[802.3_PDCC] New documents available for review
- To: STDS-802-3-PDCC@xxxxxxxxxxxxxxxxx
- Subject: [802.3_PDCC] New documents available for review
- From: "Chad Jones (cmjones)" <00000b60b3f54e8d-dmarc-request@xxxxxxxxxxxxxxxxx>
- Date: Thu, 8 Jan 2026 19:52:45 +0000
- Accept-language: en-US
- Arc-authentication-results: i=2; mx.google.com; dkim=pass header.i=@cisco.com header.s=iport01 header.b=SOLWsITk; arc=pass (i=1 spf=pass spfdomain=cisco.com dkim=pass dkdomain=cisco.com dmarc=pass fromdomain=cisco.com); spf=pass (google.com: domain of cmjones@xxxxxxxxx designates 173.37.86.75 as permitted sender) smtp.mailfrom=cmjones@xxxxxxxxx
- Arc-authentication-results: i=1; mx.microsoft.com 1; spf=pass smtp.mailfrom=cisco.com; dmarc=pass action=none header.from=cisco.com; dkim=pass header.d=cisco.com; arc=none
- Arc-message-signature: i=2; a=rsa-sha256; c=relaxed/relaxed; d=google.com; s=arc-20240605; h=mime-version:content-language:accept-language:message-id:date :thread-index:thread-topic:subject:to:from:ironport-hdrordr :ironport-data:ironport-phdr:dkim-signature; bh=kjitguVfbgGoMuerxNhsadLKYSdlNgWCVHFsYzQmnOM=; fh=PABWT8LGHrDhePZRfWvpkCptQqoBqkJfeI5kUsrpiHs=; b=UjH0ThUhRfHiNxDYs6GNqm5c0xZwkiit1BXcAO4kBKfLmgEV7ql2M7mGE2819uGl/W cblFBhwmyyj6LGhPhMOofUvTTj+P6iwazaQ77oUiGAoT4nwNXaJduRT8sYhDUn1SAZIj wUip1HAeoctWa92+XHO1xJuWXcNiW+W1o+4626CDkb0L6wtfzpnnB1Cc4FGSNrd6WNYH frR5P0vk04GiTssbvMiwvn4FGg/KZ96yOEJYXM6sGWVgFkUiYPSi2SP6IIIHZOsvWBQ4 0bxmIYJs7KDgaRCTOcreKVnDlmVHYaSx65Yc9OMwawtlfDDwwYVgz0gN4Z6lqSOp0d20 +cwg==; dara=google.com
- Arc-message-signature: i=1; a=rsa-sha256; c=relaxed/relaxed; d=microsoft.com; s=arcselector10001; h=From:Date:Subject:Message-ID:Content-Type:MIME-Version:X-MS-Exchange-AntiSpam-MessageData-ChunkCount:X-MS-Exchange-AntiSpam-MessageData-0:X-MS-Exchange-AntiSpam-MessageData-1; bh=kjitguVfbgGoMuerxNhsadLKYSdlNgWCVHFsYzQmnOM=; b=gkAE3u7o2WDS4Baj0gzV/UKjivWLZPhtC/WXa3TX1LYvqusNtkDV9oB95W5r5dQei4x8mwJtbZbArbyI2hEO09i42X+a+YrxHeRH2Fh/2glj6NLmgXJnEY/XzBcFQ/ZtQdMeTSG1musWVP3gomdNcbmUTG6G6pSznb6rCGw/uxedL1JtfqQu/EkzqrXFoTDNoFnRN/FA6bd+qZYjmoFWqbFY+Vyw7H9xzM1c3XoBdEBckSPZlHIDvViAQpu6vLBeTpMmGAoOQj1orTji0UpFBRm0ZYGN/IheYaJJuz8Jxnem1in5BEF8yzoKvbQaVCucTNpkEYBxCvEfmvRj3FF09A==
