IEEE8023-DOT3-LLDP-EXT-V2-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Unsigned32, Integer32, org FROM SNMPv2-SMI TruthValue FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF ifGeneralInformationGroup FROM IF-MIB lldpV2LocPortIfIndex, lldpV2RemLocalIfIndex, lldpV2RemTimeMark, lldpV2RemLocalDestMACAddress, lldpV2RemIndex, lldpV2PortConfigEntry FROM LLDP-V2-MIB -- http://www.ieee802.org/1/files/public/MIBs/LLDP-V2-MIB-200906080000Z.txt LldpV2PowerPortClass FROM LLDP-V2-TC-MIB -- http://www.ieee802.org/1/files/public/MIBs/LLDP-V2-TC-MIB-200906080000Z.txt ; ieee8023lldpV2Xdot3MIB MODULE-IDENTITY LAST-UPDATED "201304110000Z" -- April 11, 2013 ORGANIZATION "IEEE 802.3 Working Group" CONTACT-INFO "WG-URL: http://www.ieee802.org/3/index.html WG-EMail: STDS-802-3-MIB@LISTSERV.IEEE.ORG Contact: Howard Frazier Postal: 3151 Zanker Road San Jose, CA 95134 USA Tel: +1.408.922.8164 E-mail: hfrazier@broadcom.com" DESCRIPTION "The LLDP Management Information Base extension module for IEEE 802.3 organizationally defined discovery information." REVISION "201304110000Z" -- April 11, 2013 DESCRIPTION "Revision, based on an earlier version in IEEE Std 802.3.1-2011." REVISION "201102020000Z" -- February 2, 2011 DESCRIPTION "This revision incorporated changes to the MIB module to add objects to support management of Energy Efficient Ethernet (EEE) and Enhanced DTE Power via the MDI (PoE+)." ::= { org ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802)ieee802dot3(3) ieee802dot3dot1mibs(1) 5 } ------------------------------------------------------------------------------ ------------------------------------------------------------------------------ -- -- Organizationally Defined Information Extension - IEEE 802.3 -- ------------------------------------------------------------------------------ ------------------------------------------------------------------------------ lldpV2Xdot3Objects OBJECT IDENTIFIER ::= { ieee8023lldpV2Xdot3MIB 1 } -- LLDP IEEE 802.3 extension MIB groups lldpV2Xdot3Config OBJECT IDENTIFIER ::= { lldpV2Xdot3Objects 1 } lldpV2Xdot3LocalData OBJECT IDENTIFIER ::= { lldpV2Xdot3Objects 2 } lldpV2Xdot3RemoteData OBJECT IDENTIFIER ::= { lldpV2Xdot3Objects 3 } ------------------------------------------------------------------------------ -- IEEE 802.3 - Configuration ------------------------------------------------------------------------------ -- -- Version 2 of lldpV2Xdot3PortConfigTable -- supports use of multiple destination MAC addresses -- lldpV2Xdot3PortConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF LldpV2Xdot3PortConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that controls selection of LLDP TLVs to be transmitted on individual ports." ::= { lldpV2Xdot3Config 1 } lldpV2Xdot3PortConfigEntry OBJECT-TYPE SYNTAX LldpV2Xdot3PortConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "LLDP configuration information that controls the transmission of IEEE 802.3 organizationally defined TLVs on LLDP transmission capable ports. This configuration object augments the lldpV2PortConfigEntry of the LLDP-MIB, therefore it is only present along with the port configuration defined by the associated lldpV2PortConfigEntry entry. Each active lldpV2Xdot3PortConfigEntry is restored from non-volatile storage (along with the corresponding lldpV2PortConfigEntry) after a re-initialization of the management system." AUGMENTS { lldpV2PortConfigEntry } ::= { lldpV2Xdot3PortConfigTable 1 } LldpV2Xdot3PortConfigEntry ::= SEQUENCE { lldpV2Xdot3PortConfigTLVsTxEnable BITS } lldpV2Xdot3PortConfigTLVsTxEnable OBJECT-TYPE SYNTAX BITS { macPhyConfigStatus(0), powerViaMDI(1), unused(2), --avoids re-use of the old link agg bit number maxFrameSize(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The lldpV2Xdot3PortConfigTLVsTxEnable, defined as a bitmap, includes the IEEE 802.3 organizationally defined set of LLDP TLVs whose transmission is allowed by the local LLDP agent by the network management. Each bit in the bitmap corresponds to an IEEE 802.3 subtype associated with a specific IEEE 802.3 optional TLV. The bit 'macPhyConfigStatus(0)' indicates that the LLDP agent should transmit 'MAC/PHY configuration/status TLV'. The bit 'powerViaMDI(1)' indicates that the LLDP agent should transmit 'Power via MDI TLV'. The bit 'unused(2)' is no longer used; this was used for the 'Link Aggregation TLV' in the previous version. The bit 'maxFrameSize(3)' indicates that the LLDP agent should transmit 'Maximum-frame-size TLV'. The default value for lldpV2Xdot3PortConfigTLVsTxEnable object is an empty set, which