Hi Jay,

 

Thanks for the comment. Good point. I’ll add some text similar to the clean-up text below in the preparation phase 37.16.5.2 but apply to the current AP MLD instead.

 

”If an ST execution request from the non-AP MLD requesting SMD BSS transition to a target

AP MLD is not received by the current AP MLD or the target AP MLD within t

• The setup links at the target AP MLD.

• The transferred context at the target AP MLD.

• The newly derived PTK if the Per-AP MLD PTK mode is used.”

 

BR,

Duncan

 

From: yang.zhijie@xxxxxxxxxx <yang.zhijie@xxxxxxxxxx>
Sent: Sunday, January 11, 2026 7:18 PM
To: 00002b3e54cff3e2-dmarc-request@xxxxxxxxxxxxxxxxx
Cc: STDS-802-11-TGBN@xxxxxxxxxxxxxxxxx
Subject: Re: [STDS-802-11-TGBN] CR for seamless roaming UL suspension and state changes

 

WARNING: This email originated from outside of Qualcomm. Please be wary of any links or attachments, and do not enable macros.

Hi Duncan,

 

Thanks for your efforts on this.

 

Regarding the following proposed text. I think we need some texts to clarify whether the context in the current AP MLD  is removed or not, what's your opinion?

 

(#10413)When the current AP MLD receives a notification from the current AP MLD  via the backhaul  indicating that the non-AP MLD has transitioned to the target AMLD , the current AP MLD  shall remove all setup links with the non-AP MLD and enter State 1 with the non-AP MLD .

 

 

 

 

 

Thanks

 

Best Regards

 

Jay Yang (杨志杰)

 

 

Original

Date: 20260112 00:30

Subject: [STDS-802-11-TGBN] CR for seamless roaming UL suspension and state changes

Dear Seamless Roaming TTT members,

 

I’ve drafted this CR to address the UL data suspension and  MLD state change. Could you please review it and let me know if you have any feedback?

Hope to see you in Victoria!

 