[802.3_4PPOE] Comment 128 text



All,

The following statement is an alternate, simpler way to address the problem addressed in comment 128, where
a PSE's Allocation is less than that seen by the PD.

"A PSE shall not initiate power provision to a PD with an allocation of Class 1,2,5, or 7 when
the allocation is less than the maximum power requested by the PD."

Regards,