IEEE8023-DOT3-EPON-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Counter32, Integer32, Unsigned32, Counter64, org FROM SNMPv2-SMI TruthValue, MacAddress FROM SNMPv2-TC ifIndex FROM IF-MIB MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF ; ieee8023dot3EponMIB MODULE-IDENTITY LAST-UPDATED "201304110000Z" -- April 11, 2013 ORGANIZATION "IEEE 802.3 working group" CONTACT-INFO "WG-URL: http://www.ieee802.org/3/index.html WG-EMail: STDS-802-3-MIB@LISTSERV.IEEE.ORG Contact: Howard Frazier Postal: 3151 Zanker Road San Jose, CA 95134 USA Tel: +1.408.922.8164 E-mail: hfrazier@broadcom.com" DESCRIPTION "The objects in this MIB module are used to manage the Ethernet in the First Mile (EFM) Ethernet Passive Optical Network (EPON) Interfaces as defined in IEEE Std 802.3 Clauses 60, 64, and 65. Of particular interest are Clause 64 (MultiPoint Control Protocol - MPCP), Clause 65 (Point-to-Multipoint Reconciliation Sublayer - P2MP RS), Clause 60 (Ethernet Passive Optical Network Physical Medium Dependent - EPON PMDs), Clause 30, 'Management', and Clause 45, 'Management Data Input/Output (MDIO) Interface'." REVISION "201304110000Z" -- April 11, 2013 DESCRIPTION "Revision, based on an earlier version in IEEE Std 802.3.1-2011." REVISION "201102020000Z" -- February 2, 2011 DESCRIPTION "Initial version, based on an earlier version published as RFC 4837." ::= { org ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot3(3) ieee802dot3dot1mibs(1) 9 } dot3EponObjects OBJECT IDENTIFIER ::= { ieee8023dot3EponMIB 1} dot3EponConformance OBJECT IDENTIFIER ::= { ieee8023dot3EponMIB 2} -- MPCP MIB modules definitions (IEEE Std 802.3, Clause 30.3.5) dot3EponMpcpObjects OBJECT IDENTIFIER ::= { dot3EponObjects 1 } dot3MpcpControlTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot3MpcpControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A Table of dot3 MultiPoint Control Protocol (MPCP) MIB objects. The entries in the table are control and status objects of the MPCP. Each object has a row for every virtual link denoted by the corresponding ifIndex. The LLID field, as defined in the IEEE Std 802.3, is a 2-byte register (15-bit field and a broadcast bit) limiting the number of virtual links to 32768. Typically the number of expected virtual links in a PON is like the number of ONUs, which is 32-64, plus an additional entry for broadcast LLID." ::= { dot3EponMpcpObjects 1 } dot3MpcpControlEntry OBJECT-TYPE SYNTAX Dot3MpcpControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot3 MPCP Control table. Rows exist for an OLT interface and an ONU interface. A row in the table is denoted by the ifIndex of the link and it is created when the ifIndex is created. The rows in the table for an ONU interface are created at system initialization. The row in the table corresponding to the OLT ifIndex and the row corresponding to the broadcast virtual link are created at system initialization. A row in the table corresponding to the ifIndex of a virtual links is created when a virtual link is established (ONU registers) and deleted when the virtual link is deleted (ONU deregisters)." INDEX { ifIndex } ::= { dot3MpcpControlTable 1} Dot3MpcpControlEntry ::= SEQUENCE { dot3MpcpOperStatus TruthValue, dot3MpcpAdminState TruthValue, dot3MpcpMode INTEGER, dot3MpcpSyncTime Unsigned32, dot3MpcpLinkID Unsigned32, dot3MpcpRemoteMACAddress MacAddress, dot3MpcpRegistrationState INTEGER, dot3MpcpTransmitElapsed Unsigned32, dot3MpcpReceiveElapsed Unsigned32, dot3MpcpRoundTripTime Unsigned32, dot3MpcpMaximumPendingGrants Unsigned32 } dot3MpcpOperStatus OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the operational state of the MultiPoint MAC Control sublayer as defined in IEEE Std 802.3, Clause 64 and Clause 77. When the value is true(1), the interface will act as if the MultiPoint Control Protocol is enabled. When the value is false(2), the interface will act as if the MultiPoint Control Protocol is disabled. The operational state can be changed using the dot3MpcpAdminState object. This object is applicable for an OLT, with the same value for all virtual interfaces, and for an ONU." REFERENCE "IEEE Std 802.3, 30.3.5.1.2." ::= { dot3MpcpControlEntry 1 } dot3MpcpAdminState OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to define the admin state of the MultiPoint MAC Control sublayer, as defined in IEEE Std 802.3, Clause 64, and to reflect its state. When selecting the value as true(1), the MultiPoint Control Protocol of the interface is enabled. When selecting the value as false(2), the MultiPoint Control Protocol of the interface is disabled. This object reflects the administrative state of the MultiPoint Control Protocol of the interface. The write operation is not restricted in this document and can be done at any time. Changing dot3MpcpAdminState state can lead to disabling the MultiPoint Control Protocol on the respective interface, leading to the interruption of service for the users connected to the respective EPON interface. This object is applicable for an OLT, with the same value for all virtual interfaces, and for an ONU." REFERENCE "IEEE Std 802.3, 30.3.5.2.1." DEFVAL { false } ::= { dot3MpcpControlEntry 2 } dot3MpcpMode OBJECT-TYPE SYNTAX INTEGER { olt(1), onu(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to identify the operational state of the MultiPoint MAC Control sublayer as defined in IEEE Std 802.3, Clause 64 and Clause 77. Reading olt(1) for an OLT (server) mode and onu(2) for an ONU (client) mode. This object is used to identify the operational mode for the MPCP tables. This object is applicable for an OLT, with the same value for all virtual interfaces, and for an ONU." REFERENCE "IEEE Std 802.3, 30.3.5.1.3." DEFVAL { olt } ::= { dot3MpcpControlEntry 3 } dot3MpcpSyncTime OBJECT-TYPE SYNTAX Unsigned32 UNITS "TQ (16 ns)" MAX-ACCESS read-only STATUS current DESCRIPTION "An object that reports the 'sync lock time' of the OLT receiver in increments of Time Quanta (TQ)-16ns as defined in IEEE Std 802.3, Clauses 60, 64, and 65. The value returned shall be (sync lock time ns)/16, rounded up to the nearest TQ. If this value exceeds (2^32-1), the value (2^32-1) shall be returned. This object is applicable for an OLT, with distinct values for all virtual interfaces, and for an ONU." REFERENCE "IEEE Std 802.3, 64.3.3.2." ::= { dot3MpcpControlEntry 4 } dot3MpcpLinkID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "An object that identifies the Logical Link Identifier (LLID) associated with the MAC of the virtual link as specified in IEEE Std 802.3, 65.1.3.2.2 or 76.2.6.1.3.2, as appropriate. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. The ONU and the corresponding virtual MAC of the OLT, for the same virtual link, have the same value. Value is assigned when the ONU registers. Value is freed when the ONU deregisters." REFERENCE "IEEE Std 802.3, 30.3.5.1.4." ::= { dot3MpcpControlEntry 5 } dot3MpcpRemoteMACAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "An object that identifies the source_address parameter of the last MPCPDUs passed to the MAC Control. This value is updated on reception of a valid frame with 1) a destination Field equal to the reserved multicast address for MAC Control as specified in IEEE Std 802.3, Annex 31A; 2) the lengthOrType field value equal to the reserved Type for MAC Control as specified in IEEE Std 802.3, Annex 31A; 3) an MPCP subtype value equal to the subtype reserved for MPCP as specified in IEEE Std 802.3, Annex 31A. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. The value reflects the MAC address of the remote entity and therefore the OLT holds a value for each LLID, which is the MAC address of the ONU; the ONU has a single value that is the OLT MAC address." REFERENCE "IEEE Std 802.3, 30.3.5.1.5." ::= { dot3MpcpControlEntry 6 } dot3MpcpRegistrationState OBJECT-TYPE SYNTAX INTEGER { unregistered(1), registering(2), registered(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "An object that identifies the registration state of the MultiPoint MAC Control sublayer as defined in IEEE Std 802.3, Clause 64. When this object has the enumeration unregistered(1), the interface is unregistered and may be used for registering a link partner. When this object has the enumeration registering(2), the interface is in the process of registering a link-partner. When this object has the enumeration registered(3), the interface has an established link-partner. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface." REFERENCE "IEEE Std 802.3, 30.3.5.1.6." ::= { dot3MpcpControlEntry 7 } dot3MpcpTransmitElapsed OBJECT-TYPE SYNTAX Unsigned32 UNITS "TQ (16 ns)" MAX-ACCESS read-only STATUS current DESCRIPTION "An object that reports the interval from the last MPCP frame transmission in increments of Time Quanta (TQ)-16ns. The value returned shall be (interval from last MPCP frame transmission in ns)/16. If this value exceeds (2^32-1), the value (2^32-1) shall be returned. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface." REFERENCE "IEEE Std 802.3, 30.3.5.1.19." ::= { dot3MpcpControlEntry 8 } dot3MpcpReceiveElapsed OBJECT-TYPE SYNTAX Unsigned32 UNITS "TQ (16 ns)" MAX-ACCESS read-only STATUS current DESCRIPTION "An object that reports the interval from last MPCP frame reception in increments of Time Quanta (TQ)-16ns. The value returned shall be (interval from last MPCP frame reception in ns)/16. If this value exceeds (2^32-1), the value (2^32-1) shall be returned. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface." REFERENCE "IEEE Std 802.3, 30.3.5.1.20." ::= { dot3MpcpControlEntry 9 } dot3MpcpRoundTripTime OBJECT-TYPE SYNTAX Unsigned32 (0..'ffff'h) UNITS "TQ (16 ns)" MAX-ACCESS read-only STATUS current DESCRIPTION "An object that reports the MPCP round trip time in increments of Time Quanta (TQ)-16ns. The value returned shall be (round trip time in ns)/16. If this value exceeds (2^16-1), the value (2^16-1) shall be returned. This object is applicable for an OLT. At the OLT, it has a distinct value for each virtual interface." REFERENCE "IEEE Std 802.3, 30.3.5.1.21." ::= { dot3MpcpControlEntry 10 } dot3MpcpMaximumPendingGrants OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "An object that reports the maximum number of grants that an ONU can store for handling. The maximum number of grants that an ONU can store for handling has a range of 0 to 255. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. At the OLT, the value should be zero." REFERENCE "IEEE Std 802.3, 30.3.5.1.24." ::= { dot3MpcpControlEntry 11 } dot3MpcpStatTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot3MpcpStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table defines the list of statistics counters of an interface implementing the IEEE Std 802.3, Clause 64 MPCP. Each object has a row for every virtual link denoted by the corresponding ifIndex. The LLID field, as defined in IEEE Std 802.3, is a 2-byte register (15-bit field and a broadcast bit) limiting the number of virtual links to 32768. Typically the number of expected virtual links in a PON is like the number of ONUs, which is 32-64, plus an additional entry for broadcast LLID." ::= { dot3EponMpcpObjects 2 } dot3MpcpStatEntry OBJECT-TYPE SYNTAX Dot3MpcpStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table of statistics counters of the IEEE Std 802.3, Clause 64, MPCP interface. Rows exist for an OLT interface and an ONU interface. A row in the table is denoted by the ifIndex of the link and it is created when the ifIndex is created. The rows in the table for an ONU interface are created at system initialization. The row in the table corresponding to the OLT ifIndex and the row corresponding to the broadcast virtual link are created at system initialization. A row in the table corresponding to the ifIndex of a virtual link is created when a virtual link is established (ONU registers) and deleted when the virtual link is deleted (ONU deregisters)." INDEX { ifIndex} ::= { dot3MpcpStatTable 1 } Dot3MpcpStatEntry ::= SEQUENCE { dot3MpcpMACCtrlFramesTransmitted Counter64, dot3MpcpMACCtrlFramesReceived Counter64, dot3MpcpDiscoveryWindowsSent Counter32, dot3MpcpDiscoveryTimeout Counter32, dot3MpcpTxRegRequest Counter64, dot3MpcpRxRegRequest Counter64, dot3MpcpTxRegAck Counter64, dot3MpcpRxRegAck Counter64, dot3MpcpTxReport Counter64, dot3MpcpRxReport Counter64, dot3MpcpTxGate Counter64, dot3MpcpRxGate Counter64, dot3MpcpTxRegister Counter64, dot3MpcpRxRegister Counter64 } dot3MpcpMACCtrlFramesTransmitted OBJECT-TYPE SYNTAX Counter64 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of MPCP frames passed to the MAC sublayer for transmission. This counter is incremented when a MA_CONTROL.request service primitive is generated within the MAC control sublayer with an opcode indicating an MPCP frame. This object is applicable for an OLT and an ONU. At the OLT it has a distinct value for each virtual interface. Discontinuities of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of the ifCounterDiscontinuityTime object of the Interfaces Group MIB module." REFERENCE "IEEE Std 802.3, 30.3.5.1.7." ::= { dot3MpcpStatEntry 1 } dot3MpcpMACCtrlFramesReceived OBJECT-TYPE SYNTAX Counter64 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of MPCP frames passed by the MAC sublayer to the MAC Control sublayer. This counter is incremented when a ReceiveFrame function call returns a valid frame with 1) a lengthOrType field value equal to the reserved Type for 802.3_MAC_Control as specified in IEEE Std 802.3 31.4.1.3, and 2) an opcode indicating an MPCP frame. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. Discontinuities of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of the ifCounterDiscontinuityTime object of the Interfaces Group MIB module." REFERENCE "IEEE Std 802.3, 30.3.5.1.8." ::= { dot3MpcpStatEntry 2} dot3MpcpDiscoveryWindowsSent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of discovery windows generated. The counter is incremented by one for each generated discovery window. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. At the ONU, the value should be zero. Discontinuities of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of the ifCounterDiscontinuityTime object of the Interfaces Group MIB module." REFERENCE "IEEE Std 802.3, 30.3.5.1.22." ::= { dot3MpcpStatEntry 3} dot3MpcpDiscoveryTimeout OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a discovery timeout occurs. Increment the counter by one for each discovery processing state-machine reset resulting from timeout waiting for message arrival. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. Discontinuities of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of the ifCounterDiscontinuityTime object of the Interfaces Group MIB module." REFERENCE "IEEE Std 802.3, 30.3.5.1.23." ::= { dot3MpcpStatEntry 4} dot3MpcpTxRegRequest OBJECT-TYPE SYNTAX Counter64 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a REGISTER_REQ MPCP frame transmission occurs. Increment the counter by one for each REGISTER_REQ MPCP frame transmitted as defined in IEEE Std 802.3, Clause 64. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. At the OLT, the value should be zero. Discontinuities of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of the ifCounterDiscontinuityTime object of the Interfaces Group MIB module." REFERENCE "IEEE Std 802.3, 30.3.5.1.12." ::= { dot3MpcpStatEntry 5} dot3MpcpRxRegRequest OBJECT-TYPE SYNTAX Counter64 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a REGISTER_REQ MPCP frame reception occurs. Increment the counter by one for each REGISTER_REQ MPCP frame received as defined in IEEE Std 802.3, Clause 64. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. At the ONU, the value should be zero. Discontinuities of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of the ifCounterDiscontinuityTime object of the Interfaces Group MIB module." REFERENCE "IEEE Std 802.3, 30.3.5.1.17." ::= { dot3MpcpStatEntry 6} dot3MpcpTxRegAck OBJECT-TYPE SYNTAX Counter64 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a REGISTER_ACK MPCP frame transmission occurs. Increment the counter by one for each REGISTER_ACK MPCP frame transmitted as defined in IEEE Std 802.3, Clause 64. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. At the OLT, the value should be zero. Discontinuities of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of the ifCounterDiscontinuityTime object of the Interfaces Group MIB module." REFERENCE "IEEE Std 802.3, 30.3.5.1.10." ::= { dot3MpcpStatEntry 7} dot3MpcpRxRegAck OBJECT-TYPE SYNTAX Counter64 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a REGISTER_ACK MPCP frame reception occurs. Increment the counter by one for each REGISTER_ACK MPCP frame received as defined in IEEE Std 802.3, Clause 64. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. At the ONU, the value should be zero. Discontinuities of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of the ifCounterDiscontinuityTime object of the Interfaces Group MIB module." REFERENCE "IEEE Std 802.3, 30.3.5.1.15." ::= { dot3MpcpStatEntry 8} dot3MpcpTxReport OBJECT-TYPE SYNTAX Counter64 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a REPORT MPCP frame transmission occurs. Increment the counter by one for each REPORT MPCP frame transmitted as defined in IEEE Std 802.3, Clause 64. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. At the OLT, the value should be zero. Discontinuities of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of the ifCounterDiscontinuityTime object of the Interfaces Group MIB module." REFERENCE "IEEE Std 802.3, 30.3.5.1.13." ::= { dot3MpcpStatEntry 9} dot3MpcpRxReport OBJECT-TYPE SYNTAX Counter64 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a REPORT MPCP frame reception occurs. Increment the counter by one for each REPORT MPCP frame received as defined in IEEE Std 802.3, Clause 64. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. At the ONU, the value should be zero. Discontinuities of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of the ifCounterDiscontinuityTime object of the Interfaces Group MIB module." REFERENCE "IEEE Std 802.3, 30.3.5.1.18." ::= { dot3MpcpStatEntry 10} dot3MpcpTxGate OBJECT-TYPE SYNTAX Counter64 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a GATE MPCP frame transmission occurs. Increment the counter by one for each GATE MPCP frame transmitted as defined in IEEE Std 802.3, Clause 64. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. At the ONU, the value should be zero. Discontinuities of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of the ifCounterDiscontinuityTime object of the Interfaces Group MIB module." REFERENCE "IEEE Std 802.3, 30.3.5.1.9." ::= { dot3MpcpStatEntry 11} dot3MpcpRxGate OBJECT-TYPE SYNTAX Counter64 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a GATE MPCP frame reception occurs. Increment the counter by one for each GATE MPCP frame received as defined in IEEE Std 802.3, Clause 64. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. At the OLT, the value should be zero. Discontinuities of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of the ifCounterDiscontinuityTime object of the Interfaces Group MIB module." REFERENCE "IEEE Std 802.3, 30.3.5.1.14." ::= { dot3MpcpStatEntry 12} dot3MpcpTxRegister OBJECT-TYPE SYNTAX Counter64 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a REGISTER MPCP frame transmission occurs. Increment the counter by one for each REGISTER MPCP frame transmitted as defined in IEEE Std 802.3, Clause 64. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. At the ONU, the value should be zero. Discontinuities of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of the ifCounterDiscontinuityTime object of the Interfaces Group MIB module." REFERENCE "IEEE Std 802.3, 30.3.5.1.11." ::= { dot3MpcpStatEntry 13} dot3MpcpRxRegister OBJECT-TYPE SYNTAX Counter64 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a REGISTER MPCP frame reception occurs. Increment the counter by one for each REGISTER MPCP frame received as defined in IEEE Std 802.3, Clause 64. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. At the OLT, the value should be zero. Discontinuities of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of the ifCounterDiscontinuityTime object of the Interfaces Group MIB module." REFERENCE "IEEE Std 802.3, 30.3.5.1.16." ::= { dot3MpcpStatEntry 14} -- Optical Multi Point Emulation (OMPEmulation) -- managed object definitions dot3OmpEmulationObjects OBJECT IDENTIFIER ::={dot3EponObjects 2} dot3OmpEmulationTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot3OmpEmulationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of dot3 OmpEmulation MIB objects. The table contain objects for the management of the OMPEmulation sublayer. Each object has a row for every virtual link denoted by the corresponding ifIndex. The LLID field, as defined in the IEEE Std 802.3, is a 2-byte register (15-bit field and a broadcast bit) limiting the number of virtual links to 32768. Typically the number of expected virtual links in a PON is like the number of ONUs, which is 32-64, plus an additional entry for broadcast LLID." ::= { dot3OmpEmulationObjects 1 } dot3OmpEmulationEntry OBJECT-TYPE SYNTAX Dot3OmpEmulationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot3 OmpEmulation table. Rows exist for an OLT interface and an ONU interface. A row in the table is denoted by the ifIndex of the link and it is created when the ifIndex is created. The rows in the table for an ONU interface are created at system initialization. The row in the table corresponding to the OLT ifIndex and the row corresponding to the broadcast virtual link are created at system initialization. A row in the table corresponding to the ifIndex of a virtual links is created when a virtual link is established (ONU registers) and deleted when the virtual link is deleted (ONU deregisters)." INDEX { ifIndex } ::= { dot3OmpEmulationTable 1 } Dot3OmpEmulationEntry ::= SEQUENCE { dot3OmpEmulationType INTEGER } dot3OmpEmulationType OBJECT-TYPE SYNTAX INTEGER { unknown(1), olt(2), onu(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "An object that indicates the mode of operation of the Reconciliation Sublayer for Point-to-Point Emulation (see IEEE Std 802.3, 65.1 or 76.2 as appropriate). unknown(1) value is assigned in initialization; true state or type is not yet known. olt(2) value is assigned when the sublayer is operating in OLT mode. onu(3) value is assigned when the sublayer is operating in ONU mode. This object is applicable for an OLT, with the same value for all virtual interfaces, and for an ONU." REFERENCE "IEEE Std 802.3, 30.3.7.1.2." ::= { dot3OmpEmulationEntry 1} dot3OmpEmulationStatTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot3OmpEmulationStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table defines the list of statistics counters of IEEE Std 802.3, Clause 65, OMPEmulation sublayer. Each object has a row for every virtual link denoted by the corresponding ifIndex. The LLID field, as defined in the IEEE Std 802.3, is a 2-byte register (15-bit field and a broadcast bit) limiting the number of virtual links to 32768. Typically the number of expected virtual links in a PON is like the number of ONUs, which is 32-64, plus an additional entry for broadcast LLID." ::= { dot3OmpEmulationObjects 2} dot3OmpEmulationStatEntry OBJECT-TYPE SYNTAX Dot3OmpEmulationStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table of statistics counters of IEEE Std 802.3, Clause 65, OMPEmulation sublayer. Rows exist for an OLT interface and an ONU interface. A row in the table is denoted by the ifIndex of the link and it is created when the ifIndex is created. The rows in the table for an ONU interface are created at system initialization. The row in the table corresponding to the OLT ifIndex and the row corresponding to the broadcast virtual link are created at system initialization. A row in the table corresponding to the ifIndex of a virtual links is created when a virtual link is established (ONU registers) and deleted when the virtual link is deleted (ONU deregisters)." INDEX { ifIndex} ::= { dot3OmpEmulationStatTable 1 } Dot3OmpEmulationStatEntry::= SEQUENCE { dot3OmpEmulationSLDErrors Counter64, dot3OmpEmulationCRC8Errors Counter64, dot3OmpEmulationBadLLID Counter64, dot3OmpEmulationGoodLLID Counter64, dot3OmpEmulationOnuPonCastLLID Counter64, dot3OmpEmulationOltPonCastLLID Counter64, dot3OmpEmulationBroadcastBitNotOnuLlid Counter64, dot3OmpEmulationOnuLLIDNotBroadcast Counter64, dot3OmpEmulationBroadcastBitPlusOnuLlid Counter64, dot3OmpEmulationNotBroadcastBitNotOnuLlid Counter64 } dot3OmpEmulationSLDErrors OBJECT-TYPE SYNTAX Counter64 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of frames received that do not contain a valid SLD field as defined in IEEE Std 802.3, 65.1.3.3.1 or 76.2.6.1.3.1, as appropriate. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface.s Discontinuities of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of the ifCounterDiscontinuityTime object of the Interfaces Group MIB module." REFERENCE "IEEE Std 802.3, 30.3.7.1.3." ::= { dot3OmpEmulationStatEntry 1} dot3OmpEmulationCRC8Errors OBJECT-TYPE SYNTAX Counter64 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of frames received that contain a valid SLD field, as defined in IEEE Std 802.3, 65.1.3.3.1 or 76.2.6.1.3.1 as appropriate, but do not pass the CRC-8 check as defined in IEEE Std 802.3, 65.1.3.3.3 or 76.2.6.1.3.3 as appropriate. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. Discontinuities of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of the ifCounterDiscontinuityTime object of the Interfaces Group MIB module." REFERENCE "IEEE Std 802.3, 30.3.7.1.4." ::= { dot3OmpEmulationStatEntry 2} dot3OmpEmulationBadLLID OBJECT-TYPE SYNTAX Counter64 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of frames received that contain a valid SLD field in an OLT, and pass the CRC-8 check, but are discarded due to the LLID check. The SLD is defined in IEEE Std 802.3, 65.1.3.3.1 or 76.2.6.1.3.1, as appropriate. The CRC-8 check is defined in IEEE Std 802.3, 65.1.3.3.3 or 76.2.6.1.3.3, as appropriate. The LLID check is defined in IEEE Std 802.3, 65.1.3.3.2 or 76.2.6.1.3.2, as appropriate. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. Discontinuities of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of the ifCounterDiscontinuityTime object of the Interfaces Group MIB module." REFERENCE "IEEE Std 802.3, 30.3.7.1.8." ::= { dot3OmpEmulationStatEntry 3} dot3OmpEmulationGoodLLID OBJECT-TYPE SYNTAX Counter64 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of frames received that contain a valid SLD field, as defined in IEEE Std 802.3, 65.1.3.3.1 or 76.2.6.1.3.1, as appropriate, and pass the CRC-8 check as defined in IEEE Std 802.3, 65.1.3.3.3 or 76.2.6.1.3.3, as appropriate. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. Discontinuities of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of the ifCounterDiscontinuityTime object of the Interfaces Group MIB module." REFERENCE "IEEE Std 802.3, 30.3.7.1.5." ::= { dot3OmpEmulationStatEntry 4} dot3OmpEmulationOnuPonCastLLID OBJECT-TYPE SYNTAX Counter64 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of frames received that: 1) contain a valid SLD field in an ONU, 2) meet the rules for frame acceptance, and 3) pass the CRC-8 check. The SLD is defined in IEEE Std 802.3, 65.1.3.3.1 or 76.2.6.1.3.1, as appropriate. The rules for LLID acceptance are defined in IEEE Std 802.3, 65.1.3.3.2 or 76.2.6.1.3.2, as appropriate. The CRC-8 check is defined in IEEE Std 802.3, 65.1.3.3.3 or 76.2.6.1.3.3, as appropriate. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. At the OLT, the value should be zero. Discontinuities of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of the ifCounterDiscontinuityTime object of the Interfaces Group MIB module." REFERENCE "IEEE Std 802.3, 30.3.7.1.6." ::= { dot3OmpEmulationStatEntry 5} dot3OmpEmulationOltPonCastLLID OBJECT-TYPE SYNTAX Counter64 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of frames received that contain a valid SLD field, as defined in IEEE Std 802.3, 65.1.3.3.1 or 76.2.6.1.3.1, as appropriate, pass the CRC-8 check, as defined in IEEE Std 802.3, 65.1.3.3.3 or 76.2.6.1.3.3, as appropriate, and meet the rules of acceptance for an OLT defined in IEEE Std 802.3, 65.1.3.3.2 or 76.2.6.1.3.2, as appropriate. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. At the ONU, the value should be zero. Discontinuities of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of the ifCounterDiscontinuityTime object of the Interfaces Group MIB module." REFERENCE "IEEE Std 802.3, 30.3.7.1.7." ::= { dot3OmpEmulationStatEntry 6} dot3OmpEmulationBroadcastBitNotOnuLlid OBJECT-TYPE SYNTAX Counter64 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of frames received that contain a valid SLD field, as defined in IEEE Std 802.3, 65.1.3.3.1, pass the CRC-8 check, as defined in IEEE Std 802.3, 65.1.3.3.3, and contain the broadcast bit in the LLID and not the ONU's LLID (frame accepted) as defined in IEEE Std 802.3, Clause 65. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. At the OLT, the value should be zero. Discontinuities of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of the ifCounterDiscontinuityTime object of the Interfaces Group MIB module." ::= { dot3OmpEmulationStatEntry 7} dot3OmpEmulationOnuLLIDNotBroadcast OBJECT-TYPE SYNTAX Counter64 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of frames received that contain a valid SLD field, as defined in IEEE Std 802.3, 65.1.3.3.1, pass the CRC-8 check, as defined in IEEE Std 802.3, 65.1.3.3.3, and contain the ONU's LLID as defined in IEEE Std 802.3, Clause 65. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. At the OLT, the value should be zero. Discontinuities of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of the ifCounterDiscontinuityTime object of the Interfaces Group MIB module." ::= { dot3OmpEmulationStatEntry 8} dot3OmpEmulationBroadcastBitPlusOnuLlid OBJECT-TYPE SYNTAX Counter64 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of frames received that contain a valid SLD field, as defined in IEEE Std 802.3, 65.1.3.3.1, pass the CRC-8 check, as defined in IEEE Std 802.3, 65.1.3.3.3, and contain the broadcast bit in the LLID and match the ONU's LLID (frame reflected) as defined in IEEE Std 802.3, Clause 65. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. At the OLT, the value should be zero. Discontinuities of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of the ifCounterDiscontinuityTime object of the Interfaces Group MIB module." ::= { dot3OmpEmulationStatEntry 9} dot3OmpEmulationNotBroadcastBitNotOnuLlid OBJECT-TYPE SYNTAX Counter64 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of frames received that contain a valid SLD field, as defined in IEEE Std 802.3, 65.1.3.3.1, pass the CRC-8 check, as defined in IEEE Std 802.3, 65.1.3.3.3, and do not contain the ONU's LLID as defined in IEEE Std 802.3, Clause 65. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. At the OLT, the value should be zero. Discontinuities of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of the ifCounterDiscontinuityTime object of the Interfaces Group MIB module." ::= { dot3OmpEmulationStatEntry 10} -- FEC managed object definitions (30.5.1) dot3EponFecObjects OBJECT IDENTIFIER ::={dot3EponObjects 3} dot3EponFecTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot3EponFecEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of dot3 EPON FEC management objects. The entries in the table are control and status objects and statistic counters for the FEC layer. Each object has a row for every virtual link denoted by the corresponding ifIndex. The LLID field, as defined in the IEEE Std 802.3, is a 2-byte register (15-bit field and a broadcast bit) limiting the number of virtual links to 32768. Typically the number of expected virtual links in a PON is like the number of ONUs, which is 32-64, plus an additional entry for broadcast LLID." ::= { dot3EponFecObjects 1 } dot3EponFecEntry OBJECT-TYPE SYNTAX Dot3EponFecEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot3 EPON FEC table. Rows exist for an OLT interface and an ONU interface. A row in the table is denoted by the ifIndex of the link and it is created when the ifIndex is created. The rows in the table for an ONU interface are created at system initialization. The row in the table corresponding to the OLT ifIndex and the row corresponding to the broadcast virtual link are created at system initialization. A row in the table corresponding to the ifIndex of a virtual links is created when a virtual link is established (ONU registers) and deleted when the virtual link is deleted (ONU deregisters)." INDEX { ifIndex} ::= { dot3EponFecTable 1 } Dot3EponFecEntry ::= SEQUENCE { dot3EponFecPCSCodingViolation Counter64, dot3EponFecAbility INTEGER, dot3EponFecMode INTEGER, dot3EponFecCorrectedBlocks Counter64, dot3EponFecUncorrectableBlocks Counter64, dot3EponFecBufferHeadCodingViolation Counter64 } dot3EponFecPCSCodingViolation OBJECT-TYPE SYNTAX Counter64 UNITS "octets" MAX-ACCESS read-only STATUS current DESCRIPTION "For a 100 Mb/s operation, it is a count of the number of times an invalid code-group is received, other than the /H/ code-group. For a 1000 Mb/s operation, it is a count of the number of times an invalid codegroup is received, other than the /V/ code-group. /H/ denotes a special 4b5b codeword of the IEEE Std 802.3 Clause 24 100 Mb/s PCS layer, and /V/ denotes a special 8b10b codeword of the IEEE Std 802.3 Clause 36 1000 Mb/s PCS layer. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. Discontinuities of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of the ifCounterDiscontinuityTime object of the Interfaces Group MIB module." REFERENCE "IEEE Std 802.3, 30.5.1.1.14." ::= { dot3EponFecEntry 1} dot3EponFecAbility OBJECT-TYPE SYNTAX INTEGER { unknown(1), supported(2), unsupported(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "An object that indicates the support of operation of the optional FEC sublayer of the 1000BASE-PX PHY specified in IEEE Std 802.3, 65.2. unknown(1) value is assigned in the initialization, for non FEC support state or type not yet known. unsupported(3) value is assigned when the sublayer is not supported. supported(2) value is assigned when the sublayer is supported. This object is applicable for an OLT, with the same value for all virtual interfaces, and for an ONU. The FEC counters will have a zero value when the interface is not supporting FEC. The counters: dot3EponFecPCSCodingViolation - not affected by FEC ability. dot3EponFecCorrectedBlocks - has a zero value when dot3EponFecAbility is unknown(1) and unsupported(3). dot3EponFecUncorrectableBlocks - has a zero value when dot3EponFecAbility is unknown(1) and unsupported(3). dot3EponFecBufferHeadCodingViolation - has a zero value when dot3EponFecAbility is unknown(1) and unsupported(3)." REFERENCE "IEEE Std 802.3, 30.5.1.1.15." ::= { dot3EponFecEntry 2} dot3EponFecMode OBJECT-TYPE SYNTAX INTEGER { unknown(1), disabled(2), enabled(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "An object that defines the mode of operation of the optional FEC sublayer of the 1000BASE-PX PHY, specified in IEEE Std 802.3, 65.2, and reflects its state. A GET operation returns the current mode of operation of the PHY. A SET operation changes the mode of operation of the PHY to the indicated value. unknown(1) value is assigned in the initialization for non FEC support state or type not yet known. disabled(2) value is assigned when the FEC sublayer is operating in disabled mode. enabled(3) value is assigned when the FEC sublayer is operating in FEC mode. The write operation is not restricted in this document and can be done at any time. Changing dot3EponFecMode state can lead to disabling the Forward Error Correction on the respective interface, which can lead to a degradation of the optical link, and therefore may lead to an interruption of service for the users connected to the respective EPON interface. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. The counting of the FEC counters will stop when the FEC of the interface is disabled. The counters: dot3EponFecPCSCodingViolation - not affected by FEC mode. dot3EponFecCorrectedBlocks - stops counting when Rx_FEC is not enabled. (unknown(1) and disabled(2)). dot3EponFecUncorrectableBlocks - stops counting when Rx_FEC is not enabled (unknown(1) and disabled(2)). dot3EponFecBufferHeadCodingViolation - stops counting when Rx_FEC is not enabled (unknown(1) and disabled(2)). The object: dot3EponFecAbility - indicates the FEC ability and is not affected by the dot3EponFecMode object." REFERENCE "IEEE Std 802.3, 30.5.1.1.16." DEFVAL { unknown } ::= { dot3EponFecEntry 3} dot3EponFecCorrectedBlocks OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "For 1000BASE-PX, 10GBASE-PR or 10/1GBASE-PRX PHYs, it is a count of corrected FEC blocks. This counter will not increment for other PHY Types. Increment the counter by one for each received block that is corrected by the FEC function in the PHY. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. Discontinuities of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of the ifCounterDiscontinuityTime object of the Interfaces Group MIB module." REFERENCE "IEEE Std 802.3, 30.5.1.1.17." ::= { dot3EponFecEntry 4} dot3EponFecUncorrectableBlocks OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "For 1000BASE-PX, 10GBASE-PR or 10/1GBASE-PRX PHYs, it is a count of uncorrectable FEC blocks. This counter will not increment for other PHY Types. Increment the counter by one for each FEC block that is determined to be uncorrectable by the FEC function in the PHY. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. Discontinuities of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of the ifCounterDiscontinuityTime object of the Interfaces Group MIB module." REFERENCE "IEEE Std 802.3, 30.5.1.1.18." ::= { dot3EponFecEntry 5} dot3EponFecBufferHeadCodingViolation OBJECT-TYPE SYNTAX Counter64 UNITS "octets" MAX-ACCESS read-only STATUS current DESCRIPTION "For a 1000 Mb/s operation, it is a count of the number of invalid code-group received directly from the link. The value has a meaning only in 1000 Mb/s mode and it is zero otherwise. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. Discontinuities of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of the ifCounterDiscontinuityTime object of the Interfaces Group MIB module." ::= { dot3EponFecEntry 6} -- ExtendedPackage managed object definitions dot3ExtPkgObjects OBJECT IDENTIFIER ::={dot3EponObjects 4} dot3ExtPkgControlObjects OBJECT IDENTIFIER ::= { dot3ExtPkgObjects 1} dot3ExtPkgControlTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot3ExtPkgControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of Extended package Control management objects. Entries in the table are control and status indication objects of an EPON interface, which are gathered in an extended package as an addition to the objects based on the IEEE Std 802.3, Clause 30, attributes. Each object has a row for every virtual link denoted by the corresponding ifIndex. The LLID field, as defined in the IEEE Std 802.3, is a 2-byte register (15-bit field and a broadcast bit) limiting the number of virtual links to 32768. Typically the number of expected virtual links in a PON is like the number of ONUs, which is 32-64, plus an additional entry for broadcast LLID." ::= { dot3ExtPkgControlObjects 1 } dot3ExtPkgControlEntry OBJECT-TYPE SYNTAX Dot3ExtPkgControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Extended package Control table. Rows exist for an OLT interface and an ONU interface. A row in the table is denoted by the ifIndex of the link and it is created when the ifIndex is created. The rows in the table for an ONU interface are created at system initialization. The row in the table corresponding to the OLT ifIndex and the row corresponding to the broadcast virtual link are created at system initialization. A row in the table corresponding to the ifIndex of a virtual links is created when a virtual link is established (ONU registers) and deleted when the virtual link is deleted (ONU deregisters)." INDEX { ifIndex} ::= { dot3ExtPkgControlTable 1 } Dot3ExtPkgControlEntry ::= SEQUENCE { dot3ExtPkgObjectReset INTEGER, dot3ExtPkgObjectPowerDown TruthValue, dot3ExtPkgObjectNumberOfLLIDs Unsigned32, dot3ExtPkgObjectFecEnabled INTEGER, dot3ExtPkgObjectReportMaximumNumQueues Unsigned32, dot3ExtPkgObjectRegisterAction INTEGER } dot3ExtPkgObjectReset OBJECT-TYPE SYNTAX INTEGER { running(1), reset(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to reset the EPON interface. The interface may be unavailable while the reset occurs and data may be lost. Setting this object to running(1) will cause the interface to enter into running mode. Setting this object to reset(2) will cause the interface to go into reset mode. When getting running(1), the interface is in running mode. When getting reset(2), the interface is in reset mode. The write operation is not restricted in this document and can be done at any time. Changing dot3ExtPkgObjectReset state can lead to a reset of the respective interface, leading to an interruption of service for the users connected to the respective EPON interface. