IEEE8021-PSFP-MIB DEFINITIONS ::= BEGIN -- ============================================================= -- MIB for support of the Per-Stream Filtering and Policing -- Enhancements for 802.1Q Bridges. -- ============================================================= IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Unsigned32, Integer32, Counter64 FROM SNMPv2-SMI TruthValue, RowStatus FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF ieee802dot1mibs FROM IEEE8021-TC-MIB ieee8021BridgeBaseComponentId FROM IEEE8021-BRIDGE-MIB IEEE8021STPTPtimeValue FROM IEEE8021-ST-MIB ; ieee8021PSFPMib MODULE-IDENTITY LAST-UPDATED "201709080000Z" -- October 6, 2017 ORGANIZATION "IEEE 802.1 Working Group" CONTACT-INFO " WG-URL: http://www.ieee802.org/1/ WG-EMail: stds-802-1-L@ieee.org Contact: IEEE 802.1 Working Group Chair Postal: C/O IEEE 802.1 Working Group IEEE Standards Association 445 Hoes Lane P.O. Box 1331 Piscataway NJ 08855-1331 USA E-mail: stds-802-1-L@ieee.org" DESCRIPTION "The Bridge MIB module for managing devices that support the Per-Stream Filtering and Policing enhancements for 802.1Q Bridges. Unless otherwise indicated, the references in this MIB module are to IEEE Std 802.1Q-2014. Copyright (C) IEEE (2017). This version of this MIB module is part of IEEE802.1Q; see the draft itself for full legal notices." REVISION "201709080000Z" -- October 6, 2017 DESCRIPTION "Initial version published as part of IEEE Std 802.1Qci." ::= { ieee802dot1mibs 31 } -- ============================================================= -- subtrees in the PSFP MIB -- ============================================================= ieee8021PSFPNotifications OBJECT IDENTIFIER ::= { ieee8021PSFPMib 0 } ieee8021PSFPObjects OBJECT IDENTIFIER ::= { ieee8021PSFPMib 1 } ieee8021PSFPConformance OBJECT IDENTIFIER ::= { ieee8021PSFPMib 2 } ieee8021PSFPStreamFilterParameters OBJECT IDENTIFIER ::= { ieee8021PSFPObjects 1 } ieee8021PSFPStreamGateParameters OBJECT IDENTIFIER ::= { ieee8021PSFPObjects 2 } ieee8021PSFPFlowMeterParameters OBJECT IDENTIFIER ::= { ieee8021PSFPObjects 3 } ieee8021PSFPStreamParameters OBJECT IDENTIFIER ::= { ieee8021PSFPObjects 4 } -- ============================================================= -- The ieee8021PSFPStreamFilterParameters subtree -- This subtree defines the objects necessary for the management -- of the stream filters for IEEE Std 802.1Q. -- ============================================================= -- ============================================================= -- the ieee8021PSFPStreamFilterTable -- ============================================================= ieee8021PSFPStreamFilterTable OBJECT-TYPE SYNTAX SEQUENCE OF Ieee8021PSFPStreamFilterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains the per-filter instance manageable parameters for stream filters. A row in the table exists for each stream filter instance. associated with a Bridge component. All writable objects in this table must be persistent over power up restart/reboot." REFERENCE "8.6.5, 8.6.5.1 12.31.2" ::= { ieee8021PSFPStreamFilterParameters 1 } ieee8021PSFPStreamFilterEntry OBJECT-TYPE SYNTAX Ieee8021PSFPStreamFilterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of objects that contains the manageable parameters for stream filters for a Bridge component." INDEX { ieee8021BridgeBaseComponentId, ieee8021PSFPStreamFilterInstance } ::= { ieee8021PSFPStreamFilterTable 1 } Ieee8021PSFPStreamFilterEntry ::= SEQUENCE { ieee8021PSFPStreamFilterInstance Unsigned32, ieee8021PSFPStreamHandleSpec Integer32, ieee8021PSFPPrioritySpec Integer32, ieee8021PSFPStreamGateInstanceID Unsigned32, ieee8021PSFPFilterSpecificationList OCTET STRING, ieee8021PSFPMatchingFramesCount Counter64, ieee8021PSFPPassingFramesCount Counter64, ieee8021PSFPNotPassingFramesCount Counter64, ieee8021PSFPPassingSDUCount Counter64, ieee8021PSFPNotPassingSDUCount Counter64, ieee8021PSFPREDFramesCount Counter64, ieee8021PSFPStreamBlockedDueToOversizeFrameEnable TruthValue, ieee8021PSFPStreamBlockedDueToOversizeFrame TruthValue, ieee8021PSFPStreamFilterEntryRowStatus RowStatus } ieee8021PSFPStreamFilterInstance OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The StreamFilterInstance parameter is an index into the StreamFilterTable. The value of this object MUST be retained across reinitializations of the management system." REFERENCE "8.6.5.1, 12.31.2" ::= { ieee8021PSFPStreamFilterEntry 1} ieee8021PSFPStreamHandleSpec OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-create STATUS current DESCRIPTION "The StreamHandleSpec parameter contains a stream identifier specification value. A value of -1 denotes the wild card value; all positive values denote stream identifier values. The value of this object MUST be retained across reinitializations of the