Thread Links Date Links
Thread Prev Thread Next Thread Index Date Prev Date Next Date Index

Re: [STDS-802-3-400G] [PossibleSpam] Re: [STDS-802-3-400G] IEEE P802.3bs 200 Gb/s and 400 Gb/s Ethernet SMF Ad Hoc conference call



Mike,

The presentation that Pete referenced (prepared for next weeks Ad Hoc) is proposing to make the unstressed RX sensitivity more stringent by 0.9 dB, and increasing the SECQ for the SRS value by 0.9 dB.

 

Brian

 

From: Dudek, Mike [mailto:Mike.Dudek@xxxxxxxxxx]
Sent: Wednesday, June 21, 2017 11:03 AM
To: STDS-802-3-400G@xxxxxxxxxxxxxxxxx
Subject: [PossibleSpam] Re: [STDS-802-3-400G] IEEE P802.3bs 200 Gb/s and 400 Gb/s Ethernet SMF Ad Hoc conference call

 

The definition for unstressed receiver sensitivity has always been with zero stress.   Saying that SECQ = 0dB clarifies what is meant by zero stress.      It is harder for the Rx to achieve the BER with a SECQ of 0.9dB rather than SECQ of 0dB and we aren’t changing the Unstressed sensitivity  so I don’t understand why you are saying this makes the Rx unstressed sensitivity test harder.

 

From: Carlo Tosetti (ctosetti) [mailto:ctosetti@xxxxxxxxx]
Sent: Wednesday, June 21, 2017 1:53 AM
To: STDS-802-3-400G@xxxxxxxxxxxxxxxxx
Subject: Re: [STDS-802-3-400G] IEEE P802.3bs 200 Gb/s and 400 Gb/s Ethernet SMF Ad Hoc conference call

 

Ciao Peter

 

I have a question related to the added text in the notes on unstressed receiver sensitivity “…and is defined for a transmitter with SECQ of 0dB”.

 

Based on such value, the proposed change in TDECQ has an impact on the RX side, as it is captured by the corrections in unstressed sensitivity values: the same RX which was OK with the reference TX when using the old TDECQ definition is now not working anymore with the new TDECQ definition and needs an improvement of 0.9dB in the unstressed sensitivity.

 

I am wondering – but honestly I am not sure if this is physically sound and consistent with the new proposed TDECQ methodology: shouldn’t the note say instead “…and is defined for a transmitter with SECQ of 0.9dB” (admittedly this looks pretty ugly…)?

 

Thanks and regards

Carlo

 

“…non men che saver, dubbiar m'aggrata…” (Inferno - Canto XI)

 

.:|:.:|:. Carlo Tosetti | 

CISCO | TMG Technical Leader|

 

From: Anslow, Peter [mailto:panslow@xxxxxxxxx]
Sent: martedì 20 giugno 2017 21:47
To: STDS-802-3-400G@xxxxxxxxxxxxxxxxx
Subject: Re: [STDS-802-3-400G] IEEE P802.3bs 200 Gb/s and 400 Gb/s Ethernet SMF Ad Hoc conference call

 

Matt,

 

I think that the file I have generated for next week’s SMF Ad Hoc should answer your question:

http://www.ieee802.org/3/bs/public/adhoc/smf/17_06_27/anslow_02_0617_smf.pdf

 

Regards,

Pete Anslow | Senior Standards Advisor
43-51 Worship Street | London, EC2A 2DX, UK
Direct +44 2070 125535
|

 

From: Matt Traverso (mattrave) [mailto:mattrave@xxxxxxxxx]
Sent: 20 June 2017 04:16
To: Anslow, Peter <panslow@xxxxxxxxx>; STDS-802-3-400G@xxxxxxxxxxxxxxxxx; Jonathan King <jonathan.king@xxxxxxxxxxx>
Subject: RE: [STDS-802-3-400G] IEEE P802.3bs 200 Gb/s and 400 Gb/s Ethernet SMF Ad Hoc conference call

 

Hi Jonathan,

I’m sorry to have missed the most recent ad hoc where you presented king_01a_0617_smf.  I find myself confused as to what you mean by: “a similar decrease in the OMAouterminus TDECQ spec”.  Can you show an example with what would happen for the TX or RX table for any of the clause 122 PMD’s?

 

I think this all stems from a mixing of terms increase/decrease with negative numbers…

 

Thanks

--matt

 

 

logo_Grey

 

Matt Traverso

PRINCIPAL ENGINEER.ENGINEERING

mattrave@xxxxxxxxx

Cisco Systems, Inc.

3700 Cisco Way
SAN JOSE
95134
United States
cisco.com

 

 

 

 

 

From: Anslow, Peter [mailto:panslow@xxxxxxxxx]
Sent: Tuesday, June 13, 2017 1:12 AM
To: STDS-802-3-400G@xxxxxxxxxxxxxxxxx
Subject: [STDS-802-3-400G] IEEE P802.3bs 200 Gb/s and 400 Gb/s Ethernet SMF Ad Hoc conference call

 

Hi,

 

As previously announced, there is an SMF Ad Hoc meeting starting at 8:00 am Pacific today, Tuesday 13 June.

 

Attendees names and affiliations will be taken from the Webex participants list. Please use an e-mail address indicating affiliation when signing in. If you attend via phone only, or if your employer and affiliation are different, please send me an e-mail.

 

I currently have requests for 1 presentation so the draft agenda is:

 

 

  • Discussion

 

The presentation for this call is on the P802.3bs SMF Ad Hoc web page.

If you have any questions for the presenter(s) after the call, please ask the Ad Hoc Chair for contact details.

 

Peter Anslow from Ciena has invited you to join a meeting on the Web, using WebEx. Please join the meeting 5-10 minutes early so we may begin on time.

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Topic: "P802.3bs SMF Ad Hoc"

Date & Time: Every 2 weeks on Tuesday, from Tuesday, 13 June 2017, to Tuesday, 27 June 2017 at 16:00, GMT Summer Time (London, GMT+01:00)

To join web meeting click here:
https://ciena.webex.com/ciena/j.php?MTID=m8af2937bfb4b6fd299ccb5ee317895fb

Meeting password: IEEE (please note passwords are case sensitive)

Teleconference: Provide your phone number when you join the meeting to receive a call back. Alternatively, you can call:

+44-203-4333547  (United Kingdom)

4438636577  (United States)

2064450056  (Canada)

4006920013  (China)
Show global numbers:
https://www.tcconline.com/offSite/OffSiteController.jpf?cc=7659923550
Conference Code: 765 992 3550


Meeting number: 632 000 521

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Additional Notes:

- To add this meeting to your calendar program click the following link, or copy the link and paste it into your Web browser:
https://ciena.webex.com/ciena/j.php?MTID=mfc13bf723def2cc42b90e63cc52f8635

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

https://ciena.webex.com

 

Regards,

Pete Anslow | Senior Standards Advisor
43-51 Worship Street | London, EC2A 2DX, UK
Direct +44 2070 125535
|