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. A reset for a specific virtual interface resets only this virtual interface and not the physical interface. Thus, a virtual link that is malfunctioning can be reset without affecting the operation of other virtual interfaces. The reset can cause Discontinuities in the values of the counters of the interface, similar to re-initialization of the management system. Discontinuity should be indicated by the ifCounterDiscontinuityTime object of the Interfaces Group MIB module." DEFVAL { running } ::= { dot3ExtPkgControlEntry 1 } dot3ExtPkgObjectPowerDown OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to power down the EPON interface. The interface may be unavailable while the power down occurs and data may be lost. Setting this object to true(1) will cause the interface to enter into power down mode. Setting this object to false(2) will cause the interface to go out of power down mode. When getting true(1), the interface is in power down mode. When getting false(2), the interface is not in power down mode. The write operation is not restricted in this document and can be done at any time. Changing dot3ExtPkgObjectPowerDown state can lead to a power down of the respective interface, leading to an interruption of service of the users connected to the respective EPON interface. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. A power down/up of a specific virtual interface affects only the virtual interface and not the physical interface. Hence a virtual link, which needs a certain handling, can be powered down and then powered up without disrupting the operation of other virtual interfaces. The object is relevant when the admin state of the interface is active as set by the dot3MpcpAdminState." DEFVAL { false } ::= { dot3ExtPkgControlEntry 2 } dot3ExtPkgObjectNumberOfLLIDs OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "A read only object that indicates the number of registered LLIDs. The initialization value is 0. This object is applicable for an OLT with the same value for all virtual interfaces and for an ONU. The LLID field, as defined in the IEEE Std 802.3, is a 2-byte register (15-bit field and a broadcast bit) limiting the number of virtual links to 32768. Typically the number of expected virtual links in a PON is like the number of ONUs, which is 32-64, plus an additional entry for broadcast LLID. At the ONU the number of LLIDs for an interface is one." ::= { dot3ExtPkgControlEntry 3 } dot3ExtPkgObjectFecEnabled OBJECT-TYPE SYNTAX INTEGER { noFecEnabled(1), fecTxEnabled(2), fecRxEnabled(3), fecTxRxEnabled(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "An object defining the FEC mode of operation of the interface, and indicating its state. The modes defined in this object are extensions to the FEC modes defined in the dot3EponFecMode object. When noFECEnabled(1), the interface does not enable FEC mode. When fecTxEnabled(2), the interface enables the FEC transmit mode. When fecRxEnabled(3), the interface enables the FEC receive mode. When fecTxRxEnabled(4), the interface enables the FEC transmit and receive mode. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. The FEC counters are referring to the receive path. The FEC counters will stop when the FEC receive mode of the interface is disabled, as defined by fecRxEnabled(3) and fecTxRxEnabled(4) values. The counters: dot3EponFecPCSCodingViolation - not affected by FEC mode. dot3EponFecCorrectedBlocks - stops counting when Rx_FEC is not enabled (noFecEnabled(1) and fecTxEnabled(2)). dot3EponFecUncorrectableBlocks - stops counting when Rx_FEC is not enabled (noFecEnabled(1) and fecTxEnabled(2)). dot3EponFecBufferHeadCodingViolation - stops counting when Rx_FEC is not enabled (noFecEnabled(1) and fecTxEnabled(2)). The objects: dot3EponFecAbility - indicates the FEC ability and is not affected by the FEC mode. dot3EponFecMode - indicates the FEC mode for combined RX and TX. The write operation is not restricted in this document and can be done at any time. Changing dot3ExtPkgObjectFecEnabled state can lead to disabling the Forward Error Correction on the respective interface, which can lead to a degradation of the optical link, and therefore may lead to an interruption of service for the users connected to the respective EPON interface." DEFVAL { noFecEnabled } ::= { dot3ExtPkgControlEntry 4 } dot3ExtPkgObjectReportMaximumNumQueues OBJECT-TYPE SYNTAX Unsigned32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "An object, that defines the maximal number of queues in the REPORT message as defined in IEEE Std 802.3, Clause 64. For further information please see the description of the queue table. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface." DEFVAL { 0 } ::= { dot3ExtPkgControlEntry 5 } dot3ExtPkgObjectRegisterAction OBJECT-TYPE SYNTAX INTEGER { none(1), register(2), deregister(3), reregister(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "An object configuring the registration state of an interface, and indicating its registration state. Write operation changes the registration state to its new value. Read operation returns the value of the state. The registration state is reflected in this object and in the dot3MpcpRegistrationState object. none(1) indicates an unknown state, register(2) indicates a registered LLID, deregister(3) indicates a deregistered LLID, reregister(4) indicates an LLID that is reregistering. The following list describes the operation of the interface, as specified in the IEEE Std 802.3, when a write operation is setting a value. none(1) - not doing any action. register(2) - registering an LLID that has been requested for registration (The LLID is in registering mode. dot3MpcpRegistrationState - registering(2) ). deregister(3) - deregisters an LLID that is registered (dot3MpcpRegistrationState - registered(3) ). reregister(4) - reregister an LLID that is registered (dot3MpcpRegistrationState - registered(3) ). The behavior of an ONU and OLT interfaces, at each one of the detailed operation at each state, is described in the registration state machine of figure 64-22, IEEE Std 802.3. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface. The write operation is not restricted in this document and can be done at any time. Changing dot3ExtPkgObjectRegisterAction state can lead to a change in the registration state of the respective interface leading to a deregistration and an interruption of service of the users connected to the respective EPON interface." DEFVAL { none } ::= { dot3ExtPkgControlEntry 6 } dot3ExtPkgQueueTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot3ExtPkgQueueEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of the extended package objects for queue management. The IEEE Std 802.3 MPCP defines a report message of the occupancy of the transmit queues for the feedback BW request from the ONUs. These queues serve the uplink transmission of the ONU and data is gathered there until the ONU is granted for transmission. The management table of the queues is added here mainly to control the reporting and to gather some statistics of their operation. This table is not duplicating existing management objects of bridging queues, specified in IEEE Std 802.1D, since the existence of a dedicated transmit queuing mechanism is implied in the IEEE Std 802.3, and the ONU may be a device that is not a bridge with embedded bridging queues. The format of the REPORT message, as specified in IEEE Std 802.3, is presented below: +-----------------------------------+ | Destination Address | +-----------------------------------+ | Source Address | +-----------------------------------+ | Length/Type | +-----------------------------------+ | OpCode | +-----------------------------------+ | TimeStamp | +-----------------------------------+ | Number of queue Sets | +-----------------------------------+ /|\ | Report bitmap | | +-----------------------------------+ | | Queue 0 report | | +-----------------------------------+ | repeated for | Queue 1 report | | every +-----------------------------------+ | queue_set | Queue 2 report | | +-----------------------------------+ | | Queue 3 report | | +-----------------------------------+ | | Queue 4 report | | +-----------------------------------+ | | Queue 5 report | | +-----------------------------------+ | | Queue 6 report | | +-----------------------------------+ | | Queue 7 report | | +-----------------------------------+ \|/ | Pad/reserved | +-----------------------------------+ | FCS | +-----------------------------------+ The 'Queue report' field reports the occupancy of each uplink transmission queue. The number of queue sets defines the number of the reported sets, as would be explained in the description of the dot3ExtPkgQueueSetsTable table. For each set the report bitmap defines which queue is present in the report, meaning that although the MPCP REPORT message can report up to 8 queues in a REPORT message, the actual number is flexible. The Queue table has a variable size that is limited by the dot3ExtPkgObjectReportMaximumNumQueues object, as an ONU can have fewer queues to report. The entries in the table are control and status indication objects for managing the queues of an EPON interface that are gathered in an extended package as an addition to the objects that are based on the IEEE Std 802.3 attributes. Each object has a row for every virtual link and for every queue in the report. The LLID field, as defined in the IEEE Std 