Thread Links Date Links
Thread Prev Thread Next Thread Index Date Prev Date Next Date Index

Re: [STDS-802-11-TGAX] TGax Teleconference 2018-03-28 (Proposed Agenda)



If we have any time left today, we could also discuss the following:

- CID 20637 [@Eldad].  I suggest the following resolution:

REVISED
In the table in 6.3.3.3.2 delete "dot11HEOptionImplemented is true and ".
In the table in 6.3.7.3.2, 6.3.7.5.2, 6.3.8.3.2, 6.3.8.5.2 delete " if dot11HEOptionImplemented is true; otherwise not present".
In Tables 9-34, 9-37, 9-39, 9-41 delete " if dot11HEOptionImplemented is true; otherwise it is not present".


- CID 20758.  The Proposed Change is clear and specific, but I see the subclause reference is wrong:

At the end of the referenced subclaus[e] [11.23.1] add "A TDLS STA shall not transmit a triggering PPDU and shall not transmit an HE MU PPDU to more than one STA."

I suggest the following resolution:

REVISED
Add the proposed text at the end of Subclause 11.21.1.

- CID 20771.  This is marked as Submission Required, but the Proposed Change is clear and specific:

Add a subclause "Protection" stating "A TXOP holder that transmits an HE ER PPDU in a TXOP shall transmit an RTS frame or MU-RTS Trigger frame at the start of the TXOP."

I suggest the following resolution:

ACCEPTED

- CID 20850.  This is marked as Submission Required, but the Proposed Change is clear and specific:

Delete the cited text ["An HE STA shall not send a Control Wrapper frame to another HE STA."] at the referenced location [s10.9, 248.43]

I suggest the following resolution:

ACCEPTED

Thanks,

Mark

--
Mark RISON, Standards Architect, WLAN         English/Esperanto/Français
Samsung Cambridge Solution Centre
Innovation Park, Cambridge CB4 0DS                 Tel: +44 1223  434600
ROYAUME UNI              http://www.samsungscsc-careers.com/about-us.php

To unsubscribe from the STDS-802-11-TGAX list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGAX&A=1