management system." REFERENCE "8.6.5.1, 12.31.2" ::= { ieee8021PSFPStreamFilterEntry 2} ieee8021PSFPPrioritySpec OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-create STATUS current DESCRIPTION "The PrioritySpec parameter contains a priority specification value. A value of -1 denotes the wild card value; zero or positive values denote priority values. The value of this object MUST be retained across reinitializations of the management system." REFERENCE "8.6.5.1, 12.31.2" ::= { ieee8021PSFPStreamFilterEntry 3} ieee8021PSFPStreamGateInstanceID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "The StreamGateInstance parameter contains the index of an entry in the Stream Gate Table. The value of this object MUST be retained across reinitializations of the management system." REFERENCE "8.6.5.1, 12.31.2" ::= { ieee8021PSFPStreamFilterEntry 4} ieee8021PSFPFilterSpecificationList OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "The FilterSpecificationList parameter contains a list of filter specifications associated with this stream filter. The octet string value represents the contents of the list as an ordered list of entries, each encoded as a TLV, as follows. The first octet of each TLV is interpreted as an unsigned integer representing a filter specification type: 0: Maximum SDU Size. 1: Flow meter instance identifier. 2-255: Reserved for future gate operations The second and third octets of the TLV are the length field, interpreted as an unsigned integer, indicating the number of octets of the value that follows the length. A length of zero indicates that there is no value (i.e., the filter specification has no parameters). The fourth through (4 + length -1)th octets encode the parameters of the filter specification, as defined for each filter specification type. - Maximum SDU Size: A single SDU size parameter is encoded in four octets, and is interpreted as an unsigned integer value. - Flow meter instance identifier: A single flow meter instance identifier is encoded in four octets, and is interpreted as an unsigned integer value. The value of this object MUST be retained across reinitializations of the management system." REFERENCE "8.6.5.1, 12.31.2" ::= { ieee8021PSFPStreamFilterEntry 5} ieee8021PSFPMatchingFramesCount OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The MatchingFramesCount counter counts received frames that match this stream filter. " REFERENCE "8.6.5.1, 12.31.2" ::= { ieee8021PSFPStreamFilterEntry 6} ieee8021PSFPPassingFramesCount OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The PassingFramesCount counter counts received frames that pass the gate associated with this stream filter. " REFERENCE "8.6.5.1, 12.31.2" ::= { ieee8021PSFPStreamFilterEntry 7} ieee8021PSFPNotPassingFramesCount OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The NotPassingFramesCount counter counts received frames that do not pass the gate associated with this stream filter. " REFERENCE "8.6.5.1, 12.31.2" ::= { ieee8021PSFPStreamFilterEntry 8} ieee8021PSFPPassingSDUCount OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The PassingSDUCount counter counts received frames that pass the SDU size filter specification associated with this stream filter. " REFERENCE "8.6.5.1, 12.31.2" ::= { ieee8021PSFPStreamFilterEntry 9} ieee8021PSFPNotPassingSDUCount OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The NotPassingSDUCount counter counts received frames that do not pass the SDU size filter specification associated with this stream filter. " REFERENCE "8.6.5.1, 12.31.2" ::= { ieee8021PSFPStreamFilterEntry 10} ieee8021PSFPREDFramesCount OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The REDFramesCount counter counts received random early detection (RED) frames associated with this stream filter. " REFERENCE "8.6.5.1, 12.31.2" ::= { ieee8021PSFPStreamFilterEntry 11} ieee8021PSFPStreamBlockedDueToOversizeFrameEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "The ieee8021PSFPStreamBlockedDueToOversizeFrameEnable object contains a Boolean value that indicates whether the ieee8021PSFPStreamBlockedDueToOversizeFrame function is enabled (TRUE) or disabled (FALSE). The value of this object MUST be retained across reinitializations of the management system." REFERENCE "8.6.5.1, 8.6.5.1.1, 12.31.2" DEFVAL { false } ::= { ieee8021PSFPStreamFilterEntry 12 } ieee8021PSFPStreamBlockedDueToOversizeFrame OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "The ieee8021PSFPStreamBlockedDueToOversizeFrame object contains a Boolean value that indicates whether, if the ieee8021PSFPStreamBlockedDueToOversizeFrame function is enabled, all frames are to be discarded (TRUE) or not (FALSE). The value of this object MUST be retained across reinitializations of the management system." REFERENCE "8.6.5.1, 8.6.5.1.1, 12.31.2" DEFVAL { false } ::= { ieee8021PSFPStreamFilterEntry 13 } ieee8021PSFPStreamFilterEntryRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of the row. The writable columns in a row can not be changed if the row is active. All columns MUST have a valid value before a row can be activated. " ::= { ieee8021PSFPStreamFilterEntry 14 } -- ============================================================= -- The ieee8021PSFPStreamGateParameters subtree -- This subtree defines the objects necessary for the management -- of the stream gate scheduling mechanism for IEEE Std 802.1Q. -- ============================================================= -- ============================================================= -- the ieee8021PSFPStreamGateTable -- ============================================================= ieee8021PSFPStreamGateTable OBJECT-TYPE SYNTAX SEQUENCE OF Ieee8021PSFPStreamGateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains the per-gate instance manageable parameters for stream gate scheduling. For a given Bridge component, a row in the table exists for each stream gate instance. All writable objects in this table must be persistent over power up restart/reboot." REFERENCE "8.6.8.4, 8.6.9.4, 12.31.3" ::= { ieee8021PSFPStreamGateParameters 1 } ieee8021PSFPStreamGateEntry OBJECT-TYPE SYNTAX Ieee8021PSFPStreamGateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of objects that contains the manageable parameters for stream gate scheduling for a Bridge component." INDEX { ieee8021BridgeBaseComponentId, ieee8021PSFPStreamGateInstance } ::= { ieee8021PSFPStreamGateTable 1 } Ieee8021PSFPStreamGateEntry ::= SEQUENCE { ieee8021PSFPStreamGateInstance Unsigned32, ieee8021PSFPGateEnabled TruthValue, ieee8021PSFPAdminGateStates INTEGER, ieee8021PSFPOperGateStates INTEGER, ieee8021PSFPAdminControlListLength Unsigned32, ieee8021PSFPOperControlListLength Unsigned32, ieee8021PSFPAdminControlList OCTET STRING, ieee8021PSFPOperControlList OCTET STRING, ieee8021PSFPAdminCycleTimeNumerator Unsigned32, ieee8021PSFPAdminCycleTimeDenominator Unsigned32, ieee8021PSFPOperCycleTimeNumerator Unsigned32, ieee8021PSFPOperCycleTimeDenominator Unsigned32, ieee8021PSFPAdminCycleTimeExtension Unsigned32, ieee8021PSFPOperCycleTimeExtension Unsigned32, ieee8021PSFPAdminBaseTime IEEE8021STPTPtimeValue, ieee8021PSFPOperBaseTime IEEE8021STPTPtimeValue, ieee8021PSFPConfigChange TruthValue, ieee8021PSFPConfigChangeTime IEEE8021STPTPtimeValue, ieee8021PSFPTickGranularity Unsigned32, ieee8021PSFPCurrentTime IEEE8021STPTPtimeValue, ieee8021PSFPConfigPending TruthValue, ieee8021PSFPConfigChangeError Counter64, ieee8021PSFPAdminIPV Integer32, ieee8021PSFPOperIPV Integer32, ieee8021PSFPGateClosedDueToInvalidRxEnable TruthValue, ieee8021PSFPGateClosedDueToInvalidRx TruthValue, ieee8021PSFPGateClosedDueToOctetsExceededEnable TruthValue, ieee8021PSFPGateClosedDueToOctetsExceeded TruthValue, ieee8021PSFPStreamGateEntryRowStatus RowStatus } ieee8021PSFPStreamGateInstance OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The StreamGateInstance parameter is an index into the StreamGateTable. The value of this object MUST be retained across reinitializations of the management system." REFERENCE "8.6.5.1, 8.6.5.1.2, 12.31.3" ::= { ieee8021PSFPStreamGateEntry 1} ieee8021PSFPGateEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "The GateEnabled parameter determines whether the stream gate is active (true) or inactive (false). The value of this object MUST be retained across reinitializations of the management system." REFERENCE "8.6.8.4, 8.6.9.4, 12.31.3" DEFVAL { false } ::= { ieee8021PSFPStreamGateEntry 2} ieee8021PSFPAdminGateStates OBJECT-TYPE SYNTAX INTEGER { open(1), closed(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "The administrative value of the GateStates parameter for the stream gate. The open value indicates that the gate is open, the closed value indicates that the gate is closed. The value of this object MUST be retained across reinitializations of the management system." REFERENCE "8.6.8.4, 8.6.9.4, 12.31.3" ::= { ieee8021PSFPStreamGateEntry 3 } ieee8021PSFPOperGateStates OBJECT-TYPE SYNTAX INTEGER { open(1), closed(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The operational value of the GateStates parameter for the stream gate. The open value indicates that the gate is open, the closed value indicates that the gate is closed. " REFERENCE "8.6.8.4, 8.6.9.4, 12.31.3" ::= { ieee8021PSFPStreamGateEntry 4 } ieee8021PSFPAdminControlListLength OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "The administrative value of the ListMax parameter for the gate. The integer value indicates the number of entries (TLVs) in the AdminControlList. The value of this object MUST be retained