Hi Rich,

here are my veiws on the discussion and where I think a few people may not realise
the break down in costs exist for a system that covers are large area.

SDH and SONET have used an overhead structure because it saves them money. Sure
this is at the expense of data, but the leasons learnt from the past in PDH systems
make this an easy decision.

 From my perspective there is one main difference in what Ethernet has done in the
past and what it is about to do.  That's distance. Ethernet is proposing to leave
the sanctuary of a building or campus which has full time support staff ready to
fix any problem when it occurs.  As soon as you leave this environment the cost of
a problem increases exponentially, whether it be during installation, upgrade or
steady state . This lesson was learnt by the telcos when they first installed
optical amplifiers over longhaul links. The mantra then was "why waste bandwidth
with wasteful overhead". The answer was found to be "because men in trucks going
out to find the problem  is expensive!".  Take the numerous problems that arrise
with networks over a working week. Imagine the hassle if the problem is down the
road somewhere or in another country. Imagine if you are using someone elses fibre,
you have a high BER and you want to fix it. The system adminisrator will laugh in
your face if don't have the basic analytical tools at your disposal that SONET/SDH
gives.  This is where the SONET/SDH protocols save money and lots of its. That's
why they are in business with substantially less people than 15 years ago. They
have to live with the realisation of JCBs digging up cables, rainwater shorting out
connections etc. You are not talking about an ideal office situation anymore.

Imagine you are trying to place a new optical path through a system running over
several links around town. If you don't have path tagging (trail trace identifier
in SDH) in some form this will be a nightmare.

I beleive one of the reasons why ATM did not take off in the office was because the
systems people that had to use it already new Ethernet and were not prepared to
changed to something that looked overly complicated for the job. That arguement can
hold here in reverse. If you try to use an overly simplistic system to save a few
dollars and end up with a system that is very expensive to manage and run then you
will loose. If you use a system that takes on board a system that has evolved to
give the best cost / benefit ratio for that application you will win.

Another reason I see for using the SONE/SDH rates is that is will allow system
manufactures to make cheaper systems that will seamlessly work with Ethernet and
SONET/SDH at the physical layer. If you choose a different rate then thats another
chipset , another system test round and thats more money and longer time to market.
I realise this should not be the primary focus of this forum but systems do need to
be made and the easier the better.

regards

brian

Brian Russell                   Ph  +353 61 49 5745
Analog Devices                  Fax +353 61 49 5868
Limerick, Ireland               brian.russell@xxxxxxxxxx

Rich Taborek wrote:

