Thread Links Date Links
Thread Prev Thread Next Thread Index Date Prev Date Next Date Index

[STDS-802-3-EPOC] ePoll results for: Unofficial IEEE P802.3bn Task Force eStraw Poll #tdd_3



Online straw poll closed at 2013-07-05 18:00:00 for:

Unofficial IEEE P802.3bn Task Force eStraw Poll #tdd_3
4K FFT minimum downstream time window Question: (formatted for text):

"For the 4k FFT version what value do you believe should be the
minimum configurable downstream time window (measured in symbols
including cyclic prefix)?  (Reference: TDD sub-Task Force minutes
6/24/13 and TDD Cycle (updated 6/24/13). )"
----------------------------------------------------
Vote type: Single answer selection per voter.
Summary of votes per answer (percent of total):
0)   1 symbol = 20.9375 to 25 usec =   0 (0.0%)
1)   2 symbols = 41.875 to 50 usec =   0 (0.0%)
2)   4 symbols = 83.75 to 100 usec =   3 (75.0%)
3)   8 symbols = 167.5 to 200 usec =   1 (25.0%)

  Total votes =   4

________________________________________________________________________

To unsubscribe from the STDS-802-3-EPOC list, click the following link:
https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-3-EPOC&A=1
"Full Name",Email,"Voting Member","Vote Date / Time",Answer,Comments
"Steve Shellhammer",sshellha@xxxxxxxxxxxxxxxx,Y,"2013-06-24 16:53:15",single:::2::,
"Bill Powell",bill.powell@xxxxxxxxxxxxxxxxxx,Y,"2013-06-25 09:48:15",single:::2::,
"George Hart",george.hart@xxxxxxxxxxxxxx,N,"2013-06-25 13:50:25",single:::2::,
"Leo Montreuil",leo.montreuil@xxxxxxxxxxxx,Y,"2013-06-27 07:13:16",single::::3:,


________________________________________________________________________

To unsubscribe from the STDS-802-3-EPOC list, click the following link:
https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-3-EPOC&A=1