802.3, is a 2-byte register (15-bit field and a broadcast bit) limiting the number of virtual links to 32768. Typically the number of expected virtual links in a PON is like the number of ONUs, which is 32-64, plus an additional entry for broadcast LLID. The number of queues is between 0 and 7 and limited by dot3ExtPkgObjectReportMaximumNumQueues." ::= { dot3ExtPkgControlObjects 2 } dot3ExtPkgQueueEntry OBJECT-TYPE SYNTAX Dot3ExtPkgQueueEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Extended package Queue table. At the OLT, the rows exist for each ifIndex and dot3QueueIndex. At the ONU, rows exist for the single ifIndex for each dot3QueueIndex. Rows in the table are created when the ifIndex of the link is created. A set of rows per queue are added for each ifIndex, denoted by the dot3QueueIndex. A set of rows per queue in the table, for an ONU interface, are created at the system initialization. A set of rows per queue in the table, corresponding to the OLT ifIndex and a set of rows per queue corresponding to the broadcast virtual link, are created at the system initialization. A set of rows per queue in the table, corresponding to the ifIndex of a virtual link, are created when the virtual link is established (ONU registers), and deleted when the virtual link is deleted (ONU deregisters)." INDEX { ifIndex, dot3QueueIndex } ::= { dot3ExtPkgQueueTable 1 } Dot3ExtPkgQueueEntry ::= SEQUENCE { dot3QueueIndex Unsigned32, dot3ExtPkgObjectReportNumThreshold Unsigned32, dot3ExtPkgObjectReportMaximumNumThreshold Unsigned32, dot3ExtPkgStatTxFramesQueue Counter64, dot3ExtPkgStatRxFramesQueue Counter64, dot3ExtPkgStatDroppedFramesQueue Counter64 } dot3QueueIndex OBJECT-TYPE SYNTAX Unsigned32 (0..7) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An object that identifies an index for the queue table reflecting the queue index of the queues that are reported in the MPCP REPORT message as defined in IEEE Std 802.3, Clause 64. The number of queues is between 0 and 7, and limited by dot3ExtPkgObjectReportMaximumNumQueues." ::= { dot3ExtPkgQueueEntry 1 } dot3ExtPkgObjectReportNumThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "An object that defines the number of thresholds for each queue in the REPORT message as defined in IEEE Std 802.3, Clause 64. Each queue_set reporting will provide information on the queue occupancy of frames below the matching Threshold. Read operation reflects the number of thresholds. Write operation sets the number of thresholds for each queue. The write operation is not restricted in this document and can be done at any time. Value cannot exceed the maximal value defined by the dot3ExtPkgObjectReportMaximumNumThreshold object. Changing dot3ExtPkgObjectReportNumThreshold can lead to a change in the reporting of the ONU interface and therefore to a change in the bandwidth allocation of the respective interface. This change may lead a degradation or an interruption of service of the users connected to the respective EPON interface. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface and for each queue. At the ONU, it has a distinct value for each queue." DEFVAL { 0 } ::= { dot3ExtPkgQueueEntry 2 } dot3ExtPkgObjectReportMaximumNumThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "An object, that defines the maximal number of thresholds for each queue in the REPORT message as defined in IEEE Std 802.3, Clause 64. Each queue_set reporting will provide information on the queue occupancy of frames below the matching Threshold. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface and for each queue. At the ONU, it has a distinct value for each queue." DEFVAL { 0 } ::= { dot3ExtPkgQueueEntry 3 } dot3ExtPkgStatTxFramesQueue OBJECT-TYPE SYNTAX Counter64 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a frame transmission occurs from the corresponding 'Queue'. Increment the counter by one for each frame transmitted, which is an output of the 'Queue'. The 'Queue' marking matches the REPORT MPCP message Queue field as defined in IEEE Std 802.3, Clause 64. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface and for each queue. At the ONU, it has a distinct value for each queue. At the OLT the value should be zero. Discontinuities of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of the ifCounterDiscontinuityTime object of the Interfaces Group MIB module." ::= { dot3ExtPkgQueueEntry 4} dot3ExtPkgStatRxFramesQueue OBJECT-TYPE SYNTAX Counter64 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a frame reception occurs from the corresponding 'Queue'. Increment the counter by one for each frame received, which is an input to the corresponding 'Queue'. The 'Queue' marking matches the REPORT MPCP message Queue field as defined in IEEE Std 802.3, Clause 64. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface and for each queue. At the ONU, it has a distinct value for each queue. Discontinuities of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of the ifCounterDiscontinuityTime object of the Interfaces Group MIB module." ::= { dot3ExtPkgQueueEntry 5} dot3ExtPkgStatDroppedFramesQueue OBJECT-TYPE SYNTAX Counter64 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a frame drop occurs from the corresponding 'Queue'. Increment the counter by one for each frame dropped from the corresponding 'Queue'. The 'Queue' marking matches the REPORT MPCP message Queue field as defined in IEEE Std 802.3, Clause 64. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface and for each queue. At the ONU, it has a distinct value for each queue. At the OLT, the value should be zero. Discontinuities of this counter can occur at re-initialization of the management system and at other times, as indicated by the value of the ifCounterDiscontinuityTime object of the Interfaces Group MIB module." ::= { dot3ExtPkgQueueEntry 6} dot3ExtPkgQueueSetsTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot3ExtPkgQueueSetsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of Extended package objects used for the management of the queue_sets. Entries are control and status indication objects of an EPON interface, which are gathered in an extended package as an addition to the objects based on the IEEE Std 802.3 attributes. The objects in this table are specific for the queue_sets, which are reported in the MPCP REPORT message as defined in IEEE Std 802.3, Clause 64. The IEEE Std 802.3 MPCP defines a report message of the occupancy of the transmit queues for the feedback BW request from the ONUs. These queues serve the uplink transmission of the ONU and data is gathered there until the ONU is granted for transmission. The management table of the queues_sets is added here mainly to control the reporting and to gather some statistics of their operation. This table is not duplicating existing management objects of bridging queues, specified in IEEE Std 802.1D, since the existence of a dedicated transmit queuing mechanism is implied in the IEEE Std 802.3, and the ONU may be a device that is not a bridge with embedded bridging queues. The format of the REPORT message, as specified in IEEE Std 802.3, is presented below: +-----------------------------------+ | Destination Address | +-----------------------------------+ | Source Address | +-----------------------------------+ | Length/Type | +-----------------------------------+ | OpCode | +-----------------------------------+ | TimeStamp | +-----------------------------------+ | Number of queue Sets | +-----------------------------------+ /|\ | Report bitmap | | +-----------------------------------+ | | Queue 0 report | | +-----------------------------------+ | repeated for | Queue 1 report | | every +-----------------------------------+ | queue_set | Queue 2 report | | +-----------------------------------+ | | Queue 3 report | | +-----------------------------------+ | | Queue 4 report | | +-----------------------------------+ | | Queue 5 report | | +-----------------------------------+ | | Queue 6 report | | +-----------------------------------+ | | Queue 7 report | | +-----------------------------------+ \|/ | Pad/reserved | +-----------------------------------+ | FCS | +-----------------------------------+ As can be seen from the message format, the ONU interface reports of the status of up to 8 queues and it can report in a single MPCP REPORT message of a few sets of queues. The number of queue_sets defines the number of the reported sets, and it can reach a value of up to 8. It means that an ONU can hold a variable number of sets between 0 and 7. The dot3ExtPkgQueueSetsTable table has a variable queue_set size that is limited by the dot3ExtPkgObjectReportMaximumNumThreshold object as an ONU can have fewer queue_sets to report. The 'Queue report' field reports the occupancy of each uplink transmission queue. The queue_sets can be used to report the occupancy of the queues in a few levels as to allow granting, in an accurate manner, of only part of the data available in the queues. A Threshold is defined for each queue_set to define the level of the queue that is counted for the report of the occupancy. The threshold is reflected in the queue_set table by the dot3ExtPkgObjectReportThreshold object. For each queue set, the report bitmap defines which queues are present in the report, meaning that although the MPCP REPORT message can report of up to 8 queues in a REPORT message, the actual number is flexible. The dot3ExtPkgQueueSetsTable table has a variable queue size that is limited by the dot3ExtPkgObjectReportMaximumNumQueues object as an ONU can have fewer queues to report. Each object has a row for every virtual link, for each queue in the report and for each queue_set in the queue. The LLID field, as defined in the IEEE Std 802.3, is a 2-byte register (15-bit field and a broadcast bit) limiting the number of virtual links to 32768. Typically the number of expected virtual links in a PON is like the number of ONUs, which is 32-64, plus an additional entry for broadcast LLID. The number of queues is between 0 and 7 and limited by dot3ExtPkgObjectReportMaximumNumQueues. The number of queues_sets is between 0 and 7 and limited by dot3ExtPkgObjectReportMaximumNumThreshold." ::= { dot3ExtPkgControlObjects 