across reinitializations of the management system." REFERENCE "8.6.8.4, 8.6.9.4, 12.31.3" ::= { ieee8021PSFPStreamGateEntry 5 } ieee8021PSFPOperControlListLength OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The operational value of the ListMax parameter for the gate. The integer value indicates the number of entries (TLVs) in the OperControlList." REFERENCE "8.6.8.4, 8.6.9.4, 12.31.3" ::= { ieee8021PSFPStreamGateEntry 6 } ieee8021PSFPAdminControlList OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "The administrative value of the ControlList parameter for the gate. The octet string value represents the contents of the control list as an ordered list of entries, each encoded as a TLV, as follows. The first octet of each TLV is interpreted as an unsigned integer representing a gate operation name: 0: SetGateAndIPV 1-255: Reserved for future gate operations The second octet of the TLV is the length field, interpreted as an unsigned integer, indicating the number of octets of the value that follows the length. A length of zero indicates that there is no value (i.e., the gate operation has no parameters). The third through (3 + length -1)th octets encode the parameters of the gate operation, in the order that they appear in the definition of the operation in Table 8-7. Three parameter types are defined: - StreamGateState: A GateState parameter is encoded in a single octet, and is interpreted as an integer value. The value 1 indicates open; the value 2 indicates closed. - IPV: An IPV is encoded in four octets as a 32-bit signed integer. A negative denotes the null value; zero or positive values denote internal priority values. - TimeInterval: A TimeInterval is encoded in 4 octets as a 32-bit unsigned integer, representing a number of nanoseconds. The first octet encodes the most significant 8 bits of the integer, and the fourth octet encodes the least significant 8 bits. - IntervalOctetMax: An integer representing the maximum number of MSDU octets that are permitted to pas the gate during the specified TimeInterval. If this parameter is omitted, there is no maximum. The value of this object MUST be retained across reinitializations of the management system." REFERENCE "8.6.8.4, 8.6.9.4, 12.31.3" ::= { ieee8021PSFPStreamGateEntry 7 } ieee8021PSFPOperControlList OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The operational value of the ControlList parameter for the gate. The octet string value represents the contents of the control list as an ordered list of entries, each encoded as a TLV, as follows. The first octet of each TLV is interpreted as an unsigned integer representing a gate operation name: 0: SetGateAndIPV 1-255: Reserved for future gate operations The second octet of the TLV is the length field, interpreted as an unsigned integer, indicating the number of octets of the value that follows the length. A length of zero indicates that there is no value (i.e., the gate operation has no parameters). The third through (3 + length -1)th octets encode the parameters of the gate operation, in the order that they appear in the definition of the operation in Table 8-7. Three parameter types are defined: - StreamGateState: A GateState parameter is encoded in a single octet, and is interpreted as an integer value. The value 1 indicates open; the value 2 indicates closed. - IPV: An IPV is encoded in four octets as a 32-bit signed integer. A negative value denotes the null value; zero and positive values denote internal priority values. - TimeInterval: A TimeInterval is encoded in 4 octets as a 32-bit unsigned integer, representing a number of nanoseconds. The first octet encodes the most significant 8 bits of the integer, and the fourth octet encodes the least significant 8 bits. - IntervalOctetMax: An integer representing the maximum number of MSDU octets that are permitted to pas the gate during the specified TimeInterval. If this parameter is omitted, there is no maximum. " REFERENCE "8.6.8.4, 8.6.9.4, 12.31.3" ::= { ieee8021PSFPStreamGateEntry 8 } ieee8021PSFPAdminCycleTimeNumerator OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "The administrative value of the numerator of the CycleTime parameter for the gate. The numerator and denominator together represent the cycle time as a rational number of seconds. The value of this object MUST be retained across reinitializations of the management system." REFERENCE "8.6.8.4, 8.6.9.4, 12.31.3" ::= { ieee8021PSFPStreamGateEntry 9 } ieee8021PSFPAdminCycleTimeDenominator OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "The administrative value of the denominator of the CycleTime parameter for the gate. The numerator and denominator together represent the cycle time as a rational number of seconds. The value of this object MUST be retained