Hi Bo,

 

Kindly help to update SP #1a of PS MAC SP Set #8 as below:

 

SP #1a:

       For Active Tx and bi-static Backscatter non-AP AMP STAs, the length indication (either the Length of Data Field in the AMP-SIG field or the Frame Body Length field in the MAC Header field) is:

    • If the data rate is 250 Kbps:
      • Field values x= 0 to 31 correspond to (x+1) = 1 to 32 octets, values x= 32 to 47 correspond to 32+2(x-31) = 34 to 64 octets, and values x= 48 to 63 correspond to 64+4(x-47) = 68 to 128 octets
    • If the data rate is 1 or 4 Mbps:
      • Field values x= 0 to 31 correspond to 2(x+1) = 2 to 64 octets, values x= 32 to 47 correspond to 64+4(x-31) = 68 to 128 octets, and values x= 48 to 63 correspond to 128+8(x-47) = 136 to 256 octets

 

I would also like to request to defer SP#2 and SP#3 to a later date; I am working on the corresponding PDT to give the group a sense of the spec change that may be involved to support the 2 SPs.

 

Best Regards,

Rojan Chitrakar