3 } dot3ExtPkgQueueSetsEntry OBJECT-TYPE SYNTAX Dot3ExtPkgQueueSetsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Extended package queue_set table. At the OLT, the rows exist for each ifIndex, dot3QueueSetQueueIndex and dot3QueueSetIndex. At the ONU, rows exist for the single ifIndex, for each dot3QueueSetQueueIndex and dot3QueueSetIndex. Rows in the table are created when the ifIndex of the link is created. A set of rows per queue and per queue_set are added for each ifIndex, denoted by dot3QueueSetIndex and dot3QueueSetQueueIndex. A set of rows per queue and per queue_set in the table, for an ONU interface are created at system initialization. A set of rows per queue and per queue_Set in the table, corresponding to the OLT ifIndex and a set of rows per queue and per queue_set, corresponding to the broadcast virtual link, are created at system initialization. A set of rows per queue and per queue_set in the table, corresponding to the ifIndex of a virtual link are created when the virtual link is established (ONU registers) and deleted when the virtual link is deleted (ONU deregisters)." INDEX { ifIndex, dot3QueueSetQueueIndex,dot3QueueSetIndex} ::= { dot3ExtPkgQueueSetsTable 1 } Dot3ExtPkgQueueSetsEntry ::= SEQUENCE { dot3QueueSetQueueIndex Unsigned32, dot3QueueSetIndex Unsigned32, dot3ExtPkgObjectReportThreshold Unsigned32 } dot3QueueSetQueueIndex OBJECT-TYPE SYNTAX Unsigned32 (0..7) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An object that identifies the queue index for the dot3ExtPkgQueueSetsTable table. The queues are reported in the MPCP REPORT message as defined in IEEE Std 802.3, Clause 64. The number of queues is between 0 and 7, and limited by dot3ExtPkgObjectReportMaximumNumQueues. Value corresponds to the dot3QueueIndex of the queue table." ::= { dot3ExtPkgQueueSetsEntry 1 } dot3QueueSetIndex OBJECT-TYPE SYNTAX Unsigned32 (0..7) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An object that identifies the queue_set index for the dot3ExtPkgQueueSetsTable table. The queues are reported in the MPCP REPORT message as defined in IEEE Std 802.3, Clause 64. The number of queues_sets is between 0 and 7, and limited by dot3ExtPkgObjectReportMaximumNumThreshold." ::= { dot3ExtPkgQueueSetsEntry 2 } dot3ExtPkgObjectReportThreshold OBJECT-TYPE SYNTAX Unsigned32 UNITS "TQ (16 ns)" MAX-ACCESS read-write STATUS current DESCRIPTION "An object that defines the value of a threshold report for each queue_set in the REPORT message as defined in IEEE Std 802.3, Clause 64. The number of sets for each queue is dot3ExtPkgObjectReportNumThreshold. In the REPORT message, each queue_set reporting will provide information on the occupancy of the queues for frames below the matching Threshold. The value returned shall be in Time quanta (TQ), which is 16 ns or 2 octets increments. Read operation provides the threshold value. Write operation sets the value of the threshold. The write operation is not restricted in this document and can be done at any time. Changing dot3ExtPkgObjectReportThreshold can lead to a change in the reporting of the ONU interface and therefore to a change in the bandwidth allocation of the respective interface. This change may lead a degradation or an interruption of service for the users connected to the respective EPON interface. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface, for each queue and for each queue_set. At the ONU, it has a distinct value for each queue and for each queue_set." DEFVAL { 0 } ::= { dot3ExtPkgQueueSetsEntry 3 } --Optical Interface status tables dot3ExtPkgOptIfTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot3ExtPkgOptIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table defines the control and status indication objects for the optical interface of the EPON interface. Each object has a row for every virtual link denoted by the corresponding ifIndex. The LLID field, as defined in the IEEE Std 802.3, is a 2-byte register (15-bit field and a broadcast bit) limiting the number of virtual links to 32768. Typically the number of expected virtual links in a PON is like the number of ONUs, which is 32-64, plus an additional entry for broadcast LLID. Although the optical interface is a physical interface, there is a row in the table for each virtual interface. The reason for having a separate row for each virtual link is that the OLT has a separate link for each one of the ONUs. For instance, ONUs could be in different distances with different link budgets and different receive powers, therefore having different power alarms. It is quite similar to a case of different physical interfaces." ::= { dot3ExtPkgControlObjects 5} dot3ExtPkgOptIfEntry OBJECT-TYPE SYNTAX Dot3ExtPkgOptIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the optical interface table of the EPON interface. Rows exist for an OLT interface and an ONU interface. A row in the table is denoted by the ifIndex of the link and it is created when the ifIndex is created. The rows in the table for an ONU interface are created at system initialization. The row in the table corresponding to the OLT ifIndex and the row corresponding to the broadcast virtual link are created at system initialization. A row in the table corresponding to the ifIndex of a virtual links is created when a virtual link is established (ONU registers) and deleted when the virtual link is deleted (ONU deregisters)." INDEX { ifIndex } ::= { dot3ExtPkgOptIfTable 1 } Dot3ExtPkgOptIfEntry ::= SEQUENCE { dot3ExtPkgOptIfSuspectedFlag TruthValue, dot3ExtPkgOptIfInputPower Integer32, dot3ExtPkgOptIfLowInputPower Integer32, dot3ExtPkgOptIfHighInputPower Integer32, dot3ExtPkgOptIfLowerInputPowerThreshold Integer32, dot3ExtPkgOptIfUpperInputPowerThreshold Integer32, dot3ExtPkgOptIfOutputPower Integer32, dot3ExtPkgOptIfLowOutputPower Integer32, dot3ExtPkgOptIfHighOutputPower Integer32, dot3ExtPkgOptIfLowerOutputPowerThreshold Integer32, dot3ExtPkgOptIfUpperOutputPowerThreshold Integer32, dot3ExtPkgOptIfSignalDetect TruthValue, dot3ExtPkgOptIfTransmitAlarm TruthValue, dot3ExtPkgOptIfTransmitEnable TruthValue } dot3ExtPkgOptIfSuspectedFlag OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This object is a reliability indication. If true, the data in this entry may be unreliable. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface." ::= { dot3ExtPkgOptIfEntry 1 } dot3ExtPkgOptIfInputPower OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 dbm" MAX-ACCESS read-only STATUS current DESCRIPTION "The optical power monitored at the input. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface." ::= { dot3ExtPkgOptIfEntry 2 } dot3ExtPkgOptIfLowInputPower OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 dbm" MAX-ACCESS read-only STATUS current DESCRIPTION "The lowest optical power monitored at the input during the current 15-minute interval. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface." ::= { dot3ExtPkgOptIfEntry 3 } dot3ExtPkgOptIfHighInputPower OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 dbm" MAX-ACCESS read-only STATUS current DESCRIPTION "The highest optical power monitored at the input during the current 15-minute interval. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface." ::= { dot3ExtPkgOptIfEntry 4 } dot3ExtPkgOptIfLowerInputPowerThreshold OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 dbm" MAX-ACCESS read-write STATUS current DESCRIPTION "The lower limit threshold on input power. If dot3ExtPkgOptIfInputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. Reading will present the threshold value. Writing will set the value of the threshold. The write operation is not restricted in this document and can be done at any time. Changing dot3ExtPkgOptIfLowerInputPowerThreshold can lead to a Threshold Crossing Alert (TCA) being sent for the respective interface. This alert may be leading to an interruption of service for the users connected to the respective EPON interface, depending on the system action on such an alert. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface." ::= { dot3ExtPkgOptIfEntry 5 } dot3ExtPkgOptIfUpperInputPowerThreshold OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 dbm" MAX-ACCESS read-write STATUS current DESCRIPTION "The upper limit threshold on input power. If dot3ExtPkgOptIfInputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. Reading will present the threshold value. Writing will set the value of the threshold. The write operation is not restricted in this document and can be done at any time. Changing dot3ExtPkgOptIfUpperInputPowerThreshold can lead to a Threshold Crossing Alert (TCA) being sent for the respective interface. This alert may be leading to an interruption of service for the users connected to the respective EPON interface, depending on the system action on such an alert. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface." ::= { dot3ExtPkgOptIfEntry 6 } dot3ExtPkgOptIfOutputPower OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 dbm" MAX-ACCESS read-only STATUS current DESCRIPTION "The optical power monitored at the output. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface." ::= { dot3ExtPkgOptIfEntry 7 } dot3ExtPkgOptIfLowOutputPower OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 dbm" MAX-ACCESS read-only STATUS current DESCRIPTION "The lowest optical power monitored at the output during the current 15-minute interval. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface." ::= { dot3ExtPkgOptIfEntry 8 } dot3ExtPkgOptIfHighOutputPower OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 dbm" MAX-ACCESS read-only STATUS current DESCRIPTION "The highest optical power monitored at the output during the current 15-minute interval. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface." ::= { dot3ExtPkgOptIfEntry 9 } dot3ExtPkgOptIfLowerOutputPowerThreshold OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 dbm" MAX-ACCESS read-write STATUS current DESCRIPTION "The lower limit threshold on output power. If dot3ExtPkgOptIfOutputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. Reading will present the threshold value. Writing will set the value of the threshold. The write operation is not restricted in this document and can be done at any time. Changing dot3ExtPkgOptIfLowerOutputPowerThreshold can lead to a Threshold Crossing Alert (TCA) being sent for the respective interface. This alert may be leading to an interruption of service for the users connected to the respective EPON interface, depending on the system action on such an alert. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface." ::= { dot3ExtPkgOptIfEntry 10 } dot3ExtPkgOptIfUpperOutputPowerThreshold OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 dbm" MAX-ACCESS read-write STATUS current DESCRIPTION "The upper limit threshold on output power. If dot3ExtPkgOptIfOutputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. Reading will present the threshold value. Writing will set the value of the threshold. The write operation is not restricted in this document and can be done at any time. Changing dot3ExtPkgOptIfUpperOutputPowerThreshold can lead to a Threshold Crossing Alert (TCA) being sent for the respective interface. This alert may be leading to an interruption of service of the users connected to the respective EPON interface, depending on the system action on such an alert. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface." ::= { dot3ExtPkgOptIfEntry 11 } dot3ExtPkgOptIfSignalDetect OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "When getting true(1), there is a valid optical signal at the receive that is above the optical power level for signal detection. When getting false(2) the optical signal at the receive is below the optical power level for signal detection. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface." DEFVAL { false } ::= { dot3ExtPkgOptIfEntry 12 } dot3ExtPkgOptIfTransmitAlarm OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "When getting true(1) there is a non-valid optical signal at the transmit of the interface, either a higher level or lower level than expected. When getting false(2) the optical signal at the transmit is valid and in the required range. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface." DEFVAL { false } ::= { dot3ExtPkgOptIfEntry 13 } dot3ExtPkgOptIfTransmitEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this object to true(1) will cause the optical interface to start transmission (according to the control protocol specified for the logical interface). Setting this object to false(2) will cause the interface to stop the optical transmission. When getting true(1), the optical interface is in transmitting mode (obeying to the logical control protocol). When getting false(2), the optical interface is not in transmitting mode. The write operation is not restricted in this document and can be done at any time. Changing dot3ExtPkgOptIfTransmitEnable state can lead to a halt in the optical transmission of the respective interface leading to an interruption of service of the users connected to the respective EPON interface. The object is relevant when the admin state of the interface is active as set by the dot3MpcpAdminState. This object is applicable for an OLT and an ONU. At the OLT it, has a distinct value for each virtual interface." DEFVAL { false } ::= { dot3ExtPkgOptIfEntry 14 } -- -- The MulticastIDs Table -- dot3RecognizedMulticastIDsTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot3RecognizedMulticastIDsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of MulticastIDs to be recognized by this device." REFERENCE "IEEE Std 802.3, 30.3.5.1.25." ::= { dot3EponObjects 5 } dot3RecognizedMulticastIDsEntry OBJECT-TYPE SYNTAX Dot3RecognizedMulticastIDsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table of MulticastIDs to be recognized by this device." INDEX { ifIndex, dot3RecognizedMulticastIDIndex } ::= { dot3RecognizedMulticastIDsTable 1 } Dot3RecognizedMulticastIDsEntry ::= SEQUENCE { dot3RecognizedMulticastIDIndex Unsigned32, dot3RecognizedMulticastID Unsigned32 } dot3RecognizedMulticastIDIndex OBJECT-TYPE SYNTAX Unsigned32 (0..127) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An index into the table of MulticastIDs to be recognized by this device." ::= { dot3RecognizedMulticastIDsEntry 1 } dot3RecognizedMulticastID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "An Uunsigned32 representing a single MulticastID to be recognized by this device." REFERENCE "IEEE Std 802.3, 30.3.5.1.25." ::= { dot3RecognizedMulticastIDsEntry 2 } -- Conformance statements -- Conformance Groups dot3EponGroups OBJECT IDENTIFIER ::= { dot3EponConformance 1 } dot3MpcpGroupBase OBJECT-GROUP OBJECTS { dot3MpcpOperStatus, dot3MpcpAdminState, dot3MpcpMode, dot3MpcpSyncTime, dot3MpcpLinkID, dot3MpcpRemoteMACAddress, dot3MpcpRegistrationState, dot3MpcpMaximumPendingGrants, dot3MpcpTransmitElapsed, dot3MpcpReceiveElapsed, dot3MpcpRoundTripTime } STATUS current DESCRIPTION "A collection of objects of dot3 Mpcp Control entity state definition. Objects are per LLID." ::= { dot3EponGroups 1 } dot3MpcpGroupStat OBJECT-GROUP OBJECTS { dot3MpcpMACCtrlFramesTransmitted, dot3MpcpMACCtrlFramesReceived, dot3MpcpDiscoveryWindowsSent, dot3MpcpDiscoveryTimeout, dot3MpcpTxRegRequest, dot3MpcpRxRegRequest, dot3MpcpTxRegAck, dot3MpcpRxRegAck, dot3MpcpTxReport, dot3MpcpRxReport, dot3MpcpTxGate, dot3MpcpRxGate, dot3MpcpTxRegister, dot3MpcpRxRegister } STATUS current DESCRIPTION "A collection of objects of dot3 Mpcp Statistics. Objects are per LLID." ::= { dot3EponGroups 2 } dot3OmpeGroupID OBJECT-GROUP OBJECTS { dot3OmpEmulationType } STATUS current DESCRIPTION "A collection of objects of dot3 OMP emulation entity state definition. Objects are per LLID." ::= { dot3EponGroups 3 } dot3OmpeGroupStat OBJECT-GROUP OBJECTS { dot3OmpEmulationSLDErrors, dot3OmpEmulationCRC8Errors, dot3OmpEmulationBadLLID, dot3OmpEmulationGoodLLID, dot3OmpEmulationOnuPonCastLLID, dot3OmpEmulationOltPonCastLLID, dot3OmpEmulationBroadcastBitNotOnuLlid, dot3OmpEmulationOnuLLIDNotBroadcast, dot3OmpEmulationBroadcastBitPlusOnuLlid, dot3OmpEmulationNotBroadcastBitNotOnuLlid } STATUS current DESCRIPTION "A collection of objects of dot3 OMP emulation Statistics. Objects are per LLID." ::= { dot3EponGroups 4 } dot3EponFecGroupAll OBJECT-GROUP OBJECTS { dot3EponFecPCSCodingViolation, dot3EponFecAbility, dot3EponFecMode, dot3EponFecCorrectedBlocks, dot3EponFecUncorrectableBlocks, dot3EponFecBufferHeadCodingViolation } STATUS current DESCRIPTION "A collection of objects of dot3 FEC group control and statistics. Objects are per LLID." ::= { dot3EponGroups 5 } dot3ExtPkgGroupControl OBJECT-GROUP OBJECTS { dot3ExtPkgObjectReset, dot3ExtPkgObjectPowerDown, dot3ExtPkgObjectNumberOfLLIDs, dot3ExtPkgObjectFecEnabled, dot3ExtPkgObjectReportMaximumNumQueues, dot3ExtPkgObjectRegisterAction } STATUS current DESCRIPTION "A collection of objects of dot3ExtPkg control definition. Objects are per LLID." ::= { dot3EponGroups 6 } dot3ExtPkgGroupQueue OBJECT-GROUP OBJECTS { dot3ExtPkgObjectReportNumThreshold, dot3ExtPkgObjectReportMaximumNumThreshold, dot3ExtPkgStatTxFramesQueue, dot3ExtPkgStatRxFramesQueue, dot3ExtPkgStatDroppedFramesQueue } STATUS current DESCRIPTION "A collection of objects of dot3ExtPkg Queue control. Objects are per LLID, per queue." ::= { dot3EponGroups 7 } dot3ExtPkgGroupQueueSets OBJECT-GROUP OBJECTS { dot3ExtPkgObjectReportThreshold } STATUS current DESCRIPTION "A collection of objects of dot3ExtPkg queue_set control. Objects are per LLID, per queue, per queue_set." ::= { dot3EponGroups 8 } dot3ExtPkgGroupOptIf OBJECT-GROUP OBJECTS { dot3ExtPkgOptIfSuspectedFlag, dot3ExtPkgOptIfInputPower, dot3ExtPkgOptIfLowInputPower, dot3ExtPkgOptIfHighInputPower, dot3ExtPkgOptIfLowerInputPowerThreshold, dot3ExtPkgOptIfUpperInputPowerThreshold, dot3ExtPkgOptIfOutputPower, dot3ExtPkgOptIfLowOutputPower, dot3ExtPkgOptIfHighOutputPower, dot3ExtPkgOptIfLowerOutputPowerThreshold, dot3ExtPkgOptIfUpperOutputPowerThreshold, dot3ExtPkgOptIfSignalDetect, dot3ExtPkgOptIfTransmitAlarm, dot3ExtPkgOptIfTransmitEnable } STATUS current DESCRIPTION "A collection of objects of control and status indication of the optical interface. Objects are per LLID." ::= { dot3EponGroups 9 } dot3EponGroupMulticastIDs OBJECT-GROUP OBJECTS { dot3RecognizedMulticastID } STATUS current DESCRIPTION "One of a set of MulticastIDs recognized by an EPON interface." ::= { dot3EponGroups 10 } -- Compliance statements dot3EponCompliances OBJECT IDENTIFIER ::= { dot3EponConformance 2 } dot3MPCPCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for MultiPoint Control Protocol interfaces." MODULE -- this module MANDATORY-GROUPS { dot3MpcpGroupBase} GROUP dot3MpcpGroupStat DESCRIPTION "This group is mandatory for all MPCP supporting interfaces for statistics collection." ::= { dot3EponCompliances 1} dot3OmpeCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for OMPEmulation interfaces." MODULE -- this module MANDATORY-GROUPS { dot3OmpeGroupID} GROUP dot3OmpeGroupStat DESCRIPTION "This group is mandatory for all OMPemulation supporting interfaces for statistics collection." ::= { dot3EponCompliances 2} dot3EponFecCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for FEC EPON interfaces. This group is mandatory for all FEC supporting interfaces for control and statistics collection." MODULE -- this module MANDATORY-GROUPS { dot3EponFecGroupAll } ::= { dot3EponCompliances 3} dot3ExtPkgCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for EPON Interfaces using the extended package." MODULE -- this module MANDATORY-GROUPS { dot3ExtPkgGroupControl } GROUP dot3ExtPkgGroupQueue DESCRIPTION " This group is mandatory for all EPON interfaces supporting REPORT queue management of the extended package." GROUP dot3ExtPkgGroupQueueSets DESCRIPTION " This group is mandatory for all EPON interfaces supporting REPORT queue_sets management of the extended package." GROUP dot3ExtPkgGroupOptIf DESCRIPTION "This group is mandatory for all EPON interfaces supporting optical interfaces management, of the extended package." ::= { dot3EponCompliances 4} dot3EponMulticastIDsCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for EPON Interfaces that support MulticastIDs." MODULE -- this module MANDATORY-GROUPS { dot3EponGroupMulticastIDs } ::= { dot3EponCompliances 5 } END