, or both must be zero." ::= { ieee8021PbCnpEntry 1 } ieee8021PbCnpSVid OBJECT-TYPE SYNTAX VlanIdOrNone MAX-ACCESS read-create STATUS current DESCRIPTION "The S-VID for service for an internal customer network port. For an external port, this value must be 0. This value must be consistent with the value of the corresponding instance of ieee8021PbCnpCComponentId. Both must be non-zero, or both must be zero." ::= { ieee8021PbCnpEntry 2 } ieee8021PbCnpRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object is used for creation/deletion of entries in this table. All columns in this table must have valid values before this object can be set to active(1). While the value of this object is active(1), the values of other columns in the same entry may not be modified." ::= { ieee8021PbCnpEntry 3 } -- =========================================================== -- ieee8021PbPnpTable -- =========================================================== ieee8021PbPnpTable OBJECT-TYPE SYNTAX SEQUENCE OF Ieee8021PbPnpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is used for dynamic creation and deletion of Provider Network Ports on S-VLAN components or B-components. Creation of an entry in this table will implicitly also create a corresponding entry in the ieee8021BridgeBasePortTable. Entries in this table must be persistent across reinitializations of the management system." REFERENCE "12.13.3" ::= { ieee8021PbObjects 6 } ieee8021PbPnpEntry OBJECT-TYPE SYNTAX Ieee8021PbPnpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Represents a dynamically created Provider Network Port." INDEX { ieee8021BridgeBasePortComponentId, ieee8021BridgeBasePort } ::= { ieee8021PbPnpTable 1 } Ieee8021PbPnpEntry ::= SEQUENCE { ieee8021PbPnpRowStatus RowStatus } ieee8021PbPnpRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object is used for creation/deletion of entries in this table." ::= { ieee8021PbPnpEntry 1 } -- =========================================================== -- ieee8021PbCepTable -- =========================================================== ieee8021PbCepTable OBJECT-TYPE SYNTAX SEQUENCE OF Ieee8021PbCepEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is used to create Customer Edge Ports, CEPs, on a provider edge bridge. It is indexed by the ComponentId of the PEB's S-VLAN component and by the port number for the CEP. Note that the CEP's port number belongs to the set of port numbers associated with the PEB's S-VLAN component. Entries in this table must be persistent across reinitializations of the management system. However, note that some column values, as noted below, may change across system reinitializations." ::= { ieee8021PbObjects 7 } ieee8021PbCepEntry OBJECT-TYPE SYNTAX Ieee8021PbCepEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entry of the ieee8021PbCepTable. Note that the component index must refer to the S-VLAN component of a PEB, and that the port number for the CEP is allocated from the port number space of that S-VLAN component." INDEX { ieee8021BridgeBasePortComponentId, ieee8021BridgeBasePort } ::= { ieee8021PbCepTable 1 } Ieee8021PbCepEntry ::= SEQUENCE { ieee8021PbCepCComponentId IEEE8021PbbComponentIdentifierOrZero, ieee8021PbCepCepPortNumber IEEE8021BridgePortNumberOrZero, ieee8021PbCepRowStatus RowStatus } ieee8021PbCepCComponentId OBJECT-TYPE SYNTAX IEEE8021PbbComponentIdentifierOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "This column is an implmentation specific column that may be used to map the C component associated with this CEP to other tables within the system, such as the Entity MIB. This column may not be created or modified by management station action. A value of 0 is always legal, and non-zero values will be interpreted in an implementation specific manner. The value of this column may or may not persist across system restarts." ::= { ieee8021PbCepEntry 1 } ieee8021PbCepCepPortNumber OBJECT-TYPE SYNTAX IEEE8021BridgePortNumberOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "This column is an implementation specific column that may be used to map the CEP to other tables within the system, for example the Entity MIB. This column may not be created or modified by management station action. A value of 0 is always legal, and non-zero values will be interpreted in an implementation specific manner. The value of this column may or may not persist across system restarts." ::= { ieee8021PbCepEntry 2 } ieee8021PbCepRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This indicates the status of the entry, and is used to create and delete entries in this table." ::= { ieee8021PbCepEntry 3 } -- =========================================================== -- ieee8021PbRcapTable -- =========================================================== ieee8021PbRcapTable OBJECT-TYPE SYNTAX SEQUENCE OF Ieee8021PbRcapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is used to create Remote Customer Access Ports, on a provider edge bridge. It is