Re: [STDS-802-11-TGBP] PDT AMP Service Period



Hi Ian,

 

Thanks for the PDT.

 

While the recent motions does mention 2* maximum clock drift period, I think the text update can be greatly simplified, if we simply update the definition of maximum clock drift period as below. Then there is no need to update the rest of the text or figure.

 

The maximum clock drift period is defined as twice the clock drift corresponding to a maximum receiver clock inaccuracy for an Active Tx or bistatic Backscatter non-AP AMP STA of 10,000ppm .

 

Best Regards,

Rojan Chitrakar

 

From: Sanket Kalamkar <000033b8f79f2eb4-dmarc-request@xxxxxxxxxxxxxxxxx>
Sent: Tuesday, July 28, 2026 10:22 AM
To: STDS-802-11-TGBP@xxxxxxxxxxxxxxxxx
Subject: Re: [STDS-802-11-TGBP] PDT AMP Service Period

 

Hi Ian,

 

Thanks for your work on the PDT. Some comments are attached.

 

Best,

Sanket

 


From: Ian Bajaj <ian@xxxxxxxx>
Sent: Monday, July 27, 2026 1:51 PM
To: STDS-802-11-TGBP@xxxxxxxxxxxxxxxxx <STDS-802-11-TGBP@xxxxxxxxxxxxxxxxx>
Subject: [STDS-802-11-TGBP] PDT AMP Service Period

 

WARNING: This email originated from outside of Qualcomm. Please be wary of any links or attachments, and do not enable macros.

Hi Bo,

Please also add PDT AMP Service Period to the queue for the upcoming teleconference. I need only 2 minutes.

 

Hi TTT members,

Please feedback if there are any comments:

 

Thanks and regards

Ian

 