across reinitializations of the management system." REFERENCE "8.6.8.4, 8.6.9.4, 12.31.3" ::= { ieee8021PSFPStreamGateEntry 10 } ieee8021PSFPOperCycleTimeNumerator OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The operational value of the numerator of the CycleTime parameter for the gate. The numerator and denominator together represent the cycle time as a rational number of seconds." REFERENCE "8.6.8.4, 8.6.9.4, 12.31.3" ::= { ieee8021PSFPStreamGateEntry 11 } ieee8021PSFPOperCycleTimeDenominator OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The operational value of the denominator of the CycleTime parameter for the gate. The numerator and denominator together represent the cycle time as a rational number of seconds." REFERENCE "8.6.8.4, 8.6.9.4, 12.31.3" ::= { ieee8021PSFPStreamGateEntry 12 } ieee8021PSFPAdminCycleTimeExtension OBJECT-TYPE SYNTAX Unsigned32 UNITS "nanoseconds" MAX-ACCESS read-create STATUS current DESCRIPTION "The administrative value of the CycleTimeExtension parameter for the gate. The value is an unsigned integer number of nanoseconds. The value of this object MUST be retained across reinitializations of the management system." REFERENCE "8.6.8.4, 8.6.9.4, 12.31.3" ::= { ieee8021PSFPStreamGateEntry 13 } ieee8021PSFPOperCycleTimeExtension OBJECT-TYPE SYNTAX Unsigned32 UNITS "nanoseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The operational value of the CycleTimeExtension parameter for the gate. The value is an unsigned integer number of nanoseconds." REFERENCE "8.6.8.4, 8.6.9.4, 12.31.3" ::= { ieee8021PSFPStreamGateEntry 14 } ieee8021PSFPAdminBaseTime OBJECT-TYPE SYNTAX IEEE8021STPTPtimeValue UNITS "PTP time" MAX-ACCESS read-create STATUS current DESCRIPTION "The administrative value of the BaseTime parameter for the gate. The value is a representation of a PTPtime value, consisting of a 48-bit integer number of seconds and a 32-bit integer number of nanoseconds. The value of this object MUST be retained across reinitializations of the management system." REFERENCE "8.6.8.4, 8.6.9.4, 12.31.3" ::= { ieee8021PSFPStreamGateEntry 15 } ieee8021PSFPOperBaseTime OBJECT-TYPE SYNTAX IEEE8021STPTPtimeValue UNITS "PTP time" MAX-ACCESS read-only STATUS current DESCRIPTION "The operationsl value of the BaseTime parameter for the gate. The value is a representation of a PTPtime value, consisting of a 48-bit integer number of seconds and a 32-bit integer number of nanoseconds." REFERENCE "8.6.8.4, 8.6.9.4, 12.31.3" ::= { ieee8021PSFPStreamGateEntry 16 } ieee8021PSFPConfigChange OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "The ConfigChange parameter signals the start of a configuration change for the gate when it is set to TRUE. This should only be done when the various administrative parameters are all set to appropriate values." REFERENCE "8.6.8.4, 8.6.9.4, 12.31.3" ::= { ieee8021PSFPStreamGateEntry 17 } ieee8021PSFPConfigChangeTime OBJECT-TYPE SYNTAX IEEE8021STPTPtimeValue UNITS "PTP time" MAX-ACCESS read-only STATUS current DESCRIPTION "The PTPtime at which the next config change is scheduled to occur. The value is a representation of a PTPtime value, consisting of a 48-bit integer number of seconds and a 32-bit integer number of nanoseconds. The value of this object MUST be retained across reinitializations of the management system." REFERENCE "8.6.8.4, 8.6.9.4, 12.31.3" ::= { ieee8021PSFPStreamGateEntry 18 } ieee8021PSFPTickGranularity OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The granularity of the cycle time clock, represented as an unsigned number of tenths of nanoseconds. The value of this object MUST be retained across reinitializations of the management system." REFERENCE "8.6.8.4, 8.6.9.4, 12.31.3" ::= { ieee8021PSFPStreamGateEntry 19 } ieee8021PSFPCurrentTime OBJECT-TYPE SYNTAX IEEE8021STPTPtimeValue MAX-ACCESS read-only STATUS current DESCRIPTION "The current time, in PTPtime, as maintained by the local system. The value is a representation of a PTPtime value, consisting of a 48-bit integer number of seconds and a 32-bit integer number of nanoseconds." REFERENCE "8.6.8.4, 8.6.9.4, 12.31.3" ::= { ieee8021PSFPStreamGateEntry 20 } ieee8021PSFPConfigPending OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the ConfigPending state machine variable. The value is TRUE if a configuration change is in progress but has not yet completed." REFERENCE "8.6.8.4, 8.6.9.4, 12.31.3" ::= { ieee8021PSFPStreamGateEntry 21 } ieee8021PSFPConfigChangeError OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "A counter of the number of times that a re-configuration of the traffic schedule has been requested with the old schedule still running and the requested base time was in the past." REFERENCE "8.6.8.4, 8.6.9.3, 8.6.9.1.1, 12.31.3" ::= { ieee8021PSFPStreamGateEntry 