means no enumerated values are set. The value of this object is restored from non-volatile storage after a re-initialization of the management system." REFERENCE "IEEE Std 802.3 30.12.1.1.1" DEFVAL { { } } ::= { lldpV2Xdot3PortConfigEntry 1 } ------------------------------------------------------------------------------ -- IEEE 802.3 - Local Device Information ------------------------------------------------------------------------------ --- --- lldpV2Xdot3LocPortTable: Ethernet Port AutoNeg/Speed/Duplex --- Information Table --- V2 modified to be indexed by ifIndex. --- lldpV2Xdot3LocPortTable OBJECT-TYPE SYNTAX SEQUENCE OF LldpV2Xdot3LocPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains one row per port of Ethernet port information (as a part of the LLDP 802.3 organizational extension) on the local system known to this agent." ::= { lldpV2Xdot3LocalData 1 } lldpV2Xdot3LocPortEntry OBJECT-TYPE SYNTAX LldpV2Xdot3LocPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a particular port component." INDEX { lldpV2LocPortIfIndex } ::= { lldpV2Xdot3LocPortTable 1 } LldpV2Xdot3LocPortEntry ::= SEQUENCE { lldpV2Xdot3LocPortAutoNegSupported TruthValue, lldpV2Xdot3LocPortAutoNegEnabled TruthValue, lldpV2Xdot3LocPortAutoNegAdvertisedCap OCTET STRING, lldpV2Xdot3LocPortOperMauType Unsigned32 } lldpV2Xdot3LocPortAutoNegSupported OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "The truth value used to indicate whether the given port (associated with the local system) supports Auto-negotiation." REFERENCE "IEEE Std 802.3 30.12.2.1.1" ::= { lldpV2Xdot3LocPortEntry 1 } lldpV2Xdot3LocPortAutoNegEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "The truth value used to indicate whether port Auto-negotiation is enabled on the given port associated with the local system." REFERENCE "IEEE Std 802.3 30.12.2.1.2" ::= { lldpV2Xdot3LocPortEntry 2 } lldpV2Xdot3LocPortAutoNegAdvertisedCap OBJECT-TYPE SYNTAX OCTET STRING(SIZE(2)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the value (bitmap) of the ifMauAutoNegCapAdvertisedBits object (defined in IETF RFC 3636) which is associated with the given port on the local system." REFERENCE "IEEE Std 802.3 30.12.2.1.3" ::= { lldpV2Xdot3LocPortEntry 3 } lldpV2Xdot3LocPortOperMauType OBJECT-TYPE SYNTAX Unsigned32(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "An integer value that indicates the operational MAU type of the given port on the local system. This object contains the integer value derived from the list position of the corresponding dot3MauType as listed in Clause 13 and is equal to the last number in the respective dot3MauType OID. For example, if the ifMauType object is dot3MauType1000BaseTHD which corresponds to {dot3MauType 29}, the numerical value of this field is 29. For MAU types not listed in Clause 13, the value of this field shall be set to zero." REFERENCE "IEEE Std 802.3 30.12.2.1.4" ::= { lldpV2Xdot3LocPortEntry 4 } --- --- --- lldpV2Xdot3LocPowerTable: Power Ethernet Information Table --- V2 modified to be indexed by ifIndex. --- --- lldpV2Xdot3LocPowerTable OBJECT-TYPE SYNTAX SEQUENCE OF LldpV2Xdot3LocPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains one row per port of power Ethernet information (as a part of the LLDP IEEE 802.3 organizational extension) on the local system known to this agent." ::= { lldpV2Xdot3LocalData 2 } lldpV2Xdot3LocPowerEntry OBJECT-TYPE SYNTAX LldpV2Xdot3LocPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a particular port component." INDEX { lldpV2LocPortIfIndex } ::= { lldpV2Xdot3LocPowerTable 1 } LldpV2Xdot3LocPowerEntry ::= SEQUENCE { lldpV2Xdot3LocPowerPortClass LldpV2PowerPortClass, lldpV2Xdot3LocPowerMDISupported TruthValue, lldpV2Xdot3LocPowerMDIEnabled TruthValue, lldpV2Xdot3LocPowerPairControlable TruthValue, lldpV2Xdot3LocPowerPairs Unsigned32, lldpV2Xdot3LocPowerClass Unsigned32, lldpV2Xdot3LocPowerType INTEGER, lldpV2Xdot3LocPowerSource INTEGER, lldpV2Xdot3LocPowerPriority INTEGER, lldpV2Xdot3LocPDRequestedPowerValue Integer32, lldpV2Xdot3LocPSEAllocatedPowerValue Integer32, lldpV2Xdot3LocResponseTime Integer32, lldpV2Xdot3LocReady TruthValue, lldpV2Xdot3LocReducedOperationPowerValue Integer32 } lldpV2Xdot3LocPowerPortClass OBJECT-TYPE SYNTAX LldpV2PowerPortClass MAX-ACCESS read-only STATUS current DESCRIPTION "The value that identifies the port Class of the given port associated with the local system." REFERENCE "IEEE Std 802.3 30.12.2.1.5" ::= { lldpV2Xdot3LocPowerEntry 1 } lldpV2Xdot3LocPowerMDISupported OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "The truth value