> Andy,
>
> You're right on target with your assessment. I'll kick off a new thread with
> this note to address the contentious issue of 10 Gbps Ethernet long distance
> links. I have tried to steer the discussion on the "Deconstructing OAM&P" kicked
> off by Hon Wah Chin to focus on determining what, if any, functions of OAM&P are
> not supported by Ethernet. One strong point of view expressed over this
> reflector is that OAM&P is the ONLY way to support long links and that the rest
> of SONET/SDH is intimately tied in with OAM&P and, therefore, REQUIRED to
> support long links. I'd like to point out an old saying: "There's more than one
> way to skin a cat". It's crude, but appropriate.
>
> It is important to note that that current HSSG objectives call for support of
> Ethernet links at distances of up to 40 km. The only media I'm aware of that can
> achieve these distances in a single Ethernet link (i.e. without intermediate
> EDFAs, regens, etc.) is singlemode fiber. I'm further assuming that the fiber
> can be leased, owned, begged, borrowed or stolen as this parameter will NOT be
> part of the eventual 10 Gbps Ethernet standard. Beyond this objective, there are
> no related objectives nor sub-objectives to support ANY components of SONET/SDH
> and/or OAM&P. Any such objectives or sub-objectives must be clearly and
> concisely defined and presented to the HSSG and then voted upon by HSSG members,
> attaining 75% approval in order to be considered a formal objective.
>
>  802.3 and the HSSG is not a telco standards forum. I'd like to make it clear
> that the resoponsibility is on proponents of telco-style long distance links to
> educate the 802.3 committee on aspects of SONET/SDH and OAM&P which are lacking
> in Etherent and are absolutely required to meet HSSG objectives. What the 802.3
> committee is very good at is architecting copper and fiber-optic based links
> capable of reliably and cost effectively transporting data at distances of up to
> 10s of km. In this respect, Ethernet has no match. Current HSSG objectives will
> position Ethernet to go much faster and farther than the current Ethernet
> standard.
>
> Ethernet operates significantly differently than does SONET/SDH and OAM&P. Any
> discussion which points out differences between Ethernet and SONET/SDH/OAM&P is
> essentially irrelevant to the work of the HSSG unless the differences cannot be
> effecively acoomodated in 802.3 or elsewhere in the 802 protocol stack.
>
> Best Regards,
> Rich
>
> --
>
> Andy Leigh wrote:
>
> > One of the things that is not be accounted for is that much of SDH/SONET's
> > OAM&P information is carried as serial bits inside the transport overhead
> > bytes. These bytes are either in use by OAM&P or are "silent". Not running
> > SDH/SONET OAM&P doesn't get you back any bandwidth. It's also completely
> > independent of the stream being transported. If a OC192 links is 100%
> > congested carrying Ethernet frames, the OAM&P functions will still operate
> > perfectly. Although accounted for in the bandwidth, this stuff is really
> > "out of band" as far as the payload is concerned.
> >
> > Now, I think all of this is largely irrelevant. As far as I can see, what's
> > being debated here is using SDH/SONET engineering to achieve long distances.
> > What we're really describing is the use of SDH/SONET "repeaters" because
> > these already exist. If, instead we intend 10GBE to run as a service over a
> > telco's OC192 infrastructure, then just translate (L2 bridge) at the ends
> > and let the Telco use SDH/SONET management tools to run their
> > infrastructure, If on the other hand, we want to "pinch" chipsets and
> > hardware to make 10GBE go the distance without re-inventing the wheel, then
> > don't bother implementing SDH/SONET's bells and whistles...
> >
> > This is really not an Ethernet issue, but a Telco standards issue. I'd avoid
> > it like the plague.
> >
> > Andy Leigh
> > Senior Planning Engineer, Strategic Network Developments, New Technology
> > Tel:    +44 (0)171 765 0575
> > Fax:    +44 (0)171 765 0557
> > Pager:  01893 323488
> >
> > > -----Original Message-----
> > > From: Rich Taborek [SMTP:rtaborek@xxxxxxxxxxxxxxxx]
> > > Sent: Wednesday, August 25, 1999 1:03 AM
> > > To:   rabynum@xxxxxxxxxxx; HSSG
> > > Subject:      Re: Deconstructing OAM&P
> > >
> > >
> > > Roy Bynum wrote:
> > >
> > > > Rich,
> > > >
> > > > I believe that we are agreeing that the only level of operations and
> > > performance information
> > > > that is needed to be leveraged from the SONET/SDH system is the "Path".
> > >
> > > Roy,
> > >
> > > Given that a SONET/SDH "Path" = Ethernet "Link" according to your prior
> > > note, I believe that we
> > > agree that Ethernet already supports the gathering and transport of
> > > information required to
> > > maintain a link. I'm not sure what exactly you mean by "operations and
> > > performance information",
> > > but I believe that existing Ethernet structures can be used to gather and
> > > transport such
> > > information.
> > >
> > > > You do not want to use inband traffic bandwidth to send and receive
> > > physical layer operations and
> > > > maintenance
> > > > information.
> > >
> > > On the contrary, in Ethernet you do. The point I made in my previous note
> > > (copied below) is that
> > > Ethernet transports maintenance information in a different manner than
> > > does SONET. I believe that
> > > at 10 Gbps, the Ethernet methodology is capable of transporting
> > > maintenance information with
> > > greater efficiency than does SONET. This is due to the low frequency
> > > transport requirements of
> > > maintenance information.
> > >
> > > >  All of these things would not be as available without leveraging the
> > > SONET/SDH
> > > > technology.  Otherwise a lot of time will be spent developing new
> > > technology might delay the
> > > > deployment of 10GbE and the additional development money will have to
> > > recovered in a higher
> > > > cost interface.
> > >
> > > What new technology? Little or no time need be spent on 10 GbE maintenance
