Re: [STDS-802-11-TGBF] TGbf meeting on February 28, March 1 and 3



Hi Solomon

 

Thanks for your further feedback.

For the first one, Ive also intended to be open while it is missing. I’ll add TBD field.

For the second one, previously I added the protected part,

but since there were no enough discussions for which category we have for Request/Response frames (based on comments), it is TBD now.

I think we can resolve it in the next stage. Basically, I agree with “protected” of course.

 

Thanks

Best Regards

Insun

 

 

Hi Insun,

Thank you for your work in compiling the text.

I have two comments.

- It may more be parameters for negotiation like bandwidth and number of spatial streams, but your approach limits the Sensing Measurement Parameters field format to three parameters. So, another field needed to add more parameters. Why not keep this field open?

- You defined the setup frames in the Public action category. They shall be in the Protected Dual of Public Action also to be protected. I would suggest adding it to your document.

 

Best  regards,

Solomon Trainin

+972547885738

 

From: 장인선 <insun.jang@xxxxxxx>
Sent: Monday, March 7, 2022 1:50 AM
To:
STDS-802-11-TGBF@xxxxxxxxxxxxxxxxx
Subject: Re: [STDS-802-11-TGBF] TGbf meeting on February 28, March 1 and 3

 

WARNING: This email originated from outside of Qualcomm. Please be wary of any links or attachments, and do not enable macros.

Hi All

 

I made a quick change for the PDT below by removing “subtype” to align with other PDTs (i.e., termination/SBP) which have defined different action field values.

https://mentor.ieee.org/802.11/dcn/22/11-22-0229-05-00bf-pdt-for-sensing-measurement-setup.docx

Please note that it does not change any intention while just having different action field values and let me know if you have opinions on that.

 

Thanks

Best Regards

Insun

 

From: 장인선 [mailto:insun.jang@xxxxxxx]
Sent: Monday, February 28, 2022 11:44 PM
To: 'Hanxiao (Tony, WT Lab)'; 'STDS-802-11-TGBF@xxxxxxxxxxxxxxxxx'
Subject: RE: [STDS-802-11-TGBF] TGbf meeting on February 28, March 1 and 3

 

Hi Tony,

 

Could you please add the following PDT to the motion list?

- 22/0229r4, PDT for Sensing Measurement Setup

SP Results (Y/N/A): 22/0/15

 

Thanks

Best Regards

Insun

 

From: Hanxiao (Tony, WT Lab) [mailto:0000177ab8f731c4-dmarc-request@xxxxxxxxxxxxxxxxx]
Sent: Friday, February 25, 2022 4:14 PM
To:
STDS-802-11-TGBF@xxxxxxxxxxxxxxxxx
Subject: [STDS-802-11-TGBF] TGbf meeting on February 28, March 1 and 3

 

Dear all,

This is a reminder and call for submissions for the upcoming meeting on:

     February   28  (Monday),   9am   - 11:00am ET        March        1    (Tuesday),  9am - 11:00am ET *Motion

     March       3    (Thursday), 10pm - 12:00am ET

 

Please note:

1.     Please send the agenda request at least 24 hours prior to the call, following the format below:

     DCN, Title, Author (affiliation), Time duration

2.     I will cancel the call if there is no request received 24 hours prior to a call.

3.     Please upload your submissions (revision 0) on mentor 24 hours prior to the meeting so that members would have a chance to review those submissions offline. Otherwise,

a.     If there is not enough time during the meeting, the presentation will be delayed to the next meeting.

b.     If there is enough time during the meeting, the presentation will be moved to the end of the queue and be presented in the end. However, any related SP should be delayed to the next meeting.

4.     Please send the motion request (with related DCN, and SP result) around 10+5 days before the meeting (for teleconference, not for Plenary or Interim meeting), so that the TG chair could send the 10 day advance notice to the 802.11 reflector, after getting the approval from the WG chair.

5.      Dial-in information:

 

February   28  (Monday)
Join the Webex meeting here: https://ieeesa.webex.com/ieeesa/j.php?MTID=m6578f9f5432279b17889bbe051feb7df

Meeting number: 233 941 45840

Meeting password: wireless (94735377 from phones and video systems)

Join by phone: Tap to call in from a mobile device (attendees only) +1-408-418-9388 USA Toll
Global call-in numbers

Access code: 233 941 45840

Join from a video system or application Dial 23394145840@xxxxxxxxxxxxxxxx You can also dial 173.243.2.68 and enter your meeting number.

Join using Microsoft Lync or Microsoft Skype for Business Dial 23394145840.ieeesa@xxxxxxxxxxxxxx

Need help? Go to http://help.webex.com

 

 

March  1  (Tuesday)
Join the Webex meeting here: https://ieeesa.webex.com/ieeesa/j.php?MTID=mec9ffde3db8f82e34cb23fa1d20b902d

Meeting number: 234 827 03819

Meeting password: wireless (94735377 from phones and video systems)

Join by phone: Tap to call in from a mobile device (attendees only) +1-408-418-9388 USA Toll
Global call-in numbers

Access code: 234 827 03819

Join from a video system or application Dial 23482703819@xxxxxxxxxxxxxxxx You can also dial 173.243.2.68 and enter your meeting number.

Join using Microsoft Lync or Microsoft Skype for Business Dial 23482703819.ieeesa@xxxxxxxxxxxxxx

Need help? Go to http://help.webex.com

 

 

March  3 (Thursday)

Join the Webex meeting here: https://ieeesa.webex.com/ieeesa/j.php?MTID=m2060262528e8d8b1c1f7cebaa5ff7678

Meeting number: 233 847 26895

Meeting password: wireless (94735377 from phones and video systems)

Join by phone: Tap to call in from a mobile device (attendees only) +1-408-418-9388 USA Toll
Global call-in numbers

Access code: 233 847 26895

Join from a video system or application Dial 23384726895@xxxxxxxxxxxxxxxx You can also dial 173.243.2.68 and enter your meeting number.

Join using Microsoft Lync or Microsoft Skype for Business Dial 23384726895.ieeesa@xxxxxxxxxxxxxx

Need help? Go to http://help.webex.com

 

Best Regards : )

Tony Xiao Han


To unsubscribe from the STDS-802-11-TGBF list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBF&A=1


To unsubscribe from the STDS-802-11-TGBF list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBF&A=1


To unsubscribe from the STDS-802-11-TGBF list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBF&A=1


To unsubscribe from the STDS-802-11-TGBF list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBF&A=1