used to indicate whether the MDI power is supported on the given port associated with the local system." REFERENCE "IEEE Std 802.3 30.12.2.1.6" ::= { lldpV2Xdot3LocPowerEntry 2 } lldpV2Xdot3LocPowerMDIEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "The truth value used to identify whether MDI power is enabled on the given port associated with the local system." REFERENCE "IEEE Std 802.3 30.12.2.1.7" ::= { lldpV2Xdot3LocPowerEntry 3 } lldpV2Xdot3LocPowerPairControlable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "The truth value is derived from the value of pethPsePortPowerPairsControlAbility object (defined in Clause 8) and is used to indicate whether the pair selection can be controlled on the given port associated with the local system." REFERENCE "IEEE Std 802.3 30.12.2.1.8" ::= { lldpV2Xdot3LocPowerEntry 4 } lldpV2Xdot3LocPowerPairs OBJECT-TYPE SYNTAX Unsigned32(1|2) MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the value of the pethPsePortPowerPairs object (defined in Clause 8) which is associated with the given port on the local system." REFERENCE "IEEE Std 802.3 30.12.2.1.9" ::= { lldpV2Xdot3LocPowerEntry 5 } lldpV2Xdot3LocPowerClass OBJECT-TYPE SYNTAX Unsigned32(1|2|3|4|5) MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the value of the pethPsePortPowerClassifications object (defined in Clause 8) which is associated with the given port on the local system." REFERENCE "IEEE Std 802.3 30.12.2.1.10" ::= { lldpV2Xdot3LocPowerEntry 6 } lldpV2Xdot3LocPowerType OBJECT-TYPE SYNTAX INTEGER { psetype1(0), psetype2(1), pdtype(2), pdtype2(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "A GET returns an integer indicating whether the local system is a PSE or a PD and whether it is Type 1 or Type 2." REFERENCE "IEEE Std 802.3 30.12.2.1.14" ::= { lldpV2Xdot3LocPowerEntry 7 } lldpV2Xdot3LocPowerSource OBJECT-TYPE SYNTAX INTEGER { pseprimary(0), psebackup(1), pseunknown(2), pdpseandlocal(3), pdpseonly(4), pdunknown(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "A GET returns an integer indicating the power sources of the local system. A PSE indicates whether it is being powered by a primary power source; a backup power source; or unknown. A PD indicates whether it is being powered by a PSE and locally; by a PSE only; or unknown." REFERENCE "IEEE Std 802.3 30.12.2.1.15" ::= { lldpV2Xdot3LocPowerEntry 8 } lldpV2Xdot3LocPowerPriority OBJECT-TYPE SYNTAX INTEGER { low(0), high(1), critical(2), unknown(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "A GET returns the priority of a PD system. For a PSE, this is the priority that the PSE assigns to the PD. For a PD, this is the priority that the PD requests from the PSE. A SET operation changes the priority of the PD system to the indicated value." REFERENCE "IEEE Std 802.3 30.12.2.1.16" ::= { lldpV2Xdot3LocPowerEntry 9 } lldpV2Xdot3LocPDRequestedPowerValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A GET returns the PD requested power value. For a PD, it is the power value that the PD has currently requested from the remote system. PD requested power value is the maximum input average power the PD ever draws under this power allocation if accepted. For a PSE, it is the power value that the PSE mirrors back to the remote system. This is the PD requested power value that was used by the PSE to compute the power it has currently allocated to the remote system. The PD requested power value is encoded according to IEEE Std 802.3 Equation (79?1), where X is the decimal value of aLldpXdot3LocPDRequestedPowerValue." REFERENCE "IEEE Std 802.3 30.12.2.1.17" ::= { lldpV2Xdot3LocPowerEntry 10 } lldpV2Xdot3LocPSEAllocatedPowerValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A GET returns the PSE allocated power value. For a PSE, it is the power value that the PSE has currently allocated to the remote system. The PSE allocated power value is the maximum input average power that the PSE wants the PD to ever draw under this allocation if it is accepted. For a PD, it is the power value that the PD mirrors back to the remote system. This is the PSE allocated power value that was used by the PD to compute the power that it has currently requested from the remote system. The PSE allocated power value is encoded according to IEEE Std 802.3 Equation (79?2), where X is the decimal value of aLldpXdot3LocPSEAllocatedPowerValue." REFERENCE "IEEE Std 802.3 30.12.2.1.18" ::= { lldpV2Xdot3LocPowerEntry 11 } lldpV2Xdot3LocResponseTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A GET returns the response time in seconds of the local