Jorge, Duane, and all,

I started a new thread since I wasn't quite sure where to insert my reply.  Let me start with the drawing with multiple FCUs question that you proposed.

[Description: cid:image001.jpg@01CDECF9.0BFEEB40]

The assumption with multiple FCUs is that you are shaping 3 pipes (A, B, & C) inside the 10G EPON downstream.  If you make that sum of those 3 less than the maximum rate, you can send them down the PON at the same with a single packet of jitter.  The total bandwidth of the downstream is a constant since it is the sum of the 3 constants.

For Multiple sub-pipes: Total BW = A + B + C  (Sum of 3 Constants)

In the case of MMP, you have a single pipe with a changing data rate based on the destination.  The data rate from the OLT is not a constant or the sum of 3 pipes.  It is going up and down based on the destination.  A single shaping bucket is used but the debit for the reverse leaky bucket is different based on destination.  The total bandwidth equation is an OR.

For MMP: Total BW = A | B | C.  (The total bandwidth or maximum bandwidth is based on the traffic)


I hope that helps.  I will send a separate email on the other issues related to the MAC layer solution.

Thanks,
Ed...

[Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: cid:image009.jpg@01CD505E.7B800DB0]

Edward Boyd | Sr Technical Director
Broadcom Corporation | (O) 707-792-9008 | (M) 707-478-1146

[Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: image005]<http://www.linkedin.com/company/broadcom>[Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: image002]<http://twitter.com/#!/broadcom>[Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: image003]<https://www.facebook.com/Broadcom>[Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: image004]<https://plus.google.com/109188783526874806673/posts#109188783526874806673/posts>[Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: image006]<https://www.youtube.com/user/BroadcomCorporation>[Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: image008]<http://blog.broadcom.com/>[Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: Description: image007]<http://broadcom.com/>