Yair -

Let's discuss this on the call. My scheme does not detect your Option 2b as different from Type 2a.

Dave

On Oct 1, 2014, at 4:00 AM, Darshan, Yair <YDarshan@xxxxxxxxxxxxx> wrote:

> Thanks Dave,
> I couldn't  find the part that prevents from 4P PSE to operate option 2 PD with Type 1/2 maximum power which although they have bot valid signatures on A and B but is limited to power only A or B.
> Yair
> 
> -----Original Message-----
> From: Dave Dwelley [mailto:ddwelley@xxxxxxxxxx] 
> Sent: Wednesday, October 01, 2014 7:36 AM
> To: STDS-802-3-4PPOE@xxxxxxxxxxxxxxxxx
> Subject: [802.3_4PPOE] 4PID presentation for tomorrow morning
> 
> All -
> 
> Here's the presentation I'm planning to discuss in tomorrow's 4PID meeting.
> 
> Dave