system. For a PD, it is the maximum time required to update the value of lldpV2Xdot3LocPDRequestedPowerValue when the remote system requests the PD to change its max power draw. For a PSE, it is the maximum time required to update the value of lldpV2Xdot3LocPDRequestedPowerValue when the remote system requests of the PSE a new power value." REFERENCE "IEEE Std 802.3 30.12.2.1.19" ::= { lldpV2Xdot3LocPowerEntry 12 } lldpV2Xdot3LocReady OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "The truth value used to identify whether the local Data Link Layer classification engine has completed initialization and is ready to receive and transmit LLDPDUs." REFERENCE "IEEE Std 802.3 30.12.2.1.20" ::= { lldpV2Xdot3LocPowerEntry 13 } lldpV2Xdot3LocReducedOperationPowerValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A GET returns the reduced operation power value. For a PD, it is a power value that is lower than the currently requested power value. This reduced operation power value represents a power state in which the PD could continue to operate, but with less functionality than at the current PD requested power value. The PSE could optionally use this information in the event that the PSE subsequently requests a lower PD power value than the PD requested power value. For a PSE, it is a power value that the PSE could ask the PD to move to if the PSE wants the PD to move to a lower power state. The definition and encoding of PD requested power value is the same as described in lldpV2Xdot3LocPDRequestedPowerValue. The default value for this field is the hexadecimal value FFFF" REFERENCE "IEEE Std 802.3 30.12.2.1.21" ::= { lldpV2Xdot3LocPowerEntry 14 } --- --- --- lldpV2Xdot3LocMaxFrameSizeTable: Maximum Frame Size information --- V2 modified to be indexed by ifIndex. --- --- lldpV2Xdot3LocMaxFrameSizeTable OBJECT-TYPE SYNTAX SEQUENCE OF LldpV2Xdot3LocMaxFrameSizeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains one row per port of maximum frame size information (as a part of the LLDP IEEE 802.3 organizational extension) on the local system known to this agent." ::= { lldpV2Xdot3LocalData 3 } lldpV2Xdot3LocMaxFrameSizeEntry OBJECT-TYPE SYNTAX LldpV2Xdot3LocMaxFrameSizeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maximum Frame Size information about a particular port component." INDEX { lldpV2LocPortIfIndex } ::= { lldpV2Xdot3LocMaxFrameSizeTable 1 } LldpV2Xdot3LocMaxFrameSizeEntry ::= SEQUENCE { lldpV2Xdot3LocMaxFrameSize Unsigned32 } lldpV2Xdot3LocMaxFrameSize OBJECT-TYPE SYNTAX Unsigned32(0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "An integer value indicating the maximum supported frame size in octets on the given port of the local system." REFERENCE "IEEE Std 802.3 30.12.2.1.13" ::= { lldpV2Xdot3LocMaxFrameSizeEntry 1 } --- --- --- lldpV2Xdot3LocEEETable: Energy Efficient Ethernet Information Table --- V2 modified to be indexed by ifIndex. --- --- lldpV2Xdot3LocEEETable OBJECT-TYPE SYNTAX SEQUENCE OF LldpV2Xdot3LocEEEEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains one row per port of Energy Efficient Ethernet information (as a part of the LLDP IEEE 802.3 organizational extension) on the local system known to this agent." ::= { lldpV2Xdot3LocalData 4 } lldpV2Xdot3LocEEEEntry OBJECT-TYPE SYNTAX LldpV2Xdot3LocEEEEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a particular port component." INDEX { lldpV2LocPortIfIndex } ::= { lldpV2Xdot3LocEEETable 1 } LldpV2Xdot3LocEEEEntry ::= SEQUENCE { lldpV2Xdot3LocTxTwSys Integer32, lldpV2Xdot3LocTxTwSysEcho Integer32, lldpV2Xdot3LocRxTwSys Integer32, lldpV2Xdot3LocRxTwSysEcho Integer32, lldpV2Xdot3LocFbTwSys Integer32, lldpV2Xdot3TxDllReady TruthValue, lldpV2Xdot3RxDllReady TruthValue, lldpV2Xdot3LocDllEnabled TruthValue } lldpV2Xdot3LocTxTwSys OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A GET returns the value of Tw_sys_tx that the local system can support in the transmit direction. This object maps to the variable LocTxSystemValue as defined in IEEE Std 802.3 78.4.2.3." REFERENCE "IEEE Std 802.3 30.12.2.1.22" ::= {lldpV2Xdot3LocEEEEntry 1 } lldpV2Xdot3LocTxTwSysEcho OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A GET returns the value of Tw_sys_tx that the remote system is advertising that it can support in the transmit direction and is echoed by the local system under the control of the EEE DLL receiver state diagram. This object maps to the variable LocTxSystemValueEcho as defined in IEEE Std 802.3 78.4.2.3" REFERENCE "IEEE Std 802.3 30.12.2.1.23" ::= {lldpV2Xdot3LocEEEEntry 2 } lldpV2Xdot3LocRxTwSys OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A GET returns the value of Tw_sys_tx that the local system is requesting in the receive direction. This object maps to the variable LocRxSystemValue as defined in IEEE Std 802.3 78.4.2.3." REFERENCE "IEEE Std 802.3 30.12.2.1.24" ::= {lldpV2Xdot3LocEEEEntry 3 } lldpV2Xdot3LocRxTwSysEcho OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A GET returns the value of Tw_sys_tx that the remote system is advertising that it is requesting in the receive direction and is echoed by the local system under the control of the EEE DLL transmitter state diagram. This object maps to the variable LocRxSystemValueEcho as defined in IEEE Std 802.3 78.4.2.3." REFERENCE "IEEE Std 802.3 30.12.2.1.25" ::= {lldpV2Xdot3LocEEEEntry 4 } lldpV2Xdot3LocFbTwSys OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A GET returns the value of the fallback Tw_sys_tx that the local system is advertising to the remote system. This object maps to the variable LocFbSystemValue as defined in IEEE Std 802.3 78.4.2.3." REFERENCE "IEEE Std 802.3 30.12.2.1.26" ::= {lldpV2Xdot3LocEEEEntry 5 } lldpV2Xdot3TxDllReady OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "The truth value used to identify whether the local Data Link Layer EEE layer management function has completed initialization and is ready to receive and transmit LLDPDUs." REFERENCE "IEEE Std 802.3 30.12.2.1.27" ::= {lldpV2Xdot3LocEEEEntry 6 } lldpV2Xdot3RxDllReady OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "The truth value used to identify whether the local Data Link Layer EEE layer management function has completed initialization and is ready to receive and transmit LLDPDUs." REFERENCE "IEEE Std 802.3 30.12.2.1.28" ::= {lldpV2Xdot3LocEEEEntry 7 } lldpV2Xdot3LocDllEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "The truth value used to identify whether the local system has completed auto-negotiation with a link partner that has indicated at leat one EEE capability." REFERENCE "IEEE Std 802.3 30.12.2.1.29" ::= {lldpV2Xdot3LocEEEEntry 8 } ------------------------------------------------------------------------------ -- IEEE 802.3 - Remote Devices Information ------------------------------------------------------------------------------ --- --- --- lldpV2Xdot3RemPortTable: Ethernet Information Table --- V2 modified to be indexed by ifIndex and destination MAC address. --- --- lldpV2Xdot3RemPortTable OBJECT-TYPE SYNTAX SEQUENCE OF LldpV2Xdot3RemPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains Ethernet port information (as a part of the LLDP IEEE 802.3 organizational extension) of the remote system." ::= { lldpV2Xdot3RemoteData 1 } lldpV2Xdot3RemPortEntry OBJECT-TYPE SYNTAX LldpV2Xdot3RemPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a particular physical network connection." INDEX { lldpV2RemTimeMark, lldpV2RemLocalIfIndex, lldpV2RemLocalDestMACAddress, lldpV2RemIndex } ::= { lldpV2Xdot3RemPortTable 1 } LldpV2Xdot3RemPortEntry ::= SEQUENCE { lldpV2Xdot3RemPortAutoNegSupported TruthValue, lldpV2Xdot3RemPortAutoNegEnabled TruthValue, lldpV2Xdot3RemPortAutoNegAdvertisedCap OCTET STRING, lldpV2Xdot3RemPortOperMauType Unsigned32 } lldpV2Xdot3RemPortAutoNegSupported OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "The truth value used to indicate whether the given port (associated with remote system) supports Auto-negotiation." REFERENCE "IEEE Std 802.3 30.12.3.1.1" ::= { lldpV2Xdot3RemPortEntry 1 } lldpV2Xdot3RemPortAutoNegEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "The truth value used to indicate whether port Auto-negotiation is enabled on the given port associated with the remote system." REFERENCE "IEEE Std 802.3 30.12.3.1.2" ::= { lldpV2Xdot3RemPortEntry 2 } lldpV2Xdot3RemPortAutoNegAdvertisedCap OBJECT-TYPE SYNTAX OCTET STRING(SIZE(2)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the value (bitmap) of the ifMauAutoNegCapAdvertisedBits object (defined in IETF RFC 3636) which is associated with the given port on the remote system." REFERENCE "IEEE Std 802.3 30.12.3.1.3" ::= { lldpV2Xdot3RemPortEntry 3 } lldpV2Xdot3RemPortOperMauType OBJECT-TYPE SYNTAX Unsigned32(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "An integer value that indicates the operational MAU type of the sending device. This object contains the integer value derived from the list position of the corresponding dot3MauType as listed in in Clause 13 and is equal to the last number in the respective dot3MauType OID. For example, if the ifMauType object is dot3MauType1000BaseTHD which corresponds