PROPOSED ACCEPT IN PRINCIPLE. Add MDIO registers to accommodate the larger number of bits in the PD power fields as shown in , by making the following changes: (references to “Stewart comment i-40_41 presentation” below are to this URL). Change the edit to clause 45.2.9 Power Unit Registers with editing instructions: “modify Table 45-211p Power Unit MMD Registers to add two rows for registers 13.3 and 13.4 below the existing row for register 13.2 as shown on slide 3 of Stewart comment i-40_41 presentation” And add new subclause 45.2.9.4 PoDL PSE Status 3 Register (Register 13.3) and 45.2.9.4.1 PD Assigned Power (13.3.11:0) to the draft, with editing instruction: “Insert New subclause 45.2.9.4 PoDL PSE Status 3 Register (Register 13.3) after 45.2.9.3 and add text under subclause 45.2.9.4 as below:” “The PoDL PSE Status 3 Register is defined if cable resistance measurement is supported” “And Insert New subclause 45.2.9.4.1 PD Assigned Power (13.3.11:0) after 45.2.9.4 and insert text under subclause 45.2.9.4.1 PD Extended Class (13.3.11:0) as below: “The PD Assigned Power is the maximum average available power at the PD PI.” Add Table 45-342 PoDL PSE Status 3 Register (Register 13.3) under clause 45.2.9.4 to denote PD Assigned Power as shown on slide 4 of Stewart comment i-40_41 presentation. And add new subclause 45.2.9.5 PoDL PSE Status 4 Register (Register 13.4) and 45.2.9.5.1 PD Requested Power (13.4.11:0) to the draft, with editing instruction: “Insert New subclause 45.2.9.5 PoDL PSE Status 4 Register (Register 13.4) after 45.2.9.4 and add text under subclause 45.2.9.5 as below:” “The PoDL PSE Status 4 Register is defined if cable resistance measurement is supported” “And Insert New subclause 45.2.9.5.1 PD Requested Power (13.4.11:0) after 45.2.9.5” “Insert text under subclause 45.2.9.5.1 PD Extended Class (13.4.11:0) as below: “The PD Requested Power is the requested average available power at the PD PI.” Add Table 45-343 PoDL PSE Status 4 Register (Register 13.4) under clause 45.2.9.5 to denote PD Assigned Power as shown on slide 5 of Stewart comment i-40_41 presentation.