indexed by the ComponentId of the PEB's S-VLAN component and by the port number for the RCAP. Note that the index port number belongs to the set of port numbers associated with the PEB's primary S-VLAN component. Entries in this table must be persistent across reinitializations of the management agent. However, note that some column values, as noted below, may change across system reinitializations." ::= { ieee8021PbObjects 8 } ieee8021PbRcapEntry OBJECT-TYPE SYNTAX Ieee8021PbRcapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entry of the ieee8021PbRcapTable. Note that the component index must refer to the primary S-VLAN component of a PEB, and that the port number index for the RCAP is allocated from the port number space of that S-VLAN component." INDEX { ieee8021BridgeBasePortComponentId, ieee8021BridgeBasePort } ::= { ieee8021PbRcapTable 1 } Ieee8021PbRcapEntry ::= SEQUENCE { ieee8021PbRcapSComponentId IEEE8021PbbComponentIdentifierOrZero, ieee8021PbRcapRcapPortNumber IEEE8021BridgePortNumberOrZero, ieee8021PbRcapRowStatus RowStatus } ieee8021PbRcapSComponentId OBJECT-TYPE SYNTAX IEEE8021PbbComponentIdentifierOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "This column is an implmentation specific column that may be used to map the Port-mapping S-VLAN component associated with this RCAP to other tables within the system, such as the Entity MIB. This column may not be created or modified by management station action. A value of 0 is always legal, and non-zero values will be interpreted in an implementation specific manner. The value of this column may or may not persist across system restarts." ::= { ieee8021PbRcapEntry 1 } ieee8021PbRcapRcapPortNumber OBJECT-TYPE SYNTAX IEEE8021BridgePortNumberOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "This column is an implementation specific column that may be used to map the RCAP to other tables within the system, for example the Entity MIB. This column may not be created or modified by management station action. A value of 0 is always legal, and non-zero values will be interpreted in an implementation specific manner. The value of this column may or may not persist across system restarts." ::= { ieee8021PbRcapEntry 2 } ieee8021PbRcapRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This indicates the status of the entry, and is used to create and delete entries in this table." ::= { ieee8021PbRcapEntry 3 } -- =========================================================== -- ieee8021PbInternalInterfaceTable: -- =========================================================== ieee8021PbInternalInterfaceTable OBJECT-TYPE SYNTAX SEQUENCE OF Ieee8021PbIiEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table used in a Port-mapping S-VLAN component associated with a Remote Customer Access Port to manage the mapping between external S-VIDs and internal interfaces/S-VIDs. Note that the component ID of entries in this table must refer to the primary S-VLAN component of a Provider Edge Bridge and the Port Number must refer to the port number of a Remote Customer Access Port associated with that S-VLAN component. Entries in this table must be persistent over power up restart/reboot." REFERENCE "12.13.4.1, 12.13.4.2" ::= { ieee8021PbObjects 9 } ieee8021PbIiEntry OBJECT-TYPE SYNTAX Ieee8021PbIiEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An element of the internal interface table accessed by PB S-VLAN component ID, Remnote Customer Access Port bridge port number, and external S-VID. Each element contains the mapping between an external S-VID and the internal port it selects and, except in the case of a C-tagged service interface the internal S-VID which carries the service ." INDEX { ieee8021BridgeBasePortComponentId, ieee8021BridgeBasePort, ieee8021PbIiExternalSVid } ::= { ieee8021PbInternalInterfaceTable 1 } Ieee8021PbIiEntry ::= SEQUENCE { ieee8021PbIiExternalSVid VlanId, ieee8021PbIiInternalPortNumber IEEE8021BridgePortNumberOrZero, ieee8021PbIiInternalPortType IEEE8021BridgePortType, ieee8021PbIiInternalSVid VlanIdOrNone, ieee8021PbIiRowStatus RowStatus } ieee8021PbIiExternalSVid OBJECT-TYPE SYNTAX VlanId MAX-ACCESS not-accessible STATUS current DESCRIPTION "External S-VID for this internal interface table entry." ::= { ieee8021PbIiEntry 1 } ieee8021PbIiInternalPortNumber OBJECT-TYPE SYNTAX IEEE8021BridgePortNumberOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "The port number for the internal port on the primary S-VLAN component. This port number is used in FDB entries that reference an RCSI. The port number of the Remote Customer Access Port can be used to identify a PNP on the primary S-VLAN component connected to a PNP on the Port-mapping S-VLAN component." ::= { ieee8021PbIiEntry 2 } ieee8021PbIiInternalPortType OBJECT-TYPE SYNTAX IEEE8021BridgePortType MAX-ACCESS read-create STATUS current DESCRIPTION "The port type of the internal port on the primary S-VLAN component. This indicates the type of RCSI as