> > > and transport since the
> > > required structures are already in place. The key question posed by Hon
> > > Wah Chin in a previous note
> > > was one inquiring about the requirements of the "M" or Maintenance
> > > component of OAM&P? As a
> > > high-level requirements set, what is supported by the SONET/SDH
> > > Maintenance component which is not
> > > directly supportable via existing Ethernet management gathering or
> > > transport structures?
> > >
> > > >  Since 10GbE is going to be full duplex, the fiber or wavelength that
> > > will
> > > > transmitting, will not be same as the one that is receiving. There will
> > > be two separate "links"
> > > > between any two interface ports.
> > >
> > > Absolutely. The full duplex nature of Ethernet greatly simplifies many
> > > aspects of link management.
> > > Do you view the required full duplex nature of Ethernet as a disadvantage
> > > with respect to
> > > management?
> > >
> > > > Thank you,
> > > > Roy Bynum
> > > > MCI WorldCom
> > >
> > > Best Regards,
> > > Rich
> > >
> > > --
> > >
> > > > Rich Taborek wrote:
> > > >
> > > > > Roy Bynum wrote:
> > > > >
> > > > > > Rich,
> > > > > >
> > > > > > You are correct.  A full duplex Ethernet link is equivalent to the
> > > "Path" of a
> > > > > > SONET/SDH system.  I believe that the new term that is being used in
> > > the OIF is
> > > > > > "Trail".
> > > > > >
> > > > > > The "Line" definition within SONET/SDH are equivalent to the WAN
> > > service link.  This
> > > > > > would apply to situations where 10GbE would be put on active DWDM
> > > systems or commercial
> > > > > > SONET/SDH services.  The active "Line" information processing would
> > > be done on the
> > > > > > active DWDM or the SONET/SDH systems, not the 10GbE port or switch.
> > > The "Section"
> > > > > > function of SONET/SDH deals with physical fiber connections between
> > > DWDM or SONET/SDH
> > > > > > Line Terminating Equipment or regenerators.  Again, this would not
> > > be part of the 10GbE
> > > > > > port or switch processing.
> > > > >
> > > > > This sounds appropriate. Is a fair comparison that a "Line" is
> > > equivalent to a SONET/SDH
> > > > > transport which could encapsulate the payload of 10 Gbps Ethernet
> > > packets? Is the equipment
> > > > > that commonly converts from one to the other commonly referred to as a
> > > bridge or router? If
> > > > > it is, then this discussion is not relevant to the objectives of the
> > > HSSG. The HSSG is
> > > > > focused on developing 10 Gbps Ethernet optical links to meet distance
> > > requirements of up to
> > > > > 40 km.
> > > > >
> > > > > > Within the SONET/SDH path OAM functionality are several items that
> > > would be useful.
> > > > > > There is a path origination identification that is equivalent to the
> > > port MAC address
> > > > > > of an Ethernet port.  This allows service providers to identify the
> > > customer link
> > > > > > without looking at any of the data.  It will also allow MAC to MAC
> > > link identification
> > > > > > without impacting any of the active traffic.  There is a bit
> > > interleave parity function
> > > > > > that can be used to detect bit errors that also does not impact
> > > active traffic.  There
> > > > > > is a status indicator that can send some status and link received
> > > error performance
> > > > > > information back to the far end port, again without impacting the
> > > active traffic.
> > > > > > There are other items that might also be used.  I will be going over
> > > these at the Kent
> > > > > > meeting.
> > > > >
> > > > > In native Ethernet, there is no need to burden the Physical layer with
> > > overhead
> > > > > specifically allocated to configuration or link maintenance and its
> > > corresponding
> > > > > management. In general, packet-based LANs and SAN, including Ethernet,
> > > meet configuration,
> > > > > link maintenance and general management requirements by architecting
> > > measurement facilities
> > > > > at the Physical layer and Transport facilities at the MAC layer and
> > > above. The reasoning
> > > > > being that since optical links typically operate at link BER rates
> > > much lower than 10^-12,
> > > > > and that configuration and other management requests are very
> > > infrequent. Therefore, a more
> > > > > efficient use of link bandwidth is to send management packets on an
> > > as-needed rather than
> > > > > synchronous basis. This to me "impacts the active traffic" much less
> > > than does a
> > > > > synchronous management transport alternative.
> > > > >
> > > > > Please also note the protocol danger of reporting management (e.g.
> > > error) information using
> > > > > the same link which recognized the error, and of using the same and
> > > loop/ring protocol to
> > > > > do so. Much confusion can result, akin to playing the game of
> > > "telephone", with a group of
> > > > > folks arranged in a circle whispering in each others ear. The original
> > > transmitter of the
> > > > > message will typically and eventually receive a corrupted copy of the
> > > original message.
> > > > > This problem is solved by employing switched architectures and higher
> > > level-based protocol
> > > > > transports.
> > >
> > > -------------------------------------------------------------
> > > Richard Taborek Sr.    Tel: 650 210 8800 x101 or 408 370 9233
> > > Principal Architect         Fax: 650 940 1898 or 408 374 3645
> > > Transcendata, Inc.           Email: rtaborek@xxxxxxxxxxxxxxxx
> > > 1029 Corporation Way           http://www.transcendata.com
> > > Palo Alto, CA 94303-4305    Alt email: rtaborek@xxxxxxxxxxxxx
> > >
>
> -------------------------------------------------------------
> Richard Taborek Sr.    Tel: 650 210 8800 x101 or 408 370 9233
> Principal Architect         Fax: 650 940 1898 or 408 374 3645
> Transcendata, Inc.           Email: rtaborek@xxxxxxxxxxxxxxxx
> 1029 Corporation Way             http://www.transcendata.com
> Palo Alto, CA 94303-4305    Alt email: rtaborek@xxxxxxxxxxxxx

--