Looking through the 
proposaldetail spreadsheets I have received, I have seen some numbers that may 
may indicate discrepancies in interpretation and am sending this out as a 
clarification. This may or may not be relevant to you and does not imply an 
error in what you have submitted.
 
Since the most vocal 
debate on channel models has centered around ANEXT modeling, the entries called 
for in row 11 aim to understand sensitivity of your proposal to the ANEXT 
coefficient. This is not the same thing as the gap between SNR required and SNR 
available at the "Slicer input" of the DFE. To get the number requested, adjust 
the ANEXT coefficient so that the SNR available equals the SNR 
required.
 
I think some have 
submitted the gap between the SNR required and SNR available which is the more 
traditional interpretation of margin. It may make sense to include this number 
also.
 