23 } ieee8021PSFPAdminIPV OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-create STATUS current DESCRIPTION "The administrative value of the IPV parameter for the gate. A value of -1 denotes the null value. " REFERENCE "8.6.5.1.2, 8.6.10, 12.31.3" ::= { ieee8021PSFPStreamGateEntry 24 } ieee8021PSFPOperIPV OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-create STATUS current DESCRIPTION "The operational value of the IPV parameter for the gate. A value of -1 denotes the null value. " REFERENCE "8.6.5.1.2, 8.6.10, 12.31.3" ::= { ieee8021PSFPStreamGateEntry 25 } ieee8021PSFPGateClosedDueToInvalidRxEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "The PSFPGateClosedDueToInvalidRxEnable object contains a Boolean value that indicates whether the PSFPGateClosedDueToInvalidRx function is enabled (TRUE) or disabled (FALSE). The value of this object MUST be retained across reinitializations of the management system." REFERENCE "8.6.5.1, 8.6.5.1.2, 12.31.3" DEFVAL { false } ::= { ieee8021PSFPStreamGateEntry 26} ieee8021PSFPGateClosedDueToInvalidRx OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "The PSFPGateClosedDueToInvalidRx object contains a Boolean value that indicates whether, if the PSFPGateClosedDueToInvalidRx function is enabled, all frames are to be discarded (TRUE) or not (FALSE). The value of this object MUST be retained across reinitializations of the management system." REFERENCE "8.6.5.1, 8.6.5.1.2, 12.31.3" DEFVAL { false } ::= { ieee8021PSFPStreamGateEntry 27} ieee8021PSFPGateClosedDueToOctetsExceededEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "The PSFPGateClosedDueToOctetsExceededEnable object contains a Boolean value that indicates whether the PSFPGateClosedDueToOctetsExceeded function is enabled (TRUE) or disabled (FALSE). The value of this object MUST be retained across reinitializations of the management system." REFERENCE "8.6.5.1, 8.6.5.1.2, 12.31.3" DEFVAL { false } ::= { ieee8021PSFPStreamGateEntry 28} ieee8021PSFPGateClosedDueToOctetsExceeded OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "The PSFPGateClosedDueToOctetsExceeded parameter contains a Boolean value that indicates whether, if the PSFPGateClosedDueToOctetsExceeded function is enabled, all frames are to be discarded (TRUE) or not (FALSE). The value of this object MUST be retained across reinitializations of the management system." REFERENCE "8.6.5.1, 8.6.5.1.2, 12.31.3" DEFVAL { false } ::= { ieee8021PSFPStreamGateEntry 29} ieee8021PSFPStreamGateEntryRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of the row. The writable columns in a row can not be changed if the row is active. All columns MUST have a valid value before a row can be activated. " ::= { ieee8021PSFPStreamGateEntry 30 } -- ============================================================= -- The ieee8021PSFPFlowMeterParameters subtree -- This subtree defines the objects necessary for the management -- of the flow meters for IEEE Std 802.1Q. -- ============================================================= -- ============================================================= -- the ieee8021PSFPFlowMeterTable -- ============================================================= ieee8021PSFPFlowMeterTable OBJECT-TYPE SYNTAX SEQUENCE OF Ieee8021PSFPFlowMeterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains the per-meter instance manageable parameters for flow meters. For a given Bridge component, a row in the table exists for each flow meter instance. All writable objects in this table must be persistent over power up restart/reboot." REFERENCE "8.6.5, 8.6.5.1 12.31.4" ::= { ieee8021PSFPFlowMeterParameters 1 } ieee8021PSFPFlowMeterEntry OBJECT-TYPE SYNTAX Ieee8021PSFPFlowMeterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of objects that contains the manageable parameters for flow meters for a Bridge component." INDEX { ieee8021BridgeBaseComponentId, ieee8021PSFPFlowMeterInstance } ::= { ieee8021PSFPFlowMeterTable 1 } Ieee8021PSFPFlowMeterEntry ::= SEQUENCE { ieee8021PSFPFlowMeterInstance Unsigned32, ieee8021PSFPFlowMeterCIR Unsigned32, ieee8021PSFPFlowMeterCBS Unsigned32, ieee8021PSFPFlowMeterEIR Unsigned32, ieee8021PSFPFlowMeterEBS Unsigned32, ieee8021PSFPFlowMeterCF Integer32, ieee8021PSFPFlowMeterCM INTEGER, ieee8021PSFPFlowMeterDropOnYellow TruthValue, ieee8021PSFPFlowMeterMarkAllFramesRedEnable TruthValue, ieee8021PSFPFlowMeterMarkAllFramesRed TruthValue, ieee8021PSFPFlowMeterEntryRowStatus RowStatus } ieee8021PSFPFlowMeterInstance OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The FlowMeterInstance parameter is an index into the FlowMeterTable. The value of this object MUST be retained across reinitializations of the management system." REFERENCE "8.6.5.1, 12.31.4" ::= { ieee8021PSFPFlowMeterEntry 