to {dot3MauType 29}, the numerical value of this field is 29. For MAU types not listed in Clause 13, the value of this field shall be set to zero." REFERENCE "IEEE Std 802.3 30.12.3.1.4" ::= { lldpV2Xdot3RemPortEntry 4 } --- --- --- lldpV2Xdot3RemPowerTable: Power Ethernet Information Table --- V2 modified to be indexed by ifIndex and destination MAC address. --- --- lldpV2Xdot3RemPowerTable OBJECT-TYPE SYNTAX SEQUENCE OF LldpV2Xdot3RemPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains Ethernet power information (as a part of the LLDP IEEE 802.3 organizational extension) of the remote system." ::= { lldpV2Xdot3RemoteData 2 } lldpV2Xdot3RemPowerEntry OBJECT-TYPE SYNTAX LldpV2Xdot3RemPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a particular physical network connection." INDEX { lldpV2RemTimeMark, lldpV2RemLocalIfIndex, lldpV2RemLocalDestMACAddress, lldpV2RemIndex } ::= { lldpV2Xdot3RemPowerTable 1 } LldpV2Xdot3RemPowerEntry ::= SEQUENCE { lldpV2Xdot3RemPowerPortClass LldpV2PowerPortClass, lldpV2Xdot3RemPowerMDISupported TruthValue, lldpV2Xdot3RemPowerMDIEnabled TruthValue, lldpV2Xdot3RemPowerPairControlable TruthValue, lldpV2Xdot3RemPowerPairs Unsigned32, lldpV2Xdot3RemPowerClass Unsigned32, lldpV2Xdot3RemPowerType INTEGER, lldpV2Xdot3RemPowerSource INTEGER, lldpV2Xdot3RemPowerPriority INTEGER, lldpV2Xdot3RemPDRequestedPowerValue Integer32, lldpV2Xdot3RemPSEAllocatedPowerValue Integer32 } lldpV2Xdot3RemPowerPortClass OBJECT-TYPE SYNTAX LldpV2PowerPortClass MAX-ACCESS read-only STATUS current DESCRIPTION "The value that identifies the port Class of the given port associated with the remote system." REFERENCE "IEEE Std 802.3 30.12.3.1.5" ::= { lldpV2Xdot3RemPowerEntry 1 } lldpV2Xdot3RemPowerMDISupported OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "The truth value used to indicate whether the MDI power is supported on the given port associated with the remote system." REFERENCE "IEEE Std 802.3 30.12.3.1.6" ::= { lldpV2Xdot3RemPowerEntry 2 } lldpV2Xdot3RemPowerMDIEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "The truth value used to identify whether MDI power is enabled on the given port associated with the remote system." REFERENCE "IEEE Std 802.3 30.12.3.1.7" ::= { lldpV2Xdot3RemPowerEntry 3 } lldpV2Xdot3RemPowerPairControlable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "The truth value is derived from the value of pethPsePortPowerPairsControlAbility object (defined in Clause 8) and is used to indicate whether the pair selection can be controlled on the given port associated with the remote system." REFERENCE "IEEE Std 802.3 30.12.3.1.8" ::= { lldpV2Xdot3RemPowerEntry 4 } lldpV2Xdot3RemPowerPairs OBJECT-TYPE SYNTAX Unsigned32(1|2) MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the value of the pethPsePortPowerPairs object (defined in Clause 8) which is associated with the given port on the remote system." REFERENCE "IEEE Std 802.3 30.12.3.1.9" ::= { lldpV2Xdot3RemPowerEntry 5 } lldpV2Xdot3RemPowerClass OBJECT-TYPE SYNTAX Unsigned32(1|2|3|4|5) MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the value of the pethPsePortPowerClassifications object (defined in Clause 8) which is associated with the given port on the remote system." REFERENCE "IEEE Std 802.3 30.12.3.1.10" ::= { lldpV2Xdot3RemPowerEntry 6 } lldpV2Xdot3RemPowerType OBJECT-TYPE SYNTAX INTEGER { psetype1(0), psetype2(1), pdtype(2), pdtype2(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "A GET returns an integer indicating whether the remote system is a PSE or a PD and whether it is Type 1 or Type 2." REFERENCE "IEEE Std 802.3 30.12.3.1.14" ::= { lldpV2Xdot3RemPowerEntry 7 } lldpV2Xdot3RemPowerSource OBJECT-TYPE SYNTAX INTEGER { pseprimary(0), psebackup(1), pseunknown(2), pdpseandlocal(3), pdlocalonly(4), pdpseonly(5), pdunknown(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "A GET returns an integer indicating the power sources of the remote system. When the remote system is a PSE, it indicates whether it is being powered by a primary power source; a backup power source; or unknown. When the remote system is a PD, it indicates whether it is being powered by a PSE and locally; locally only; by a PSE only; or unknown." REFERENCE "IEEE Std 802.3 30.12.3.1.15" ::= { lldpV2Xdot3RemPowerEntry 8 } lldpV2Xdot3RemPowerPriority OBJECT-TYPE SYNTAX INTEGER { low(0), high(1), critical(2), unknown(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "A GET returns the priority of a PD system. For a PSE, this is the priority that the remote system requests. For a PD, this is the priority that