follows: providerNetworkPort(3) - Indicates a PNP (not an RCSI) customerNetworkPort(4) - Indicates a Port-based RCSI customerEdgePort(5) - Indicates a C-tagged RCSI Other port type values are not valid for this field." ::= { ieee8021PbIiEntry 3 } ieee8021PbIiInternalSVid OBJECT-TYPE SYNTAX VlanIdOrNone MAX-ACCESS read-create STATUS current DESCRIPTION "Internal S-VID for this external S-VID entry." ::= { ieee8021PbIiEntry 4 } ieee8021PbIiRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This indicates the status of an entry in this table, and is used to create/delete entries. The value of ieee8021PbIiExternalSVid must be set before an entry in this table can be made valid.deprecated It is an implementation specific decision as to whether any column in this table may be set while the corresponding instance of this object is valid(1)." ::= { ieee8021PbIiEntry 5 } -- ============================================================= -- Conformance Information -- ============================================================= ieee8021PbGroups OBJECT IDENTIFIER ::= { ieee8021PbConformance 1 } ieee8021PbCompliances OBJECT IDENTIFIER ::= { ieee8021PbConformance 2 } -- ============================================================= -- Units of conformance -- ============================================================= ieee8021PbVidTranslationGroup OBJECT-GROUP OBJECTS { ieee8021PbVidTranslationRelayVid, ieee8021PbVidTranslationRowStatus } STATUS deprecated DESCRIPTION "The collection of objects used to represent a PB C-VID/S-VID translation." ::= { ieee8021PbGroups 1 } ieee8021PbCVidRegistrationGroup OBJECT-GROUP OBJECTS { ieee8021PbCVidRegistrationSVid, ieee8021PbCVidRegistrationUntaggedPep, ieee8021PbCVidRegistrationUntaggedCep, ieee8021PbCVidRegistrationRowStatus } STATUS current DESCRIPTION "The collection of objects used to represent a CEP translation." ::= { ieee8021PbGroups 2 } ieee8021PbEdgePortGroup OBJECT-GROUP OBJECTS { ieee8021PbEdgePortPVID, ieee8021PbEdgePortDefaultUserPriority, ieee8021PbEdgePortAcceptableFrameTypes, ieee8021PbEdgePortEnableIngressFiltering } STATUS current DESCRIPTION "The collection of objects user to represent a PEP." ::= { ieee8021PbGroups 3 } ieee8021PbServicePriorityRegenerationGroup OBJECT-GROUP OBJECTS { ieee8021PbServicePriorityRegenerationRegeneratedPriority } STATUS current DESCRIPTION "A regenerated priority value for a PEP." ::= { ieee8021PbGroups 4 } ieee8021PbDynamicCnpGroup OBJECT-GROUP OBJECTS { ieee8021PbCnpCComponentId, ieee8021PbCnpSVid, ieee8021PbCnpRowStatus } STATUS current DESCRIPTION "A set of objects used for dynamic creation and deletion of customer network ports." ::= { ieee8021PbGroups 5 } ieee8021PbDynamicPnpGroup OBJECT-GROUP OBJECTS { ieee8021PbPnpRowStatus } STATUS current DESCRIPTION "A set of objects used for dynamic creation and deletion of provider network ports." ::= { ieee8021PbGroups 6 } ieee8021PbDynamicCepGroup OBJECT-GROUP OBJECTS { ieee8021PbCepCComponentId, ieee8021PbCepCepPortNumber, ieee8021PbCepRowStatus } STATUS current DESCRIPTION "A set of objects used for dynamic creation and deletion of customer edge ports." ::= { ieee8021PbGroups 7 } ieee8021PbDynamicRcapGroup OBJECT-GROUP OBJECTS { ieee8021PbRcapSComponentId, ieee8021PbRcapRcapPortNumber, ieee8021PbCepRowStatus } STATUS current DESCRIPTION "A set of objects used for dynamic creation and deletion of remote customer access ports." ::= { ieee8021PbGroups 8 } ieee8021PbInternalInterfaceGroup OBJECT-GROUP OBJECTS { ieee8021PbIiInternalPortNumber, ieee8021PbIiInternalPortType, ieee8021PbIiInternalSVid, ieee8021PbIiRowStatus } STATUS current DESCRIPTION "A set of objects used for dynamic creation and deletion of internal interfaces on a Port-mapping S-VLAN component." ::= { ieee8021PbGroups 9 } -- ============================================================= -- Compliance statements -- ============================================================= ieee8021PbCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for device support of Provider Bridge services." MODULE MANDATORY-GROUPS { ieee8021PbVidTranslationGroup, ieee8021PbCVidRegistrationGroup, ieee8021PbEdgePortGroup, ieee8021PbServicePriorityRegenerationGroup } GROUP ieee8021PbDynamicCnpGroup DESCRIPTION "This group is optional and supports dynamic creation and deletion of customer network ports." GROUP ieee8021PbDynamicPnpGroup DESCRIPTION "This group is optional and supports dynamic creation and deletion of provider network ports." GROUP ieee8021PbDynamicCepGroup DESCRIPTION "This group is optional and supports dynamic creation and deletion of customer edge ports." GROUP ieee8021PbDynamicRcapGroup DESCRIPTION "This group is optional and supports dynamic creation and deletion of remote customer access ports." GROUP ieee8021PbInternalInterfaceGroup DESCRIPTION "This group is optional and supports dynamic creation and deletion of internal interfaces on Port-mapping S-VLAN components." ::= { ieee8021PbCompliances 1 } END