- Arc-seal: i=2; a=rsa-sha256; t=1767901971; cv=pass; d=google.com; s=arc-20240605; b=bxBOTJVauGJXl5cB5NwFz5K4l19PlvzBGsi8iF1XEdvwQjmptjAGeDVTjT+ZsJolej tH2HtH8mPgLyj1VX7/cLhDyTDV7yVMo62XI5I8A46KuFyxX3uVqyf6837VMGKpmsMpF+ qNQEs3sCwmLoZGiFcWEgGN3iwNYFQY7QrenbHI6dtYrmex3HmtXcSl4xA8jtr3WED/1r 4bt3RkbYucM6KHexFfi82lnaaK1b0WqQRLphzJhDis2N5qJs5a7n7wGZI+aCAMckZlJT oQ373S+WYzQq/VVy2garZZiOHNJEEk+DR8AD2D137KPJEjNYyx/02qJwgTHNLPRZlLXH 8sAA==
- Arc-seal: i=1; a=rsa-sha256; s=arcselector10001; d=microsoft.com; cv=none; b=pjQ/ap2j/qHBysa0Y0Lz/jmAwXDLpNZMVWS6Fg4LglQOIIvoHjcuG7MQ2Wn18Wk6iLD+2FsYG8pikwawKB42DIKmJrsY2ho49+mdwHkBavaBsYKXgLV7HzAlv8sfByUU8YTKPE7nJFN6hZ5ri+0CL6YhrSneGFqR0xQkVtAd1848f90x63SfurkQ5YRdOS9u1EHqBrg5FXIfkHELghVGGo7Ku4ORjX0Kb5EEyh7+ctBmK7bcSkuHDjkjF1fsRMqFOf5RNhfAnUNGAQ0u5oJdhVSibFVcWnLFawlDEdPe+QdbaS+Hb0ayZ9hrnUQh0CnZpMplxq9a4Ws0hJZjATqBTw==
- Delivered-to: mhonarc@xxxxxxxxxxxxxxxx
- Delivered-to: stds-802-3-PDCC@xxxxxxxxxxxxxxxxx
- Ironport-data: A9a23:DbxJt68BxezwX5lJ7VK5DrUD03+TJUtcMsCJ2f8bNWPcYEJGY0x3n WAYW2HXMq3eZjajLd8iatmy9UMOsZfVmtY3GQdvrC5EQiMRo6IpJzg2wmQcns+2BpeeJK6yx 5xGMrEsFOhtEDmE4EzrauS9xZVF/fngbqLmD+LZMTxGSwZhSSMw4TpugOdRbrRA2bBVOCvT/ 4mryyHjEAX9gWAsazpEs/jrRC5H5ZwehhtJ5jTSWtgT1LPuvyF9JI4SI6i3M0z5TuF8dsamR /zOxa2O5WjQ+REgELuNyt4XpWVTH9Y+lSDX4pZnc/DKbipq/0Te4Y5nXBYoUnq7vh3S9zxHJ HqhgrTrIeshFvWkdO3wyHC0GQkmVUFN0OevzXRSLaV/wmWeG0YAzcmCA2k9EJY19ul9OlhS6 Po4GSskMw29i9CflefTpulE3qzPLeHxN48Z/3UlxjbDALN/G9bIQr7B4plT2zJYasJmRKmFI ZFGL2AyMVKZP0wn1lQ/UPrSmM+jg3v4dTBDgFmUvqEwpWPUyWSd1ZCxbICNK4DVHJo9ckCwt mTtp1T8LTAjMOO9ywWu83O8huLsgnauMG4VPPjinhJwu3WI2mAITU1ODx7g5MGVoWWWX9NEN 1cZ4DRorKU/+QqsVNaVYvGjiGSPshhZX59bFPc3rVjXjKHV+A2eQGMDS1atdeAbiSP/fhRzv nehlNLyDjspu7qQIU9xPJ/Nxd9uEUD59VM/WBI=
- Ironport-hdrordr: A9a23:gBl0kKlG29Dbar6BxHQGNtQyol/pDfNmiWdD5ihNYBxZY6Wkfp +V7ZcmPE7P6Ar5BktApTnZAtj8fZq9z/JICPoqTMuftWjdySGVxe5ZnPDfKlHbaknDH41mpO pdmspFeafN5DFB5K6QjnjbYrMdKbK8gcaVbJLlvg9QpHZRGthdBmlCe2GmO3wzbjNrQbA+E5 2R7NdGoT2PRVQ7B/7QOlA1G8L4i5nujpzJXT4qbiRL1OCJt1yVwY+/NyLd8gYVUjtJz7tn23 PCiRbF6qKqtOz+4gPA1kfIhq4m1+fJ+59mPoihm8IVIjLjhkKDf4J6QYCPuzgzvaWG9Esqqt /RuB0tVv4DpU85P1vF4CcF6TOQkwrG2EWSi2NwRkGT5PARcQhKS/apQ7gpNicxpXBQ++2Um5 g7oF5x/6Ancy8o2h6Nq+Qhk3pR5xOJSb1Iq59Us1VPFYQZc7NftooZ4QdcF4oBBjvz7MQ9HP BpF9y03oceTbq2VQGvgoBU+q3bYl0jWhOdBkQSsM2c1DZb2Hh/0ksD3cQa2nMN7og0RZVI7/ nNdv0ArsAEcuYGKaZmQOsRS8q+DWLABRrKLWKJOFziUKUKIWjEpZL76Kg8oOuqZJsLxp0vn4 mpaiIRiUciP0b1TcGe1pxC9R7ABG27QDT208lbo4N0v7XtLYCbRRFriGpe5vdIj89vcPEzAc zDSK5+ErvmNy/0FY5Cwg35XIM6EwhubCQ8gKdJZ26z
- Ironport-phdr: A9a23:kBKsIRNQ5eecPEBtcPgl6nc2WUAX0o4cdiYP4ZYhzrVWfbvmptLpP VfU4rNmi1qaFYnY6vcRk+PNqOigQm0P55+drWoPOIJBTR4LiMga3kQgDceJBFe9LavCZC0hF 8MEX1hgl0w=