the remote system has assigned." REFERENCE "IEEE Std 802.3 30.12.3.1.16" ::= { lldpV2Xdot3RemPowerEntry 9 } lldpV2Xdot3RemPDRequestedPowerValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A GET returns the PD requested power value that was used by the remote system to compute the power value that is has currently allocated to the PD. For a PSE, it is the PD requested power value received from the remote system. The definition and encoding of PD requested power value is the same as described in lldpV2Xdot3LocPDRequestedPowerValue." REFERENCE "IEEE Std 802.3 30.12.3.1.17" ::= { lldpV2Xdot3RemPowerEntry 10 } lldpV2Xdot3RemPSEAllocatedPowerValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A GET returns the PSE allocated power value received from the remote system. For a PSE, it is the PSE allocated power value that was used by the remote system to compute the power value that it has currently requested from the PSE. For a PD, it is the PSE allocated power value received from the remote system. The definition and encoding of PSE allocated power value is the same as described in lldpV2Xdot3LocPSEAllocatedPowerValue." REFERENCE "IEEE Std 802.3 30.12.3.1.18" ::= { lldpV2Xdot3RemPowerEntry 11 } --- --- lldpV2Xdot3RemMaxFrameSizeTable: Maximum Frame Size information --- V2 modified to be indexed by ifIndex and destination MAC address. --- --- lldpV2Xdot3RemMaxFrameSizeTable OBJECT-TYPE SYNTAX SEQUENCE OF LldpV2Xdot3RemMaxFrameSizeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains one row per port/destination address pair of maximum frame size information (as a part of the LLDP IEEE 802.3 organizational extension) of the remote system." ::= { lldpV2Xdot3RemoteData 3 } lldpV2Xdot3RemMaxFrameSizeEntry OBJECT-TYPE SYNTAX LldpV2Xdot3RemMaxFrameSizeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maximum Frame Size information about a particular port component." INDEX { lldpV2RemTimeMark, lldpV2RemLocalIfIndex, lldpV2RemLocalDestMACAddress, lldpV2RemIndex } ::= { lldpV2Xdot3RemMaxFrameSizeTable 1 } LldpV2Xdot3RemMaxFrameSizeEntry ::= SEQUENCE { lldpV2Xdot3RemMaxFrameSize Unsigned32 } lldpV2Xdot3RemMaxFrameSize OBJECT-TYPE SYNTAX Unsigned32(0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "An integer value indicating the maximum supported frame size in octets on the port component associated with the remote system." REFERENCE "IEEE Std 802.3 30.12.3.1.13" ::= { lldpV2Xdot3RemMaxFrameSizeEntry 1 } --- --- --- lldpV2Xdot3RemEEETable: Energy Efficient Ethernet Information Table --- V2 modified to be indexed by ifIndex. --- --- lldpV2Xdot3RemEEETable OBJECT-TYPE SYNTAX SEQUENCE OF LldpV2Xdot3RemEEEEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains one row per port of Energy Efficient Ethernet information (as a part of the LLDP IEEE 802.3 organizational extension) on the local system known to this agent." ::= { lldpV2Xdot3RemoteData 4 } lldpV2Xdot3RemEEEEntry OBJECT-TYPE SYNTAX LldpV2Xdot3RemEEEEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a particular port component." INDEX { lldpV2RemLocalIfIndex } ::= { lldpV2Xdot3RemEEETable 1 } LldpV2Xdot3RemEEEEntry ::= SEQUENCE { lldpV2Xdot3RemTxTwSys Integer32, lldpV2Xdot3RemTxTwSysEcho Integer32, lldpV2Xdot3RemRxTwSys Integer32, lldpV2Xdot3RemRxTwSysEcho Integer32, lldpV2Xdot3RemFbTwSys Integer32 } lldpV2Xdot3RemTxTwSys OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A GET returns the value of Tw_sys_tx that the remote system can support in the transmit direction. This object maps to the variable RemTxSystemValue as defined in IEEE Std 802.3 78.4.2.3." REFERENCE "IEEE Std 802.3 30.12.3.1.19" ::= {lldpV2Xdot3RemEEEEntry 1 } lldpV2Xdot3RemTxTwSysEcho OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A GET returns the value of Tw_sys_tx that the local system is advertising that it can support in the transmit direction as echoed by the remote system under the control of the EEE DLL receiver state diagram. This object maps to the variable RemTxSystemValueEcho as defined in IEEE Std 802.3 78.4.2.3" REFERENCE "IEEE Std 802.3 30.12.3.1.20" ::= {lldpV2Xdot3RemEEEEntry 2 } lldpV2Xdot3RemRxTwSys OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A GET returns the value of Tw_sys_tx that the remote system is requesting in the receive direction. This object maps to the variable RemRxSystemValue as defined in IEEE Std 802.3 78.4.2.3." REFERENCE "IEEE Std 802.3 30.12.3.1.21" ::= {lldpV2Xdot3RemEEEEntry 3 } lldpV2Xdot3RemRxTwSysEcho OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A GET returns the value of Tw_sys_tx that the local