Re: [802.3_4PPOE] Detection cleared by SISM state diagrams



Hi Lennart,

Introducing a state before ENTRY_PRI and ENTRY_SEC will do the same thing.  I will support either option.  I will defer to you as to which option you think looks better.
 
Thanks,
Chris

-----Original Message-----
From: Lennart Yseboodt [mailto:lennartyseboodt@xxxxxxxxx] 
Sent: Friday, October 13, 2017 2:45 AM
To: Chris Bullock (bullock) <bullock@xxxxxxxxx>; STDS-802-3-4PPOE@xxxxxxxxxxxxxxxxx
Subject: Re: [802.3_4PPOE] Detection cleared by SISM state diagrams

Hi Chris,

I like the concept to avoid continuously executing this block of code for a part of the state diagram that should be sleeping.

We can move it to SISM_START, but editorially that moves another chunk of text to a diagram that is already very full.

What if we introduce a state before ENTRY_PRI with no actions, and that exists to ENTRY_PRI when 'sism' ?

Does the same thing I think...

Lennart

On Wed, 2017-10-11 at 03:15 +0000, Chris Bullock (bullock) wrote:
> We could take all of the assignments that are currently in the 
> ENTRY_PRI and ENTRY_SEC states, and move them to the SISM_START state.
>  
> Thanks,
> Chris
>  
> From: Heath Stewart [mailto:00000855853231d4-dmarc-request@xxxxxxxx]
> Sent: Monday, October 09, 2017 11:23 AM
> To: STDS-802-3-4PPOE@xxxxxxxxxxxxxxxxx
> Subject: Re: [802.3_4PPOE] Detection cleared by SISM state diagrams
>  
> Change to
> if (sism & (CC_DET_SEQ != 2)) then
>  
> -Heath
>  
> On Mon, Oct 9, 2017 at 2:59 AM, Lennart Yseboodt <lennartyseboodt@gma 
> il.com> wrote:
> Hi,
>  
> As of this cycle we have included the SISM state diagrams in our 
> simulation.
>  
> When a single-signature is connected, ENTRY_PRI (and SEC) are executed 
> continuously because "!sism" is TRUE.
> 
>  
> This has the effect to force sig_pri (and sig_sec) to 'invalid'
> continuously, thereby breaking the main state diagram.
> I don't know why that statement is there.
>  
> Can we remove the IF statement and sig_pri <= invalid ?
>  
> Kind regards,
>  
> Lennart
> 
> 
>  
> --
> Heath Stewart
> Design Center Manager, Mixed Signal
> 
> Office   (805) 560-7658
> Mobile  (805) 895-0499
> Websites      analog.com, linear.com
> 
> Linear Technology is now part of Analog Devices.  Learn more.
>