Re: [STDS-802-11-TGM] REVmf/D2.0 CID 1341
--- This message came from the IEEE 802.11 Task Group M Technical Reflector ---
Mike,
Those are in SEC.
Mark
-----Original Message-----
From: Jouni Malinen <jkmalinen@xxxxxxxxx>
Sent: Thursday, 14 May, 2026 12:26
To: STDS-802-11-TGM@xxxxxxxxxxxxxxxxx
Subject: [STDS-802-11-TGM] REVmf/D2.0 CID 1341
--- This message came from the IEEE 802.11 Task Group M Technical Reflector ---
We discussed CID 1341 and 1342 today and marked 1341 ready for motion while assigning 1342 to me for additional work. Could we please reassign 1341 to me as well and revert it from being ready for motion?
I had not realized that these are in the description of the Authenticator state machine for the rules when the EAPOLKeyReceived variable is set to true. Most of the text in that location does not belong here and the parts related to these two comments is completely wrong since there is no key index being indicated at all in EAPOL-Key frames that an Authenticator would process. In other words, the referenced text needs to be deleted instead of the should-to-shall change.
The only thing that is actually of importance here is that the state machine assume this variable is set to true only if the replay counter in the received frame is valid. That only relevant item is completely missing here and I can fix that while addressing these comments.
- Jouni
_______________________________________________________________________________
IF YOU WISH to be Removed from this reflector, PLEASE DO NOT send your request to this CLOSED reflector. We use this valuable tool to communicate on the issues at hand.
SELF SERVICE OPTION:
Point your Browser to - http://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGM and then amend your subscription on the form provided. If you require removal from the reflector press the LEAVE button.
Further information can be found at: http://www.ieee802.org/11/Email_Subscribe.html
_______________________________________________________________________________
_______________________________________________________________________________
IF YOU WISH to be Removed from this reflector, PLEASE DO NOT send your request to this
CLOSED reflector. We use this valuable tool to communicate on the issues at hand.
SELF SERVICE OPTION:
Point your Browser to - http://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGM and
then amend your subscription on the form provided. If you require removal from the reflector
press the LEAVE button.
Further information can be found at: http://www.ieee802.org/11/Email_Subscribe.html
_______________________________________________________________________________