system is advertising that it is requesting in the receive direction and is echoed by the remote system under the control of the EEE DLL transmitter state diagram. This object maps to the variable RemRxSystemValueEcho as defined in IEEE Std 802.3 78.4.2.3." REFERENCE "IEEE Std 802.3 30.12.3.1.22" ::= {lldpV2Xdot3RemEEEEntry 4 } lldpV2Xdot3RemFbTwSys OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A GET returns the value of the fallback Tw_sys_tx that the remote system is advertising. This object maps to the variable RemFbSystemValue as defined in IEEE Std 802.3 78.4.2.3." REFERENCE "IEEE Std 802.3 30.12.3.1.23" ::= {lldpV2Xdot3RemEEEEntry 5 } ------------------------------------------------------------------------------ -- Conformance statements ------------------------------------------------------------------------------ lldpV2Xdot3Conformance OBJECT IDENTIFIER ::= { ieee8023lldpV2Xdot3MIB 2 } lldpV2Xdot3Compliances OBJECT IDENTIFIER ::= { lldpV2Xdot3Conformance 1 } lldpV2Xdot3Groups OBJECT IDENTIFIER ::= { lldpV2Xdot3Conformance 2 } -- Compliance statements lldpV2Xdot3TxRxCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "A compliance statement for SNMP entities that implement the LLDP IEEE 802.3 organizational extension MIB. This group is mandatory for all agents that implement the LLDP IEEE 802.3 organizational extension in TX and/or RX mode. This version defines compliance requirements for V2 of the LLDP MIB." MODULE -- this module MANDATORY-GROUPS { lldpV2Xdot3ConfigGroup, ifGeneralInformationGroup } ::= { lldpV2Xdot3Compliances 1 } lldpV2Xdot3TxCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for SNMP entities that implement the LLDP IEEE 802.3 organizational extension MIB. This group is mandatory for agents that implement the LLDP IEEE 802.3 organizational extension in the TX mode. This version defines compliance requirements for V2 of the LLDP MIB." MODULE -- this module MANDATORY-GROUPS { lldpV2Xdot3LocSysGroup } ::= { lldpV2Xdot3Compliances 2 } lldpV2Xdot3RxCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for SNMP entities that implement the LLDP IEEE 802.3 organizational extension MIB. This group is mandatory for agents that implement the LLDP IEEE 802.3 organizational extension in the RX mode. This version defines compliance requirements for V2 of the LLDP MIB." MODULE -- this module MANDATORY-GROUPS { lldpV2Xdot3RemSysGroup } ::= { lldpV2Xdot3Compliances 3 } -- MIB groupings lldpV2Xdot3ConfigGroup OBJECT-GROUP OBJECTS { lldpV2Xdot3PortConfigTLVsTxEnable } STATUS current DESCRIPTION "The collection of objects that are used to configure the LLDP IEEE 802.3 organizational extension implementation behavior." ::= { lldpV2Xdot3Groups 1 } lldpV2Xdot3LocSysGroup OBJECT-GROUP OBJECTS { lldpV2Xdot3LocPortAutoNegSupported, lldpV2Xdot3LocPortAutoNegEnabled, lldpV2Xdot3LocPortAutoNegAdvertisedCap, lldpV2Xdot3LocPortOperMauType, lldpV2Xdot3LocPowerPortClass, lldpV2Xdot3LocPowerMDISupported, lldpV2Xdot3LocPowerMDIEnabled, lldpV2Xdot3LocPowerPairControlable, lldpV2Xdot3LocPowerPairs, lldpV2Xdot3LocPowerClass, lldpV2Xdot3LocMaxFrameSize, lldpV2Xdot3LocPowerType, lldpV2Xdot3LocPowerSource, lldpV2Xdot3LocPowerPriority, lldpV2Xdot3LocPDRequestedPowerValue, lldpV2Xdot3LocPSEAllocatedPowerValue, lldpV2Xdot3LocResponseTime, lldpV2Xdot3LocReady, lldpV2Xdot3LocReducedOperationPowerValue, lldpV2Xdot3LocTxTwSys, lldpV2Xdot3LocTxTwSysEcho, lldpV2Xdot3LocRxTwSys, lldpV2Xdot3LocRxTwSysEcho, lldpV2Xdot3LocFbTwSys, lldpV2Xdot3TxDllReady, lldpV2Xdot3RxDllReady, lldpV2Xdot3LocDllEnabled } STATUS current DESCRIPTION "The collection of objects that are used to represent LLDP IEEE 802.3 organizational extension Local Device Information." ::= { lldpV2Xdot3Groups 2 } lldpV2Xdot3RemSysGroup OBJECT-GROUP OBJECTS { lldpV2Xdot3RemPortAutoNegSupported, lldpV2Xdot3RemPortAutoNegEnabled, lldpV2Xdot3RemPortAutoNegAdvertisedCap, lldpV2Xdot3RemPortOperMauType, lldpV2Xdot3RemPowerPortClass, lldpV2Xdot3RemPowerMDISupported, lldpV2Xdot3RemPowerMDIEnabled, lldpV2Xdot3RemPowerPairControlable, lldpV2Xdot3RemPowerPairs, lldpV2Xdot3RemPowerClass, lldpV2Xdot3RemMaxFrameSize, lldpV2Xdot3RemPowerType, lldpV2Xdot3RemPowerSource, lldpV2Xdot3RemPowerPriority, lldpV2Xdot3RemPDRequestedPowerValue, lldpV2Xdot3RemPSEAllocatedPowerValue, lldpV2Xdot3RemTxTwSys, lldpV2Xdot3RemTxTwSysEcho, lldpV2Xdot3RemRxTwSys, lldpV2Xdot3RemRxTwSysEcho, lldpV2Xdot3RemFbTwSys } STATUS current DESCRIPTION "The collection of objects that are used to represent LLDP IEEE 802.3 organizational extension Local Device Information." ::= { lldpV2Xdot3Groups 3 } END