- List-help: <https://listserv.ieee.org/cgi-bin/wa?LIST=STDS-802-3-PDCC>, <mailto:LISTSERV@LISTSERV.IEEE.ORG?body=INFO%20STDS-802-3-PDCC>
- List-owner: <mailto:STDS-802-3-PDCC-request@LISTSERV.IEEE.ORG>
- List-subscribe: <mailto:STDS-802-3-PDCC-subscribe-request@LISTSERV.IEEE.ORG>
- List-unsubscribe: <mailto:STDS-802-3-PDCC-unsubscribe-request@LISTSERV.IEEE.ORG>
- Reply-to: "Chad Jones (cmjones)" <cmjones@xxxxxxxxx>
- Thread-index: AQHcgNcSEfrxm8I8fU2FQVhmb1HQ7Q==
- Thread-topic: New documents available for review
Two items
to inform the PDCC ad hoc about:
1] IEC TC 64/MT 2: IEC 60364-5-52 Committee draft
The IEC 60364-5-52: Low-voltage electrical installations Part 5-52: Selection and erection of electrical equipment Wiring
system (64/2802/CD) committee draft was circulated on 28 November 2025 with a closing date for comment of 20 March 2026. The CD to the IEC TC 64/MT 2 is uploaded to the private area at:
https://www.ieee802.org/3/ad_hoc/PDCC/private/MT2/index.html (top hyperlink).
The direction
provided to the IEEE 802.3 Category C liaison Expert is to 'Encourage referencing of ISO/IEC JTC 1/SC 25/WG 3 cabling
standards (e.g., ISO/IEC 11801), rather than duplication of requirements in IEC 60364-5-52, unless IEC TC 64/MT 2 identifies missing requirements, which preferably should be communicated to ISO/IEC JTC 1/SC 25/WG 3 for addition to their cabling standards.'.
The liaison believes this has been archived so far based on subclauses 521.2, 522.1.3, and 522.2.2 of the current IEC 60364-5-52 CD, but it would be good for the PDCC to confirm this.
This will be an agenda item at our next PDCC meeting.
[2] IEC TC 65/SC 65C/MT 63444
A new MT 63444 private page has been created:
https://www.ieee802.org/3/ad_hoc/PDCC/private/MT63444/index.html. Three documents have been uploaded behind the private area password. The comment deadline has passed for two of them, although if there were a particular concern, I suppose we could still
send a liaison letter. The IEC 61158-2-0 Industrial networks - Fieldbus specifications - Part 2-0: Physical layer specification and service definition - General concepts and terminology NWIP, however, is still open for comment. I invite input for consideration
at an upcoming PDCC meeting.
Regards,
Chad Jones
Principal Engineer, Cisco Systems
Executive Secretary, IEEE 802.3 Working Group
Chair, IEEE P802.3da Task Force
Principal, NFPA 70 CMP3