1} ieee8021PSFPFlowMeterCIR OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "The FlowMeterCIR parameter contains an integer value that represents the CIR value for the flow meter, in bit/s. The value of this object MUST be retained across reinitializations of the management system." REFERENCE "8.6.5.1, 12.31.4" ::= { ieee8021PSFPFlowMeterEntry 2} ieee8021PSFPFlowMeterCBS OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "The FlowMeterCBS parameter contains an integer value that represents the CBS value for the flow meter, in octets. The value of this object MUST be retained across reinitializations of the management system." REFERENCE "8.6.5.1, 12.31.4" ::= { ieee8021PSFPFlowMeterEntry 3} ieee8021PSFPFlowMeterEIR OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "The FlowMeterEIR parameter contains an integer value that represents the EIR value for the flow meter, in bit/s. The value of this object MUST be retained across reinitializations of the management system." REFERENCE "8.6.5.1, 12.31.4" ::= { ieee8021PSFPFlowMeterEntry 4} ieee8021PSFPFlowMeterEBS OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "The FlowMeterEBS parameter contains an integer value that represents the EBS value for the flow meter, in octets. The value of this object MUST be retained across reinitializations of the management system." REFERENCE "8.6.5.1, 12.31.4" ::= { ieee8021PSFPFlowMeterEntry 5} ieee8021PSFPFlowMeterCF OBJECT-TYPE SYNTAX Integer32 (0..1) MAX-ACCESS read-create STATUS current DESCRIPTION "The FlowMeterCF parameter contains an integer value that represents the CF value for the flow meter, as an integer value 0 or 1. The value of this object MUST be retained across reinitializations of the management system." REFERENCE "8.6.5.1, 12.31.4" ::= { ieee8021PSFPFlowMeterEntry 6} ieee8021PSFPFlowMeterCM OBJECT-TYPE SYNTAX INTEGER {colorBlind(1), colorAware(2)} MAX-ACCESS read-create STATUS current DESCRIPTION "The FlowMeterCM parameter contains an integer value that represents the CM value for the flow meter, as an enumerated value indicating colorBlind(1) or colorAware(2). The value of this object MUST be retained across reinitializations of the management system." REFERENCE "8.6.5.1, 12.31.4" ::= { ieee8021PSFPFlowMeterEntry 7} ieee8021PSFPFlowMeterDropOnYellow OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "The FlowMeterDropOnYellow parameter contains a Boolean value that indicates whether yellow frames are dropped (TRUE) or have drop_eligible set to TRUE (FALSE). The value of this object MUST be retained across reinitializations of the management system." REFERENCE "8.6.5.1, 12.31.4" ::= { ieee8021PSFPFlowMeterEntry 8} ieee8021PSFPFlowMeterMarkAllFramesRedEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "The FlowMeterMarkAllFramesRedEnable parameter contains a Boolean value that indicates whether the MarkAllFramesRed function is enabled (TRUE) or disabled (FALSE). The value of this object MUST be retained across reinitializations of the management system." REFERENCE "8.6.5.1, 8.6.5.1.3, 12.31.4" DEFVAL { false } ::= { ieee8021PSFPFlowMeterEntry 9} ieee8021PSFPFlowMeterMarkAllFramesRed OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "The FlowMeterMarkAllFramesRed parameter contains a Boolean value that indicates whether, if the MarkAllFramesRed function is enabled, all frames are to be discarded (TRUE) or not (FALSE). The value of this object MUST be retained across reinitializations of the management system." REFERENCE "8.6.5.1, 8.6.5.1.3, 12.31.4" DEFVAL { false } ::= { ieee8021PSFPFlowMeterEntry 10} ieee8021PSFPFlowMeterEntryRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of the row. The writable columns in a row can not be changed if the row is active. All columns MUST have a valid value before a row can be activated. " ::= { ieee8021PSFPFlowMeterEntry 11 } -- ============================================================= -- The ieee8021PSFPStreamParameters subtree -- This subtree defines the objects necessary for the management -- of the flow meters for IEEE Std 802.1Q. -- ============================================================= -- ============================================================= -- the ieee8021PSFPStreamParameterTable -- ============================================================= ieee8021PSFPStreamParameterTable OBJECT-TYPE SYNTAX SEQUENCE OF Ieee8021PSFPStreamParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains per-Bridge component manageable parameters for PSFP. A row in the table exists for each Bridge component. All writable objects in this table must be persistent over power up restart/reboot." REFERENCE "8.6.5, 8.6.5.1 12.31.4" ::= { ieee8021PSFPStreamParameters 1 } ieee8021PSFPStreamParameterEntry OBJECT-TYPE SYNTAX