Thread Links | Date Links | ||||
---|---|---|---|---|---|
Thread Prev | Thread Next | Thread Index | Date Prev | Date Next | Date Index |
Hi Gaurang,
Thank you very much for preparing this document.
1. The Mode Tuple field overlaps with the definition in 25/882.
2. The Countdown appears to be applied at the BSS level, which prevents consecutive updates for different modes.
While this may not be an ideal design,
it would be helpful to explicitly state that no additional updates are allowed when the Countdown has a value greater than 0 and less than 127.
Thanks,
BRs,
Seongho.
--------- Original Message ---------
Sender : Gaurang Naik <0000305a2f8ce933-dmarc-request@xxxxxxxxxxxxxxxxx>
Date : 2025-07-23 23:56 (GMT+9)
Title : Re: [STDS-802-11-TGBN] MAC CR document for enablement/disablement of modes on AP side
Hello all,
Could you please use this thread to provide your feedback/comments on document 1091r3?
Thanks,
Gaurang
From: Gaurang Naik <gnaik@xxxxxxxxxxxxxxxx>
Sent: Wednesday, July 23, 2025 3:44 AM
To: STDS-802-11-TGBN@xxxxxxxxxxxxxxxxx <stds-802-11-tgbn@xxxxxxxxxxxxxxxxx>
Subject: Re: MAC CR document for enablement/disablement of modes on AP side
Hello all,
11-25/1091r3 is now on mentor.
Thanks,
Gaurang
From: Gaurang Naik <gnaik@xxxxxxxxxxxxxxxx>
Sent: Tuesday, July 22, 2025 10:29 PM
To: STDS-802-11-TGBN@xxxxxxxxxxxxxxxxx <stds-802-11-tgbn@xxxxxxxxxxxxxxxxx>
Subject: Re: MAC CR document for enablement/disablement of modes on AP side
Hello all,
11-25/1091r2 is now on mentor.
Thanks,
Gaurang
From: Gaurang Naik <gnaik@xxxxxxxxxxxxxxxx>
Sent: Tuesday, July 22, 2025 2:34 PM
To: STDS-802-11-TGBN@xxxxxxxxxxxxxxxxx <stds-802-11-tgbn@xxxxxxxxxxxxxxxxx>
Subject: Re: MAC CR document for enablement/disablement of modes on AP side
Hello all,
Uploaded 11-25/1091r1 based on received offline feedback.
Thanks,
Gaurang
From: Gaurang Naik <gnaik@xxxxxxxxxxxxxxxx>
Sent: Monday, July 21, 2025 3:24 PM
To: STDS-802-11-TGBN@xxxxxxxxxxxxxxxxx <stds-802-11-tgbn@xxxxxxxxxxxxxxxxx>
Subject: MAC CR document for enablement/disablement of modes on AP side
Hello all,
I have uploaded CR 11-25/1091r0 that resolves CIDs on enablement/disablement of UHR features on the AP side. The CR document resolves the following CIDs:
2512, 2479, 2692, 913, 3405, 2473, 3652, 3680, 2124, 3802, 3801
Please let me know if you have any feedback or suggestions.
Thanks,
Gaurang
To unsubscribe from the STDS-802-11-TGBN list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBN&A=1
|