Thread Links Date Links
Thread Prev Thread Next Thread Index Date Prev Date Next Date Index

Re: [HSSG] 40G MAC Rate Discussion



Bruce

I stated exclude the PHY IC.  10G PHY ICs with EDC dissipate little more than 1W PD (linear) and
one without EDC (limiting) dissipate little bit less than 1W.

Thanks,
Ali

Bruce Tolley wrote:
Ali
Good point

Just to be clear, your PD number excludes the power/thermal burden of
any associated ICs, for example XAUI serdes and XAUI to XFI/SFI gasket
chip.

Bruce

Bruce Tolley
Vice President, Marketing
Solarflare Communications
9501 Jeronimo Road,Suite 250
Irvine, California 92618
ip phone 949 581 6830 X2014
mobile 650 862 1074
btolley@solarflare.com

-----Original Message-----
From: Ali Ghiasi [mailto:aghiasi@BROADCOM.COM] 
Sent: Tuesday, April 10, 2007 12:00 PM
To: STDS-802-3-HSSG@listserv.ieee.org
Subject: Re: [HSSG] 40G MAC Rate Discussion

Mikael

Market adoption is the function of power, size, cost, and availability.

Any solution
which increases dramatically power consumption of a port or reduce total

face plate
data capacity will face market adoption.  I like to put out what is 
possible currently with
SFP+:
    - 1W PD for SR (300 m) and LR (10 km) reach
    - 48 ports of 10Gig on a 1U height chassis
The 40G and 100G solution should be benchmark against these target, 
unless they can
offer power and density advantage their market adaptation will be 
challenged.

I know there is readily available solution based on QSFP that could do
40G copper with twin-ax cables.  Copper solution are very attractive for

sub-10m as
they offer order of magnitude cost advantage.  Longer reach cable not as

attractive as
you have to use heavier gage which increase the cable size, weight, 
cost, and the complexity of
receiver increases.

Thanks,
Ali

Mikael Abrahamsson wrote:
  
On Tue, 10 Apr 2007, Paul Kolesar wrote:

    
If this relationship is true and from what I know of such things, 
then the
cost to the end user of an installed, tested, warranted,
      
typical-length,
  
12-fiber, MM structured cabling link, consisting of a cable 
terminated at
      
Could you please do a comparison relating to 10GBASE-T as well?

I do believe volume takes off when there is a copper alternative (due 
to lower cost both for cabling and equipment), I am interested in how 
this would relate in cost to a 40G fiber alternative, and/or if there 
is a proposed 40G copper variant.

    



  

begin:vcard
fn:Ali Ghiasi
n:Ghiasi;Ali
org:Broadcom;HSIP
adr;dom:;;3151 Zanker Road;San Jose;CA;95014
email;internet:aghiasi@broadcom.com
title:Chief Architect
tel;work:(408)922-7423
tel;cell:(949)290-8103
version:2.1
end:vcard