Ieee8021PSFPStreamParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of objects that contains the manageable parameters for flow meters for a Bridge component." INDEX { ieee8021BridgeBaseComponentId } ::= { ieee8021PSFPStreamParameterTable 1 } Ieee8021PSFPStreamParameterEntry ::= SEQUENCE { ieee8021PSFPMaxStreamFilterInstances Unsigned32, ieee8021PSFPMaxStreamGateInstances Unsigned32, ieee8021PSFPMaxFlowMeterInstances Unsigned32, ieee8021PSFPSupportedListMax Unsigned32 } ieee8021PSFPMaxStreamFilterInstances OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The MaxStreamFilterInstances parameter defines the maximum number of stream filter instances that are supported by this Bridge component." REFERENCE "8.6.5.1, 12.31.2" ::= { ieee8021PSFPStreamParameterEntry 1} ieee8021PSFPMaxStreamGateInstances OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The MaxStreamGateInstances parameter defines the maximum number of stream gate instances that are supported by this Bridge component." REFERENCE "8.6.5.1, 12.31.3" ::= { ieee8021PSFPStreamParameterEntry 2} ieee8021PSFPMaxFlowMeterInstances OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The MaxFlowMeterInstances parameter defines the maximum number of flow meter instances that are supported by this Bridge component." REFERENCE "8.6.5.1, 12.31.4" ::= { ieee8021PSFPStreamParameterEntry 3} ieee8021PSFPSupportedListMax OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The SupportedListMax parameter defines the The maximum value supported by this Bridge component of the AdminControlListLength and OperControlListLength parameters." REFERENCE "8.6.5.1, 12.31.3" ::= { ieee8021PSFPStreamParameterEntry 4} -- ============================================================= -- IEEE8021 PSFP MIB - Conformance Information -- ============================================================= ieee8021PSFPCompliances OBJECT IDENTIFIER ::= { ieee8021PSFPConformance 1 } ieee8021PSFPGroups OBJECT IDENTIFIER ::= { ieee8021PSFPConformance 2 } -- ============================================================= -- units of conformance -- ============================================================= -- ============================================================= -- the ieee8021PSFPObjectsGroup group -- ============================================================= ieee8021PSFPObjectsGroup OBJECT-GROUP OBJECTS { ieee8021PSFPStreamHandleSpec, ieee8021PSFPPrioritySpec, ieee8021PSFPStreamGateInstanceID, ieee8021PSFPFilterSpecificationList, ieee8021PSFPMatchingFramesCount, ieee8021PSFPPassingFramesCount, ieee8021PSFPNotPassingFramesCount, ieee8021PSFPPassingSDUCount, ieee8021PSFPNotPassingSDUCount, ieee8021PSFPREDFramesCount, ieee8021PSFPStreamBlockedDueToOversizeFrameEnable, ieee8021PSFPStreamBlockedDueToOversizeFrame, ieee8021PSFPStreamFilterEntryRowStatus, ieee8021PSFPGateEnabled, ieee8021PSFPAdminGateStates, ieee8021PSFPOperGateStates, ieee8021PSFPAdminControlListLength, ieee8021PSFPOperControlListLength, ieee8021PSFPAdminControlList, ieee8021PSFPOperControlList, ieee8021PSFPAdminCycleTimeNumerator, ieee8021PSFPAdminCycleTimeDenominator, ieee8021PSFPOperCycleTimeNumerator, ieee8021PSFPOperCycleTimeDenominator, ieee8021PSFPAdminCycleTimeExtension, ieee8021PSFPOperCycleTimeExtension, ieee8021PSFPAdminBaseTime, ieee8021PSFPOperBaseTime, ieee8021PSFPConfigChange, ieee8021PSFPConfigChangeTime, ieee8021PSFPTickGranularity, ieee8021PSFPCurrentTime, ieee8021PSFPConfigPending, ieee8021PSFPConfigChangeError, ieee8021PSFPAdminIPV, ieee8021PSFPOperIPV, ieee8021PSFPGateClosedDueToInvalidRxEnable, ieee8021PSFPGateClosedDueToInvalidRx, ieee8021PSFPGateClosedDueToOctetsExceededEnable, ieee8021PSFPGateClosedDueToOctetsExceeded, ieee8021PSFPStreamGateEntryRowStatus, ieee8021PSFPFlowMeterCIR, ieee8021PSFPFlowMeterCBS, ieee8021PSFPFlowMeterEIR, ieee8021PSFPFlowMeterEBS, ieee8021PSFPFlowMeterCF, ieee8021PSFPFlowMeterCM, ieee8021PSFPFlowMeterDropOnYellow, ieee8021PSFPFlowMeterMarkAllFramesRedEnable, ieee8021PSFPFlowMeterMarkAllFramesRed, ieee8021PSFPFlowMeterEntryRowStatus, ieee8021PSFPMaxStreamFilterInstances, ieee8021PSFPMaxStreamGateInstances, ieee8021PSFPMaxFlowMeterInstances, ieee8021PSFPSupportedListMax } STATUS current DESCRIPTION "Objects that allow management of PSFP." ::= { ieee8021PSFPGroups 1 } -- ============================================================= -- compliance statements -- ============================================================= ieee8021PSFPCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for devices supporting PSFP. Support of the objects defined in this MIB module also requires support of the IEEE8021-BRIDGE-MIB; the provisions of 17.3.2 apply to implementations claiming support of this MIB. " MODULE -- this module MANDATORY-GROUPS { ieee8021PSFPObjectsGroup } ::= { ieee8021PSFPCompliances 1 } END